Notifications
You must be signed in to change notification settings - Fork 131
Items ConceptZone
ggodart edited this page Jan 1, 2021
·
1 revision
See original
None
This is a MisterHouse module for handling input from the Concept alarm system made by Inner Range. Details on the alarm system can be found at https://www.innerrange.com/ At the moment the model expects the alarm system to be connected to one of the serial ports on the computer. The computer, which looks like a printer to the alarm system, will scan the lines received looking for key strings and take the appropriate action if one is found.
The module will log everything recieved to; {data_dir}/logs/ConceptYYYY_MM.log
where YYYY is the year and MM is the month
This module is based on the DSC_Alarm module writen by Danal Estes
- 20020601 - Nick Maddock - Creation day
- 20020609 - Nick Maddock - Tiedied up a lot of things
- 20020609 - Nick Maddock - Put handling to occupied in
- 20020609 - Nick Maddock - Put in change of logs every day
- Handler for over alarm things
- Migrate to a better communication standard
- Handling for alarm auxiliaries
- Activation, Deactivation (???) of the alarm system
METHODS
Method | Description |
---|---|
serial_startup |
Create serial port(s) according to mh.ini Register hooks if any ports created. |
Concept_serial_port = COMx # The serial port alarm system is on /dev/sttyx
Concept_baudrate = [1200, 4800, 9600] # The baudrate of the port
debug = Concept # Will turn debugging information on if present
None
None
None
Method | Description |
---|---|
new |
Creates a new object of one of the alarm types. Takes: Class - The object class, well it's automatically passed Zone Name - The zone name associated with this object Idle Timer - The amount of time the object should be restored for before it is considered to be restored, this is for occupancy on the motion sensors |
zone_name |
Returns the Zone Name that the object is interested in this routine is used by the parent object so that it can find the correct instance when it receives and alarm or restore |
alarm |
Called by the parent function when an alarm is received for this object. This function should change the state to alarmed and stop the timer if it is running |
restore |
Called by the parent object when a restore is received for this input, This should change the state to not alarmed and start a timer to clear the occupied flag |
timer_expired |
This routine is run when the timer expires it rests the occupied flag to indicate that the room isn't occupied any longer |
state |
returns the current state of the zone object |
occupied |
returns the current occupied state of the zone |
None
None