hey @catap we're technically calling promtail feature complete but I think we can make a case for this really being a fix rather than being a feature if promtail didn't work with BSD syslog before, though we would definitely want to wait for your changes to be upstreamed via influxdata/go-syslog#55 first |
Hey @cstyan! Yes, BSD syslog were nuke when support of syslog was introduced at #1275 since when was one attempt #7845 to do it which I've reused. As part of that attempt the PR: influxdata/go-syslog#46 with required changes inside go-syslog were created but nobody had reviewed it. It was December 2022. I doubt that my PR will be merged some time soon, let be honest. But this changes which is localized inside not used before code allows me to introduce support of different devices which sends logs to Loki. From BSD system to Nginx with Unifi Networks and so on. So, what's a plan here? I see that https://github.com/grafana/go-syslog exists and I may open PR into this repository, but as far as I see nobody uses it. |
Just a rebase to the last main. |
Unfortunately I don't have any suggestions here at the moment. Given we're winding down our own work on promtail and (to my knowledge) don't use the syslog target ourselves I don't really want to take on maintenance of this code within the Loki repo. It's likely better to ask the Alloy team to take on maintenance of the code either directly or via a fork, though I doubt that will happen anytime soon either. They have their own open issue tracking support for the same RFC: grafana/alloy#305 My only other suggestion would be opening an issue on the go-syslog repo itself asking if the repo is unmaintained and trying to get in contact with someone from Influx who has worked on it in the past. It's likely it would also get no response, or a response of "yes, unmaintained". In either case, hopefully that would entice someone else in the Go community to take on maintenance of a fork. |
From another hand: do you see any objection to merge? If this code will be removed soon enough, when you decided to nuke promtail, why not keep it with this feature? It doesn't change any existed code, just add a new one feature which should be enabled by hand. Upstream project looks like to be forgetten to be archived, but this code increases use case of loki right now, that should attract new users for Loki. |
Yes, because we're not just getting rid of promtail. It's going to be maintained with security and bug fixes for (I'm just trying to make a reasonable guess here) a year or two if not more. What we are not doing is supporting additional features. We could make an argument for this being a fix but the actual changes you're making to |
I see your point and I haven't got any resources to promise you to support Frankly speaking after xz-history I understand why you decided to go this way. But, as I said before, I really think that this PR will benefite Lokie and Grafana ecosystem. Maybe as better approach you may tag someone from Alloy team? I had quite a fast look to their code and it seems like a fork of promtail. |
I don't disagree.
We can ping them like this @grafana/grafana-alloy-maintainers, but we also had a discussion internally, the consensus was that we don't have the bandwidth to maintain go-syslog ourselves and finding another solution is low priority at the moment.
It's a hard fork of some of promtails code, yes. |
Seems that github included comma into name of group and decided to not ping them. So, here I'm to ping: @grafana/grafana-alloy-maintainers |
This adds support for RFC3164 syslogs which are used by many devices, in my use case OpenWrt and Ubiquiti routers. A new option called `is_rfc3164_message` is added to the syslog which makes the incomming logs to be handled as RFC3164. Co-Authored-By: Paul Spooren <[email protected]> Signed-off-by: Kirill A. Korinsky <[email protected]>
@cstyan here an update. @leodido had forked his After that he had merged the PR, and here I'm back with reduced PR which:
|
That's great news 👍 |
Yup, I decided to keep maintaining it at https://github.com/leodido/go-syslog |
// IsRFC3164Message defines wether the log is formated as RFC3164 | ||
IsRFC3164Message bool `yaml:"is_rfc3164_message"` | ||
|
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Sorry @catap I thought I left this comment yesterday:
Is there a way we can just detect whether each message is RFC3164 or RFC5424 format, rather than adding another config option? Is it possible that a single target could output logs in both formats?
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
@cstyan nope, it is impossible to determine which format is used. Usually sender sends in supported format, or it may have a selector where someone may choose the format.
The best that I can do here is use handleMessageRFC3164
as fallback. If RFC5424
can't parse it, let use RFC3164
but it may lead to the case when RFC5424
parses it wrong way, so, I suggest to avoid that.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Okay that's fine.
Lets keep the logic as is then, except can we change the config option to be SyslogFormat
which has multiple string possibilities, like one of RFC5425, RFC3164, another RFC, etc.
? And then have a validation function when creating the loading the syslog config or creating the syslog target.
And it's default value can be RFC5424
. That way we don't need to add another config field if at some point the future we add support for yet another format. it just has to be another possible option for the validation function.
