Skip to content

Commit

Permalink
[zh] Resync concepts pages for services-networking\dual-stack.md
Browse files Browse the repository at this point in the history
* Resync with english version in 'Dual-stack docs correction kubernetes#26386'

* Update in 'administer-cluster\safely-drain-node.md' kubernetes#25996

* Fix git rebase in services-networking\dual-stack.md

Signed-off-by: ydFu <[email protected]>
  • Loading branch information
ydFu committed Feb 19, 2021
1 parent fd8ee1d commit 1cb1ac4
Show file tree
Hide file tree
Showing 2 changed files with 28 additions and 11 deletions.
36 changes: 27 additions & 9 deletions content/zh/docs/concepts/services-networking/dual-stack.md
Original file line number Diff line number Diff line change
Expand Up @@ -9,11 +9,17 @@ weight: 70
---

<!--
reviewers:
- lachie83
- khenidak
- aramase
- bridgetkromhout
title: IPv4/IPv6 dual-stack
feature:
title: IPv4/IPv6 dual-stack
description: >
Allocation of IPv4 and IPv6 addresses to Pods and Services
content_type: concept
weight: 70
-->
Expand Down Expand Up @@ -85,6 +91,20 @@ The following prerequisites are needed in order to utilize IPv4/IPv6 dual-stack

<!--
To enable IPv4/IPv6 dual-stack, enable the `IPv6DualStack` [feature gate](/docs/reference/command-line-tools-reference/feature-gates/) for the relevant components of your cluster, and set dual-stack cluster network assignments:
* kube-apiserver:
* `--feature-gates="IPv6DualStack=true"`
* `--service-cluster-ip-range=<IPv4 CIDR>,<IPv6 CIDR>`
* kube-controller-manager:
* `--feature-gates="IPv6DualStack=true"`
* `--cluster-cidr=<IPv4 CIDR>,<IPv6 CIDR>`
* `--service-cluster-ip-range=<IPv4 CIDR>,<IPv6 CIDR>`
* `--node-cidr-mask-size-ipv4|--node-cidr-mask-size-ipv6` defaults to /24 for IPv4 and /64 for IPv6
* kubelet:
* `--feature-gates="IPv6DualStack=true"`
* kube-proxy:
* `--cluster-cidr=<IPv4 CIDR>,<IPv6 CIDR>`
* `--feature-gates="IPv6DualStack=true"`
-->
要启用 IPv4/IPv6 双协议栈,为集群的相关组件启用 `IPv6DualStack`
[特性门控](/zh/docs/reference/command-line-tools-reference/feature-gates/)
Expand All @@ -95,8 +115,8 @@ To enable IPv4/IPv6 dual-stack, enable the `IPv6DualStack` [feature gate](/docs/
* `--service-cluster-ip-range=<IPv4 CIDR>,<IPv6 CIDR>`
* kube-controller-manager:
* `--feature-gates="IPv6DualStack=true"`
* `--cluster-cidr=<IPv4 CIDR>,<IPv6 CIDR>` 例如 `--cluster-cidr=10.244.0.0/16,fc00::/48`
* `--service-cluster-ip-range=<IPv4 CIDR>,<IPv6 CIDR>` 例如 `--service-cluster-ip-range=10.0.0.0/16,fd00::/108`
* `--cluster-cidr=<IPv4 CIDR>,<IPv6 CIDR>`
* `--service-cluster-ip-range=<IPv4 CIDR>,<IPv6 CIDR>`
* `--node-cidr-mask-size-ipv4|--node-cidr-mask-size-ipv6` 对于 IPv4 默认为 /24,对于 IPv6 默认为 /64
* kubelet:
* `--feature-gates="IPv6DualStack=true"`
Expand Down Expand Up @@ -132,7 +152,7 @@ set the `.spec.ipFamilyPolicy` field to one of the following values:
-->
如果你的集群启用了 IPv4/IPv6 双协议栈网络,则可以使用 IPv4 或 IPv6 地址来创建
{{< glossary_tooltip text="Service" term_id="service" >}}。
服务的地址族默认为第一个服务集群 IP 范围的地址族(通过 kube-apiserver 的 `--service-cluster-ip-range` 参数配置)
服务的地址族默认为第一个服务集群 IP 范围的地址族(通过 kube-apiserver 的 `--service-cluster-ip-range` 参数配置)
当你定义服务时,可以选择将其配置为双栈。若要指定所需的行为,你可以设置 `.spec.ipFamilyPolicy` 字段为以下值之一:

<!--
Expand Down Expand Up @@ -396,9 +416,9 @@ For [Headless Services without selectors](/docs/concepts/services-networking/ser
若没有显式设置 `.spec.ipFamilyPolicy`,则 `.spec.ipFamilyPolicy` 字段默认设置为 `RequireDualStack`。

<!--
### Type LoadBalancer
### Service type LoadBalancer
-->
### LoadBalancer 类型
### LoadBalancer 类型服务

<!--
To provision a dual-stack load balancer for your Service:
Expand All @@ -418,7 +438,7 @@ To use a dual-stack `LoadBalancer` type Service, your cloud provider must suppor
{{< /note >}}

<!--
## Egress Traffic
## Egress traffic
-->
## 出站流量

Expand All @@ -440,6 +460,4 @@ Ensure your {{< glossary_tooltip text="CNI" term_id="cni" >}} provider supports
<!--
* [Validate IPv4/IPv6 dual-stack](/docs/tasks/network/validate-dual-stack) networking
-->
* [验证 IPv4/IPv6 双协议栈](/zh/docs/tasks/network/validate-dual-stack)网络


* [验证 IPv4/IPv6 双协议栈](/zh/docs/tasks/network/validate-dual-stack)网络
Original file line number Diff line number Diff line change
Expand Up @@ -125,7 +125,7 @@ Once it returns (without giving an error), you can power down the node
If you leave the node in the cluster during the maintenance operation, you need to run
-->
一旦它返回(没有报错),
你就可以下电此节点(或者等价地,如果在云平台上,删除支持该节点的虚拟机)。
你就可以下线此节点(或者等价地,如果在云平台上,删除支持该节点的虚拟机)。
如果要在维护操作期间将节点留在集群中,则需要运行:

```shell
Expand Down Expand Up @@ -295,4 +295,3 @@ Kubernetes 并没有具体说明在这种情况下应该采取什么行为,
-->
* 执行[配置 PDB](/zh/docs/tasks/run-application/configure-pdb/)中的各个步骤,
保护你的应用

0 comments on commit 1cb1ac4

Please sign in to comment.