HBHE stuck ADC filter #44955
HBHE stuck ADC filter #44955
Conversation
cms-bot internal usage |
+code-checks Logs: https://cmssdt.cern.ch/SDT/code-checks/cms-sw-PR-44955/40228
|
A new Pull Request was created by @abdoulline for master. It involves the following packages:
@jfernan2, @mandrenguyen, @cmsbuild can you please review it and eventually sign? Thanks. cms-bot commands are listed here |
please test |
type hcal |
+1 Summary: https://cmssdt.cern.ch/SDT/jenkins-artifacts/pull-request-integration/PR-331fa1/39355/summary.html Comparison SummarySummary:
|
+1 |
This pull request is fully signed and it will be integrated in one of the next master IBs (tests are also fine). This pull request will now be reviewed by the release team before it's merged. @sextonkennedy, @antoniovilela, @rappoccio (and backports should be raised in the release meeting by the corresponding L2) |
+1 |
PR description:
A rare issue may happen to HCAL RAW data: non-rotating capacitors (capId) of FE chips, which symptom is "stuck" (all the same, high-level) ADC counts in all 8 TS. _
Most of such cases are filtered out (per affected readout) by the unpacker,
if there is a corresponding error flag set by BE.
But it was found in Run3 data that there were very rare occurrences of the issue without the error flag set.
This filter is intended for selecting/scanning already taken data for further studies.
In parallel, (a development of) the relevant filtering at the entrance of the HCAL reconstruction is being considered.
PR validation:
NB: this is a standalone filter not included in any wf.
Tested by simple injection of manually altered Digi (to exactly mimic stuck ADC data):
%MSG-w HBHEstuckADCfilter: HBHEstuckADCfilter:stuckADCfilter 12-May-2024 07:49:34 CEST Run: 1 Event: 1
stuck ADC = 111 in (HE 22,39,4)
Output file (events_list_stuckADC.txt) contains a simple list of affected events in the from run:lumi:event