We also need a reference for this in the syslog section of docs/sources/send-data/promtail/configuration.md
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Here the catch: right now we have two options:
// UseRFC5424Message defines whether the full RFC5424 formatted syslog
// message should be pushed to Loki
UseRFC5424Message bool `yaml:"use_rfc5424_message"`
// IsRFC3164Message defines wether the log is formated as RFC3164
IsRFC3164Message bool `yaml:"is_rfc3164_message"`
and I feel that this should be reworked as weel. To something like:
- SyslogFormat: RFC5424 (default) or RFC3164;
- UseFullSyslogMessage: default is false
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
and I feel that this should be reworked as weel. To something like:
SyslogFormat: RFC5424 (default) or RFC3164;
UseFullSyslogMessage: default is false
this makes sense to me, we would have to deprecate UseRFC5424Message
for now and have the actual value for use syslog
be an or of UseRFC5424
and UseFullSyslogFormat: false
when SyslogFormat
is RFC5424
I can present your PR to the team as a "we should do this as a bug fix, it also technically requires these config changes" and we should be able to get it merged
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
@cstyan I was wrong, RFC3164 hasn't got string method and implement it isn't something that seems easy. So, let keep it as is.
@cstyan to make review easy, I've added all remarks as dedicated commit. Feel free to ask, if I need to squash it. |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
No need to squash/force push. It's actually easier to review if you push new commits for new changes. We always squash when merging back into main anyways.
@@ -202,15 +211,19 @@ type SyslogTargetConfig struct { | |||
// message should be pushed to Loki | |||
UseRFC5424Message bool `yaml:"use_rfc5424_message"` |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I think we wanted a second new config option PushFullSyslogMessage
? we still need to keep this one as well, and mark it as deprecated
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I can't do it, because RFC3164 message has lack of String()
method. See implementation for RFC5424: https://github.com/leodido/go-syslog/blob/v4.1.0/rfc5424/builder.go#L9348-L9408
The issue that RFC3164 isn't well structured and quite flexible, and rebuild original message is quite a challenge.
Sorry to misslead you.
@@ -225,7 +225,7 @@ func (t *SyslogTarget) handleMessageRFC3164(connLabels labels.Labels, msg syslog | |||
} | |||
|
|||
func (t *SyslogTarget) handleMessage(connLabels labels.Labels, msg syslog.Message) { | |||
if t.config.IsRFC3164Message { | |||
if t.config.IsRFC3164Message() { |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I think switching on the config.SyslogFormat
would be cleaner
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Here possible, but it is using in few more places, and it leads to ==
and need to export the contant name, or hardcoded strings...
So, I've decided to use trivial method which can be refactored.
Anyway, here only two RFC for Syslog, and I doubt that someone will make 3rd soon enough.
Co-authored-by: Callum Styan <[email protected]>
okay, I think we're probably good to go I'll take another look in the morning |
@cstyan may I ask you to re-run tests, this time with |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
just one last change needed imo
@@ -202,12 +211,19 @@ type SyslogTargetConfig struct { | |||
// message should be pushed to Loki | |||
UseRFC5424Message bool `yaml:"use_rfc5424_message"` | |||
|
|||
// Syslog format used at the target. |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I think we should clarify the valid options here, and that rfc5424
is the default.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
we could implement the default in the parser or like this:
loki/clients/pkg/promtail/targets/syslog/syslogtarget.go
Lines 233 to 238 in efdae3d
func (t *SyslogTarget) transportProtocol() string { | |
if t.config.ListenProtocol != "" { | |
return t.config.ListenProtocol | |
} | |
return defaultProtocol | |
} |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
It looks like we don't have a dedicated config parsing function on this path, so maybe in NewSyslogTarget
would make the most sense to detect if SyslogFormat
is empty string and if so set the default
@cstyan ping |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Thanks for your patience @catap! Sorry for the delay, I was on vacation last week.
What this PR does / why we need it:
This PR introduce support of RFC3164 at promtail with additional hacks to support old and wired implementations.
It includes different BSD system such as OpenBSD and some embeded system. Frankly speaking all of them that I have access: from OpenBSD server to Unifi UA and IP Socket and Synology NAS with Nginx, works with this changes.
Both protocol TCP and UDP works.
It based on #7845 and requries some changes inside used go-syslog library which was accomulated as single PR influxdata/go-syslog#55 but upstream of that library seems to be not so active.
It is tested with config like:
Which issue(s) this PR fixes:
A few times was made quite clear that such things aren't supported. So, no issue were opened.
Checklist
CONTRIBUTING.md
guide (required)