read/readwrite: Add option not to check data size #113

Merged
merged 2 commits into from Apr 27, 2020
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
62 changes: 52 additions & 10 deletions pyads/ads.py
Original file line number Diff line number Diff line change
Expand Up @@ -248,8 +248,9 @@ def read_write(
value,
plc_write_datatype,
return_ctypes=False,
check_length=True,
):
# type: (AmsAddr, int, int, Type, Any, Type, bool) -> Any
# type: (AmsAddr, int, int, Type, Any, Type, bool, bool) -> Any
"""Read and write data synchronous from/to an ADS-device.

:param AmsAddr adr: local or remote AmsAddr
Expand All @@ -263,6 +264,8 @@ def read_write(
PLCTYPE constants
:param bool return_ctypes: return ctypes instead of python types if True
(default: False)
:param bool check_length: check whether the amount of bytes read matches the size
of the read data type (default: True)
:rtype: PLCTYPE
:return: value: **value**

Expand All @@ -277,13 +280,16 @@ def read_write(
value,
plc_write_datatype,
return_ctypes,
check_length,
)

return None


def read(adr, index_group, index_offset, plc_datatype, return_ctypes=False):
# type: (AmsAddr, int, int, Type, bool) -> Any
def read(
adr, index_group, index_offset, plc_datatype, return_ctypes=False, check_length=True
):
# type: (AmsAddr, int, int, Type, bool, bool) -> Any
"""Read data synchronous from an ADS-device.

:param AmsAddr adr: local or remote AmsAddr
Expand All @@ -294,18 +300,26 @@ def read(adr, index_group, index_offset, plc_datatype, return_ctypes=False):
PLCTYPE constants
:param bool return_ctypes: return ctypes instead of python types if True
(default: False)
:param bool check_length: check whether the amount of bytes read matches the size
of the read data type (default: True)
:return: value: **value**

"""
if port is not None:
return adsSyncReadReqEx2(
port, adr, index_group, index_offset, plc_datatype, return_ctypes
port,
adr,
index_group,
index_offset,
plc_datatype,
return_ctypes,
check_length,
)

return None


def read_by_name(adr, data_name, plc_datatype, return_ctypes=False):
def read_by_name(adr, data_name, plc_datatype, return_ctypes=False, check_length=True):
# type: (AmsAddr, str, Type, bool) -> Any
"""Read data synchronous from an ADS-device from data name.

Expand All @@ -315,11 +329,15 @@ def read_by_name(adr, data_name, plc_datatype, return_ctypes=False):
PLCTYPE constants
:param bool return_ctypes: return ctypes instead of python types if True
(default: False)
:param bool check_length: check whether the amount of bytes read matches the size
of the read data type (default: True)
:return: value: **value**

"""
if port is not None:
return adsSyncReadByNameEx(port, adr, data_name, plc_datatype, return_ctypes)
return adsSyncReadByNameEx(
port, adr, data_name, plc_datatype, return_ctypes, check_length=check_length
)

return None

Expand Down Expand Up @@ -724,8 +742,9 @@ def read_write(
value,
plc_write_datatype,
return_ctypes=False,
check_length=True,
):
# type: (int, int, Type, Any, Type, bool) -> Any
# type: (int, int, Type, Any, Type, bool, bool) -> Any
"""Read and write data synchronous from/to an ADS-device.

:param int index_group: PLC storage area, according to the INDEXGROUP
Expand All @@ -739,6 +758,8 @@ def read_write(
:rtype: PLCTYPE
:param bool return_ctypes: return ctypes instead of python types if True
(default: False)
:param bool check_length: check whether the amount of bytes read matches the size
of the read data type (default: True)
:return: value: **value**

"""
Expand All @@ -752,12 +773,20 @@ def read_write(
value,
plc_write_datatype,
return_ctypes,
check_length,
)

return None

def read(self, index_group, index_offset, plc_datatype, return_ctypes=False):
# type: (int, int, Type, bool) -> Any
def read(
self,
index_group,
index_offset,
plc_datatype,
return_ctypes=False,
check_length=True,
):
# type: (int, int, Type, bool, bool) -> Any
"""Read data synchronous from an ADS-device.

