-
-
Notifications
You must be signed in to change notification settings - Fork 24
1.4.0
Matthias Mailänder edited this page Feb 17, 2023
·
3 revisions
- Added support for the mMass
.msd
MALDI file format. ChemClipse#911 - Added a filter to enable setting the selected scan via a process method. ChemClipse#915
- Added sample metadata for MALDI-TOF MS spectra. ChemClipse#914
- Added external quantitation reference entry to area % report. ChemClipse#922
- Added alkane calibration standard matching by CAS or IUPAC name. ChemClipse#923
- Fixed Peak/Scan List not updating after hidden in the background. ChemClipse#913, ChemClipse#920
- Fixed Targets not updating after hidden in the background. ChemClipse#926, ChemClipse#930, ChemClipse#932
- Fixed Scan Table not updating after hidden in the background. ChemClipse#927, ChemClipse#930
- Fixed Scan Chart not updating after hidden in the background. ChemClipse#929, ChemClipse#930
- Fixed Scan Comparison not updating after hidden in the background. ChemClipse#931
- Fixed undoable ↩️ filters resetting the chart range. ChemClipse#917
- Fixed Peak Traces not updating after hidden in the background. ChemClipse#924
- Fixed MALDI ion table performance when loading high-resolution data. ChemClipse#910
- Fixed bright yellow 🟨 background colors. ChemClipse#928
- Fixed AnIML converter reading unrelated files and crashing. OpenChrom#215
- Added softer background colors to ratio and peak status texts. OpenChrom#207
- Added quantification fields to the
.csv
report builder. OpenChrom#208 - Added undo/redo support for Denoising ChemClipse#903
- Added performance improvements to importing MALDI-TOF MS data. ChemClipse#904
- Added performance improvements when MSD datebases are not available. ChemClipse#904
- Added a delimiter option to the CSV chromatogram import. ChemClipse#909
- Fixed a compatibility problem in GC-FID
.animl
export. OpenChrom#209 - Fixed chromatogram not refreshing when changing label settings. ChemClipse#905
- Fixed chromatogram reference dropdown box not updating labels. ChemClipse#906
- Fixed performance problems when
.msl
andnist.db
identifiers are not configured. ChemClipse#904 - Fixed a resource leak when using Peak Review/Detection wizards. OpenChrom#211
- Removed the peak filter setting from the Bruker flex plugin.
- Added Peak Review [Template] and [Direct] modus for HPLC-DAD and UV/Vis OpenChrom#198
- Added column width/order saving to Peak Review UI OpenChrom#204
- Added plotting hints to the
animl
exporters. OpenChrom#206 - Added undo/redo for peak/scan deletion. ChemClipse#886
- Added a user configurable limit for undo actions. ChemClipse#892
- Added a method to enable the rasterization of HPLC-DAD data. ChemClipse#899
- Fixed required fields missing in the
.animl
exporters. OpenChrom#205 - Fixed an update loop in profile mass spectrum editor. ChemClipse#881
- Fixed chromatogram not getting set dirty when quantifying peaks. ChemClipse#882
- Fixed editor extend Y label mentioning the wrong axis. ChemClipse#883
- Fixed chromatogram chart wizards not inheriting the extend Y option. ChemClipse#884
- Fixed link peak/scan list with editor using the wrong icon. ChemClipse#890 ChemClipse#900
- Fixed database editor button not toggling their toolbars. ChemClipse#891
- Fixed retention index to retention time mapping sometimes failing. ChemClipse#898
- Fixed a performance problem with the Molecule view. ChemClipse#888
- Fixed
*.cal
editor not being marked as dirty when changes were made. ChemClipse#897 - Fixed Scan Remover Filter sometimes failing. ChemClipse#902
- Added a mass spectral hash (splash) converter. OpenChrom#107
- Added full scans to
.animl
MS chromatograms. OpenChrom#197 - Added additional fields to the CSV report. OpenChrom#196
- Added softer background colors to quantitation and targets list. ChemClipse#870
- Fixed chromatogram editor not being marked as changed consistently. ChemClipse#879, ChemClipse#875, ChemClipse#873
- Fixed database editor not being marked as changed. ChemClipse#877
- Fixed a crash in the quantitation report. ChemClipse#878
- Fixed mass spectrum editor being marked as dirty when there are no changes. ChemClipse#876
- Peak Detector [Template]
- Added a button to adjust the start/stop retention time of all listed position markers at once. OpenChrom#181
- Removed the necessity to press the "Save" 💾 button when changing values. OpenChrom#180
