Skip to content

Vesuvio homing sequence

John Holt edited this page Oct 14, 2020 · 4 revisions

Wiki > The Backend System > Specific Device IOC Motor IOCs > McLennan > Vesuvio homing sequence

There is a special homing sequence for Veuvio because it doesn't work this is until ticket 5739 is done

Homing left and right foils

Do not home in ibex Drive the foil with mclennan front panel to appropriate limit (upper limit for left foil, lower limit for right foil). Goto the motor details page in ibex

  • Check the led is red next to the appropriate limit to indicate it is on the limit switch

  • in the calibration section:

  • Don’t change the Off: value

  • Set calibration to frozen

  • Push “set”

  • Type 0 into the Move Abs Dial column (the corresponding “user” column value should update automatically)

  • Push “use”

  • (it is ok to leave calibration as frozen – no need to set back to variable)

The offset value in the Calibration section should not get altered by this procedure, as the dial position is zero both the user readback value and the offset should be the same and reflect the position you currently expect (42.5 right, -41.75 left).

To test you could drive to the other limit and back etc. Whenever you drive to the appropriate homing limit the Dial value should end up being 0 (or very close to)

Note: Ibex stores the “offset” and high/low soft limits as part of the configuration, so if these are changed on the motor details they would also need to be changed on the config page or they will get reset on an ibex restart. I think I have adjusted the left ones to work on the above procedure, but we can check later.

Clone this wiki locally