:param int index_group: PLC storage area, according to the INDEXGROUP
Expand All @@ -768,6 +797,8 @@ def read(self, index_group, index_offset, plc_datatype, return_ctypes=False):
:return: value: **value**
:param bool return_ctypes: return ctypes instead of python types if True
(default: False)
:param bool check_length: check whether the amount of bytes read matches the size
of the read data type (default: True)

"""
if self._port is not None:
Expand All @@ -778,6 +809,7 @@ def read(self, index_group, index_offset, plc_datatype, return_ctypes=False):
index_offset,
plc_datatype,
return_ctypes,
check_length,
)

return None
Expand Down Expand Up @@ -806,7 +838,14 @@ def release_handle(self, handle):
if self._port is not None:
adsReleaseHandle(self._port, self._adr, handle)

def read_by_name(self, data_name, plc_datatype, return_ctypes=False, handle=None):
def read_by_name(
self,
data_name,
plc_datatype,
return_ctypes=False,
handle=None,
check_length=True,
):
# type: (str, Type, bool, int) -> Any
"""Read data synchronous from an ADS-device from data name.

Expand All @@ -818,6 +857,8 @@ def read_by_name(self, data_name, plc_datatype, return_ctypes=False, handle=None
(default: False)
:param int handle: PLC-variable handle, pass in handle if previously
obtained to speed up reading (default: None)
:param bool check_length: check whether the amount of bytes read matches the size
of the read data type (default: True)

"""
if self._port:
Expand All @@ -828,6 +869,7 @@ def read_by_name(self, data_name, plc_datatype, return_ctypes=False, handle=None
plc_datatype,
return_ctypes=return_ctypes,
handle=handle,
check_length=check_length,
)

return None
Expand Down
49 changes: 41 additions & 8 deletions pyads/pyads_ex.py
Original file line number Diff line number Diff line change
Expand Up @@ -502,8 +502,9 @@ def adsSyncReadWriteReqEx2(
value,
write_data_type,
return_ctypes=False,
check_length=True,
):
# type: (int, AmsAddr, int, int, Type, Any, Type, bool) -> Any
# type: (int, AmsAddr, int, int, Type, Any, Type, bool, bool) -> Any
"""Read and write data synchronous from/to an ADS-device.

:param int port: local AMS port as returned by adsPortOpenEx()
Expand All @@ -518,6 +519,8 @@ def adsSyncReadWriteReqEx2(
PLCTYPE constants
:param bool return_ctypes: return ctypes instead of python types if True
(default: False)
:param bool check_length: check whether the amount of bytes read matches the size
of the read data type (default: True)
:rtype: read_data_type
:return: value: value read from PLC

Expand Down Expand Up @@ -571,7 +574,11 @@ def adsSyncReadWriteReqEx2(

# If we're reading a value of predetermined size (anything but a string),
# validate that the correct number of bytes were read
if read_data_type != PLCTYPE_STRING and bytes_read.value != read_length.value:
if (
check_length
and read_data_type != PLCTYPE_STRING
and bytes_read.value != read_length.value
):
raise RuntimeError(
"Insufficient data (expected {0} bytes, {1} were read).".format(
read_length.value, bytes_read.value
Expand All @@ -594,9 +601,15 @@ def adsSyncReadWriteReqEx2(


def adsSyncReadReqEx2(
port, address, index_group, index_offset, data_type, return_ctypes=False
port,
address,
index_group,
index_offset,
data_type,
return_ctypes=False,
check_length=True,
):
# type: (int, AmsAddr, int, int, Type, bool) -> Any
# type: (int, AmsAddr, int, int, Type, bool, bool) -> Any
"""Read data synchronous from an ADS-device.

:param int port: local AMS port as returned by adsPortOpenEx()
Expand All @@ -608,6 +621,8 @@ def adsSyncReadReqEx2(
PLCTYPE constants
:param bool return_ctypes: return ctypes instead of python types if True
(default: False)
:param bool check_length: check whether the amount of bytes read matches the size
of the read data type (default: True)
:rtype: data_type
:return: value: **value**