- Added a proper table representation in the settings to the
- Peak Identifier [Template] OpenChrom#182
- Trace Ratio Classifier OpenChrom#183
- Time Ratio Classifier OpenChrom#184
- Quant Ratio Classifier OpenChrom#185
- Added a peak "Named Traces" export for import in the chromatogram overlay. OpenChrom#190
- Added a user configurable
.csv
Report. OpenChrom#191 - Fixed
.pdf
report- for HPLC-DAD chromatograms with negative intensities. OpenChrom#193
- printing empty tables when there are no peaks. OpenChrom#193
- Added optional processor settings to the
.pdf
report header. OpenChrom#194 - Fixed HPLC-DAD
.ocb
chromatograms not importing peaks. ChemClipse#858 - Added a rename 🏷️ description button to the process method editor. ChemClipse#861
- Added a penalty calculation view to visualize the parameters. ChemClipse#863
- Fixed batch job not being marked with
*
when modifying entries. ChemClipse#868
- Added Thermo GC-FID (
*.raw
) import converter. - Fixed
.mzML
standards compliance problems. ChemClipse#855
- Fixed
.mzML
standards compliance problems. ChemClipse#852 - Fixed separation column resetting. ChemClipse#851
- Fixed
.animl
chromatograms not getting detected. OpenChrom#177 - Added default icons to the quick access toolbar. ChemClipse#849
- Added icons to the toolbar visibility switches. ChemClipse#847
- Added a date hint for the Shimadzu
*.qgd
files as access time.
- Fixed
.mzML
standards compliance problems. ChemClipse#844, ChemClipse#845 - Fixed
File
→Import
→Chromatogram Import
ChemClipse#841 - Fixed quantitation results showing a concentration of 0 when no measurement was done. ChemClipse#840
- Fixed Chromtech (
*.dat
) files showing the wrong month. - Added the CAS number to the peak quantitation list ChemClipse#840
- Added support for
.dx
FT-IR data. ChemClipse#843 - Added an option to not sort the extracted traces. ChemClipse#839
- Added a proprietary vendor file batch convert dialog.
- Fixed retention index being exported twice in the CSV mass spectrum identification list. ChemClipse#836
- Fixed 🔴 decorations failing for the search case-sensitive button. ChemClipse#832
- Fixed special chars like
[
or)
which can be found in complex IUPAC names, disturbing the peak list search. ChemClipse#831 - Fixed cryptic string validation messages being presented to the end user. ChemClipse#828
- Fixed the peak scan list not updating on macOS when integrating. ChemClipse#822
- Fixed FT-IR transmission spectra showing odd values when no absorption was measured. ChemClipse#821
- Fixed peak detector UI methods freezing when the ion was not found in the chromatogram. OpenChrom#174
- Fixed NMR digital filter removal and phase correction. OpenChrom#171
- Fixed Roche LightCycler showing duplicated color compensated data in some cases.
- Fixed Thermo Nicolet
*.spc
,*.spa
FT-IR converter failing to detect and open data and import original measurement date. - Fixed importing the Thermo Atlas files in edge cases.
- Added support for MassHunter QTOF data.
- Added a message when a parameter requires not to be left empty. ChemClipse#835
- Added a tabular log viewer with color coded lines for
⚠️ warnings and ❗ errors, as well as ℹ️ status lines and ✔️ success messages. ChemClipse#827 - Added a position marker 🔺 in the chromatogram editor retention time axis. ChemClipse#825 SWTChart#278
- Added an option to make axis lines optional. SWTChart#274
- Added a switch between transmission and absorbance in FT-IR. OpenChrom#164 ChemClipse#811
- Added support to filter per wavelength in HPLC-DAD 1st derivative peak detection. ChemClipse#801
- Added a help text to the molecule view when no target is selected. ChemClipse#806
- Added a new icon for targets, scan table and peak details. ChemClipse#815
- Added a system setting to skip validation for edge cases. ChemClipse#819
- Added an option to make axis lines optional. SWTChart#274
- Added support for Thermo Galactic Grams
.spc
FT-IR transmission spectra. - Fixed legends for inverted axes. SWTChart#276
- Fixed separation column handling. ChemClipse#816
- Fixed the Y axis for FT-IR. ChemClipse#812
- Fixed scans and peaks overlapping in the Peak Scan List. ChemClipse#817/ChemClipse#818
- Fixed the custom size chart exports being blank. SWTChart#273
- Fixed retention index map (from
.cal
) could not be found. ChemClipse#804 - Added an SRI instruments PeakSimple GC-FID converter.
