Skip to content

Commit

Permalink
Allow modifying Illuminance, Humidity, and Occupancy sensors from the…
Browse files Browse the repository at this point in the history
… M5Stack (#15940)

* Allow modifying Illuminance, Humidity, and Occupancy sensors from the M5Stack

* Fix incorrect log message.

* Make occupancy a boolean

* Fix printing of value
  • Loading branch information
sagar-apple authored and pull[bot] committed Aug 30, 2023
1 parent 405c9e8 commit 2346532
Showing 1 changed file with 27 additions and 6 deletions.
33 changes: 27 additions & 6 deletions examples/all-clusters-app/esp32/main/DeviceWithDisplay.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -112,7 +112,7 @@ class EditAttributeListModel : public TouchesMatterStackModel
{
auto & attribute = this->attribute();
auto & value = std::get<1>(attribute);
return value == "On" || value == "Off";
return value == "On" || value == "Off" || value == "Yes" || value == "No";
}
virtual std::string GetTitle()
{
Expand Down Expand Up @@ -169,20 +169,41 @@ class EditAttributeListModel : public TouchesMatterStackModel
ESP_LOGI(TAG, "Saturation changed to : %d", n * 100 / 254);
app::Clusters::ColorControl::Attributes::CurrentSaturation::Set(1, n);
}
else if (name == "Illuminance")
{
// update the current illuminance here for hardcoded endpoint 1
ESP_LOGI(TAG, "Illuminance changed to : %d", n);
app::Clusters::IlluminanceMeasurement::Attributes::MeasuredValue::Set(1, static_cast<int16_t>(n));
}
else if (name == "Humidity")
{
// update the current humidity here for hardcoded endpoint 1
ESP_LOGI(TAG, "Humidity changed to : %d", n);
app::Clusters::RelativeHumidityMeasurement::Attributes::MeasuredValue::Set(1, static_cast<int16_t>(n * 100));
}
value = buffer;
}
else if (IsBooleanAttribute())
{
auto & name = std::get<0>(attribute);
auto & cluster = std::get<0>(std::get<1>(std::get<1>(devices[deviceIndex])[endpointIndex])[i]);
value = (value == "On") ? "Off" : "On";

if (name == "OnOff" && cluster == "OnOff")
{
value = (value == "On") ? "Off" : "On";
uint8_t attributeValue = (value == "On") ? 1 : 0;
emberAfWriteServerAttribute(endpointIndex + 1, ZCL_ON_OFF_CLUSTER_ID, ZCL_ON_OFF_ATTRIBUTE_ID,
(uint8_t *) &attributeValue, ZCL_BOOLEAN_ATTRIBUTE_TYPE);
}

if (name == "Occupancy" && cluster == "Occupancy Sensor")
{
value = (value == "Yes") ? "No" : "Yes";
uint8_t attributeValue = (value == "Yes") ? 1 : 0;
ESP_LOGI(TAG, "Occupancy changed to : %s", value.c_str());
// update the current occupancy here for hardcoded endpoint 1
app::Clusters::OccupancySensing::Attributes::Occupancy::Set(1, attributeValue);
}
}
else
{
Expand Down Expand Up @@ -437,13 +458,13 @@ void SetupPretendDevices()
AddDevice("Occupancy Sensor");
AddEndpoint("External");
AddCluster("Occupancy Sensor");
AddAttribute("Occupancy", "1");
AddAttribute("Occupancy", "Yes");
app::Clusters::OccupancySensing::Attributes::Occupancy::Set(1, 1);

AddDevice("Contact Sensor");
AddEndpoint("External");
AddCluster("Contact Sensor");
AddAttribute("BooleanState", "true");
AddAttribute("Contact", "true");
app::Clusters::BooleanState::Attributes::StateValue::Set(1, true);

AddDevice("Thermostat");
Expand All @@ -461,13 +482,13 @@ void SetupPretendDevices()
AddDevice("Humidity Sensor");
AddEndpoint("External");
AddCluster("Humidity Sensor");
AddAttribute("MeasuredValue", "30");
AddAttribute("Humidity", "30");
app::Clusters::RelativeHumidityMeasurement::Attributes::MeasuredValue::Set(1, static_cast<int16_t>(30 * 100));

AddDevice("Light Sensor");
AddEndpoint("External");
AddCluster("Illuminance Measurement");
AddAttribute("MeasuredValue", "1000");
AddAttribute("Illuminance", "1000");
app::Clusters::IlluminanceMeasurement::Attributes::MeasuredValue::Set(1, static_cast<int16_t>(1000));

AddDevice("Color Light");
Expand Down

0 comments on commit 2346532