Expand Down Expand Up @@ -644,7 +659,11 @@ def adsSyncReadReqEx2(

# If we're reading a value of predetermined size (anything but a string),
# validate that the correct number of bytes were read
if data_type != PLCTYPE_STRING and bytes_read.value != data_length.value:
if (
check_length
and data_type != PLCTYPE_STRING
and bytes_read.value != data_length.value
):
raise RuntimeError(
"Insufficient data (expected {0} bytes, {1} were read).".format(
data_length.value, bytes_read.value
Expand Down Expand Up @@ -701,9 +720,15 @@ def adsReleaseHandle(port, address, handle):


def adsSyncReadByNameEx(
port, address, data_name, data_type, return_ctypes=False, handle=None
port,
address,
data_name,
data_type,
return_ctypes=False,
handle=None,
check_length=True,
):
# type: (int, AmsAddr, str, Type, bool, int) -> Any
# type: (int, AmsAddr, str, Type, bool, int, bool) -> Any
"""Read data synchronous from an ADS-device from data name.

:param int port: local AMS port as returned by adsPortOpenEx()
Expand All @@ -714,6 +739,8 @@ def adsSyncReadByNameEx(
:param bool return_ctypes: return ctypes instead of python types if True
(default: False)
:param int handle: PLC-variable handle (default: None)
:param bool check_length: check whether the amount of bytes read matches the size
of the read data type (default: True)
:rtype: data_type
:return: value: **value**

Expand All @@ -726,7 +753,13 @@ def adsSyncReadByNameEx(

# Read the value of a PLC-variable, via handle
value = adsSyncReadReqEx2(
port, address, ADSIGRP_SYM_VALBYHND, handle, data_type, return_ctypes
port,
address,
ADSIGRP_SYM_VALBYHND,
handle,
data_type,
return_ctypes,
check_length,
)

if no_handle is True:
Expand Down
4 changes: 4 additions & 0 deletions pyads/testserver.py
Original file line number Diff line number Diff line change
Expand Up @@ -485,6 +485,10 @@ class AdvancedHandler(AbstractHandler):
"""

def __init__(self):
# type: () -> None
self.reset()

def reset(self):
# type: () -> None
self._data = defaultdict(
lambda: bytes(16)
Expand Down
71 changes: 70 additions & 1 deletion tests/test_integration.py
Original file line number Diff line number Diff line change
Expand Up @@ -14,7 +14,7 @@
from pyads import ads, constants
from pyads.utils import platform_is_linux
from pyads.structs import AmsAddr, NotificationAttrib
from pyads.testserver import AdsTestServer
from pyads.testserver import AdsTestServer, AdvancedHandler


# These are pretty arbitrary
Expand Down Expand Up @@ -468,5 +468,74 @@ def callback(handle, name, timestamp, value):
plc.write_by_name("a", 1, pyads.PLCTYPE_INT)


class AdsApiTestCaseAdvanced(TestCase):
@classmethod
def setUpClass(cls):
# Start dummy ADS Endpoint
cls.test_server = AdsTestServer(AdvancedHandler(), logging=False)
cls.test_server.start()

# Endpoint AMS Address
cls.endpoint = AmsAddr(TEST_SERVER_AMS_NET_ID, TEST_SERVER_AMS_PORT)

# Open AMS Port
ads.open_port()

# wait a bit otherwise error might occur
time.sleep(1)

# NOTE: On a Windows machine, this route needs to be configured
# within the router service for the tests to work.
if platform_is_linux():
ads.add_route(cls.endpoint, TEST_SERVER_IP_ADDRESS)

@classmethod
def tearDownClass(cls):
cls.test_server.stop()

# wait a bit for server to shutdown
time.sleep(1)

ads.close_port()

if platform_is_linux():
ads.delete_route(cls.endpoint)

def setUp(self):
# Clear request history before each test
self.test_server.request_history = []
self.test_server.handler.reset()

def test_read_check_length(self):
# Write data shorter than what should be read
ads.write(
self.endpoint,
value=1,
index_group=constants.INDEXGROUP_DATA,
index_offset=1,
plc_datatype=constants.PLCTYPE_USINT,
)

with self.assertRaises(RuntimeError):
# Since the length is checked, this must give an error
ads.read(
self.endpoint,
index_group=constants.INDEXGROUP_DATA,
index_offset=1,
plc_datatype=constants.PLCTYPE_UINT,
check_length=True,
)

# If the length is not checked, no error should be raised
value = ads.read(
self.endpoint,
index_group=constants.INDEXGROUP_DATA,
index_offset=1,
plc_datatype=constants.PLCTYPE_UINT,
check_length=False,
)
self.assertEqual(value, 1)