- Added an option to filter low intensity scans for Thermo
.raw
files.
- Fixed peak review crashing when the boundary is too wide. OpenChrom#143
- Added a new
Dynamic Offset
option to the peak review UI. OpenChrom#144 - Added new hotkey keypad + and - to zoom in/out with configurable offset in the settings page to the peak review UI. OpenChrom#160 OpenChrom#161
- Added read/write support for
.animl
🐯 mass spectra. https://github.com/OpenChrom/openchrom/pull/158 - Added title case to the threshold combobox labels. ChemClipse#793
- Fixed peak traces part not unloading when closing a chromatogram editor. ChemClipse#794
- Fixed peak traces not being disabled when GC-FID data is loaded. ChemClipse#794
- Added support for delete visible/hidden series menu entries when loading HPLC-DAD files. ChemClipse#794
- Fixed peak traces view not updating when the peak has been modified. ChemClipse#794
- Fixed Thermo Atlas GC-FID import when runs were stopped manually.
- Added copy traces (wavelengths) to the scan chart view. ChemClipse#795
- Added copy traces (wavelengths) to the scan table view. ChemClipse#796
- Added support for
MM
(manual, manual) HPLC-DAD peak detection. ChemClipse#797 - Fixed area % filter failing to load settings and clarified labels. ChemClipse#802
- Fixed borders when exporting bitmaps on Windows. SWTChart#271
- Added a chart menu entry to set a specific X/Y range. SWTChart#272
- Added grouping by start and stop retention in the peak template report. OpenChrom#159
- Fixed PCR plate chart conflicting when opening multiple files. ChemClipse#766
- Added a button to toggle zoom for the heatmap when looking at HPLC-DAD data. ChemClipse#768
- Added a missing settings page for the first derivative peak detector when applying it to HPLC-DAD data. ChemClipse#770
- Added
Save As...
to the process method editor. ChemClipse#773 - Fixed ZeroSet not working for HPLC-DAD
*.ocb
files. ChemClipse#775 - Added support for charset selection when importing
*.msl
,*.msp
files. ChemClipse#789 - Fixed chromatogram overlay mirror setting the wrong item in the combobox if the description was the same for all listed chromatograms.ChemClipse#790
- Fixed method editor not being marked as changed when editing header fields ChemClipse#791
- Fixed Thermo Atlas FID intensities.
- Fixed Thermo Atlas file names.
- Added an option to the Bitmap export for specific sizes. SWTChart#271
- Added a chart menu entry to set a specific X/Y range. SWTChart#272
- Fixed antlr/TokenStream error when parsing directories for JCAMP-DX NMR files.
- Added standard assignment by traces to aid setting deuterated standards. OpenChrom#154
- Added labels to the ion rounding system setting. ChemClipse#760
- Added the number of files to the batch process editor ChemClipse#763
- Removed
ALL CAPS
settings from the 1st derivative peak detection settings dialog. ChemClipse#756 - Fixed existing files not being listed in the process method
Save As...
dialog. ChemClipse#773
- Replaced window combo boxes with validated integer. ChemClipse#737
- Replaced segment width combo boxes with integer fields. ChemClipse#753
- Fixed methods being marked as modified* by default. ChemClipse#747
- Fixed PCA perspective freezing when it is started on first run. ChemClipse#749
- Fixed referenced chromatogram mapping to the master in the Chromatogram Overlay. ChemClipse#752
- Added
Save As...
to the process method editor. ChemClipse#758 - Added labels to the Ion Round process setting. ChemClipse#760
- Added support for MSD chromatograms in
.animl
🐯 format. OpenChrom#140 - Added support for Thermo Atlas GC-FID files.
