You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Above, Facet L-Band, d3.9, has no SD inserted. Periodic battery and location accuracy reports turned off. About once a minute, a erroneous message is reported. This is due to the low level SD test returning a false positive. When SD is then started, the sdPresent test correctly fails and the system continues. It's
This issue is rarely seen. It could not be replicated on other devices (RTK Express Plus, RTK Facet, etc).
Above, the SD test takes about 64ms to run 5 sdPresent() tests, 13ms per test.
Solution: The report should only be printed if an SD card was started.
The text was updated successfully, but these errors were encountered:
Above, Facet L-Band, d3.9, has no SD inserted. Periodic battery and location accuracy reports turned off. About once a minute, a erroneous message is reported. This is due to the low level SD test returning a false positive. When SD is then started, the sdPresent test correctly fails and the system continues. It's
This issue is rarely seen. It could not be replicated on other devices (RTK Express Plus, RTK Facet, etc).
Above, the SD test takes about 64ms to run 5 sdPresent() tests, 13ms per test.
Solution: The report should only be printed if an SD card was started.
The text was updated successfully, but these errors were encountered: