12 changes: 10 additions & 2 deletions bundles/org.openhab.binding.modbus/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -16,6 +16,14 @@ The binding has the following extensions:

<!--list-subs-->

The rest of this page contains details for configuring this binding:

{::options toc_levels="2..4"/}

- TOC
{:toc}



## Main Features

Expand Down Expand Up @@ -168,7 +176,7 @@ You must give each of your bridge Things a reference (thing ID) that is unique f
| Parameter | Type | Required | Default if omitted | Description |
| ------------- | ------- | -------- | ------------------ | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| `start` | integer | | `0` | Address of the first register, coil, or discrete input to poll. Input as zero-based index number. |
| `length` | integer | ✓ | (-) | Number of registers, coils or discrete inputs to read. |
| `length` | integer | ✓ | (-) | Number of registers, coils or discrete inputs to read. Note that protocol limits max length, depending on type |
| `type` | text | ✓ | (-) | Type of modbus items to poll. This matches directly to Modbus request type or function code (FC). Valid values are: `"coil"` (FC01), `"discrete"` (FC02), `"holding"`(FC03), `"input"` (FC04). |
| `refresh` | integer | | `500` | Poll interval in milliseconds. Use zero to disable automatic polling. |
| `maxTries` | integer | | `3` | Maximum tries when reading. <br /><br />Number of tries when reading data, if some of the reading fail. For single try, enter 1. |
Expand Down Expand Up @@ -302,7 +310,7 @@ Main documentation on `autoupdate` in [Items section of openHAB docs](https://ww

Device specific modbus bindings can take part in the discovery of things, and detect devices automatically. The discovery is initiated by the `tcp` and `serial` bridges when they have `enableDiscovery` setting enabled.

Note that the main binding does not recognize any device, so it is pointless to turn this on unless you have the correct binding installed.
Note that the main binding does not recognize any devices, so it is pointless to turn this on unless you have a suitable add-on binding installed.