- Removed ALL CAPS settings from the 1st derivative peak detection settings dialog. ChemClipse#756
- Added read/write support for
.animl
🐯 FID chromatograms. OpenChrom#134 - Added a tabular UI for the Template Report OpenChrom#137/ChemClipse#735
- Added column selection to the 📋 Template Report OpenChrom#139
- Fixed chromatograms not being marked as dirty after changes to it. ChemClipse#730
- Fixed chart label descriptions not updating when data was mapped. ChemClipse#732/SWTChart#266
- Fixed total intensity chromatogram for DAD data. ChemClipse#719
- Fixed Waters file name and index not getting displayed
- Added automatic zoom 🔎 out when changing back to TIC. ChemClipse#719
- Added automatic zoom reset after zero setting. ChemClipse#719
- Added a sort 🔤 button to the batch process. ChemClipse#738/ChemClipse#739
- Added a
Delete All
❌ button to the process method. ChemClipse#740 - Added a dialog to import multiple reference chromatograms at once. ChemClipse#741
- Added an option to rename the chromatogram header when switching to a reference ChemClipse#742
- Added an icon to the chart legend change visibility button. SWTChart#267
- Added the possibility to select single Waters _func00x files.
- Fixed performance problems with extracted wavelength chromatograms (XWC). ChemClipse#694
- Fixed an error that delayed application startup. ChemClipse#696
- Enabled tooltips by default in the PCR chart. ChemClipse#698
- Moved all views but the charts from the PCR perspective into the background. ChemClipse#698
- Fixed
Command
modifier not working on macOS. ChemClipse#709 SWTChart#258 - Fixed newly opened files being marked as changed. ChemClipse#703
- Fixed editors spawned from data explorer not getting focus. ChemClipse#703
- Added a Max (Spectrum) Plot Chromatogram for HPLC-DAD data. ChemClipse#706
- Fixed HPLC-DAD
.ocb
files not opening. ChemClipse#708 - Added an option to save the default status of method and references toolbar elements. ChemClipse#710
- Improved performance of the chromatogram heatmap. ChemClipse#712
- Added a perspective for HPLC-DAD where the wavelength is selected from a heatmap. ChemClipse#712
- Fixed dropdown box in the showing irrelevant chromatogram overlay types. ChemClipse#713/ChemClipse#714
- Added support for compound information file (
*.CID
) supplied by NIST databases. ChemClipse#715 - Added support for reading chemical structure information from
*.MOL
files as supplied by NIST AMDIS. ChemClipse#716 - Added a
Cancel
button into the process method resume wizard. ChemClipse#717 - Fixed mass spectrum remaining in the comparison scan window after the editor was closed. ChemClipse#723
- Fixed lines marked as invisible in charts, triggering 👻 tooltips. SWTChart#256
- Added support for
.mzMLb
files OpenChrom#125 - Improved performance of the Data Explorer when working with larger
.*mz
files ChemClipse#689 OpenChrom#127 - Fixed an application freeze when loading Agilent sequence files.
- Added support for setting peak detection settings in process methods. OpenChrom#124
- Added support for setting the review export in process methods. OpenChrom#123
- Added an option to enable/disable to export the optimized range when exporting peak review files. OpenChrom#122
- Fixed the dot in
.txt
missing when exporting trace or time ratios. OpenChrom#121 - Added support for multidimensional data in
CDF
format OpenChrom#119 - Added support for setting the ion round method and retention index QC in process methods. ChemClipse#684
- Added a peak filter to add a classification to peaks and to skip peaks that contain at least one classification already ChemClipse#683
- Added a filter to remove peak classifiers. ChemClipse#682
- Added an option to choose from regular expression or simpler string comparison in the peak classifier. ChemClipse#681
- Added a toolbar button to show/hide grid lines in charts. ChemClipse#680
- Added a filter to split a chromatogram into a SCAN and SIM reference chromatogram ChemClipse#679
- Added per channel chromatogram subtraction for MS and DAD data. ChemClipse#677
- Added initial support for reading .nmrML fid data. OpenChrom#118
- Improved detection speed for
.msl
.msp
.xlsx
.jdx
.jdl
files. ChemClipse#675 - Added per well coloring to the PCR Well Chart. ChemClipse#673
- Added a slider to the
.ocb
compression settings. ChemClipse#671 - Synchronized the channel across view when selecting one in the PCR editor. ChemClipse#667
- Added options on how to label PCR data by coordinate, sample name or both. ChemClipse#662
- Remember the last location when saving PCR plates. ChemClipse#665
- Added inverse heatmap display for multidimensional GC data. ChemClipse#663
- Added a limit of max 10 M data points to the heatmap. ChemClipse#660
- Added automatic distinguishing between chromatograms and mass spectra for
.mzXML
files. ChemClipse#658 - Added an overlay for MALDI-TOF MS spectra. ChemClipse#657
- Added support for GC-IMS data. ChemClipse#659
- Added a converter for G.A.S
*.mea
files. - Added an option for to enforce DAD data when clicking on Agilent files.
- Fixed lignin ratio calculation when peaks were identified against a database beforehand. ChemClipse#656
- Added write support for
.mzML
chromatograms. ChemClipse#654 - Added performance measurements to the
Data Explorer
into the log files. ChemClipse#655 - Added number validation to the Savitzky-Golay filter width. ChemClipse#653
- Added an
Aa
icon for case-sensitive search. ChemClipse#646 - Fixed synonyms not getting updated when identification targets are set ChemClipse#651
- Fixed a crash when loading compressed
.mzML
files. ChemClipse#650 - Added support for
.mzData
MALDI-TOF MS files. ChemClipse#648 - Added write support for
.mzData
chromatograms. ChemClipse#642 - Added support for exporting
mzXML
chromatogram with optional value compression. ChemClipse#640/ChemClipse#637 - Fixed minimum limit of
1
being disallowed high/low pass peak/ion filter. ChemClipse#639/ChemClipse#638 - Added a button to switch visibility of all chart legend entries at once. SWTChart#251
- Added an icon for the sort table button in the chart legend. SWTChart#248
- Added support for the
.hsa
file format, which contains HPLC-DAD data.
- Added support for color compensated real-time PCR data and corrected the X axis label for PCR charts. ChemClipse#625
- Improved support for meta methods. ChemClipse#635
- Fixed the zeroset to use the global minimum signal for WSD chromatograms. ChemClipse#632
- Added a
delete peak
button to the peak/scan list. ChemClipse#628
- Added support for .gaml files containing LC/GC-CSD/MSD/WSD, NMR or FT-IR data. OpenChrom#113
- Fixed the unit for IR spectra. ChemClipse#621
- Enabled the
Molecule
view by default. ChemClipse#619 - Improved editing of ISTD and classifiers in the
Peak/Scan List
. ChemClipse#622 - Fixed potential crashes in the CSV reader (MSD). ChemClipse#624
- Fixed peak integration for WSD chromatograms. ChemClipse#620
- Fixed the NMR perspective not resetting properly. OpenChrom#110
- Added read support for the
.mz5
file format. OpenChrom#111 - Fixed the molecule view being disabled by default. ChemClipse#619
- Added support for profiles inside process methods. ChemClipse#617
- Fixed ruler mode in the chromatogram overlay disturbing the other modes. ChemClipse#616
- Added chromatogram overlay hotkeys to the integrated help system. ChemClipse#613
- Added a right-click menu entry to refresh the
Data Explorer
. ChemClipse#610 - Added icons for
Data Explorer
file/folder open with right-click actions. ChemClipse#610 - Added support for HPLC-DAD instrument files in the
.arw
format. ChemClipse#611 - Fixed shifting Y-axis in a chromatogram overlay changes the x-axis units. ChemClipse#606/OpenChrom#109
- Increased the limits for highest and lowest setting on the High/Low Pass Peaks filter. ChemClipse#605
- Increased the limits for highest and lowest setting on the High/Low Pass Ions filter. ChemClipse#604
- Added support to remember the table width in the user preferences. ChemClipse#596
- Added a
Close
andClose All
entry to theFile
menu. ChemClipse#600 - Fixed
Project Explorer
being used twice. Renamed toWorkspace
. ChemClipse#597 - Fixed
Welcome
andLogging
perspectives not resetting properly ChemClipse#598 - Added a dialog reminding the user that a restart is required when installing assets. ChemClipse#595
- Added support to reset mappings in the
Chromatogram Overlay
. SWTChart#235