[watermarkstat] Fix CLI script for unconfigured PG counters #2239
Merged
Conversation
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
commit 409da5f Author: Shlomi Bitton <[email protected]> Date: Tue Jun 14 16:17:20 2022 +0000 Fix watermarkstat CLI script. Since PG/Queue counters are created only if they are configured in the switch, it is not enough to relay only on the first entry in the DB. We need to go over all configured counters, check what is the max configured, and build the table accordingly. Signed-off-by: Shlomi Bitton <[email protected]> Signed-off-by: Nazarii Hnydyn <[email protected]>
nazariig
changed the title
[watermarkstat] Fix CLI script
[watermarkstat] Fix CLI script for unconfigured PG counters
Jun 28, 2022
@neethajohn can you please review? |
@neethajohn could you please help to review and signoff? |
@neethajohn can you review this change? |
developfast
reviewed
Jul 28, 2022
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
lgtm! @neethajohn
neethajohn
approved these changes
Jul 28, 2022
7 tasks
yxieca
pushed a commit
that referenced
this pull request
Aug 8, 2022
Signed-off-by: Nazarii Hnydyn [email protected] Propagating #2220 with resolved review comments What I did Since PG counters are created only if they are configured in the switch, it is not enough to relay only on the first entry in the DB when building the output table of watermarkstat script. We need to go over all configured counters, check what is the max configured, and build the table accordingly. How I did it Iterate all configured PG buffers for all ports and find the max index. Build the output table according to the max index. How to verify it Run test "iface_namingmode/test_iface_namingmode.py" including this PR: sonic-net/sonic-swss#2143 and observe it passes.
dprital
added a commit
to dprital/sonic-buildimage
that referenced
this pull request
Aug 9, 2022
Update sonic-utilities submodule pointer to include the following: * Fix GCU bug when backend service modifying config ([sonic-net#2295](sonic-net/sonic-utilities#2295)) * Fix issues for sonic_installer upgrade-docker and sonic_installer rollback-docker ([sonic-net#2278](sonic-net/sonic-utilities#2278)) * [crm] add checking for CRM interval range ([sonic-net#2293](sonic-net/sonic-utilities#2293)) * Fix the issue that sonic_platform is not installed on vs image ([sonic-net#2300](sonic-net/sonic-utilities#2300)) * Add FEC correctable and uncorrectable port stats ([sonic-net#2027](sonic-net/sonic-utilities#2027)) * Add CLI to configure YANG config validation ([sonic-net#2147](sonic-net/sonic-utilities#2147)) * Add override testcase to verify removal ([sonic-net#2288](sonic-net/sonic-utilities#2288)) * Fix version in db_migrator for ([sonic-net#2289](sonic-net/sonic-utilities#2289)) * [intfutil] Check whether the FEC mode is supported on the platform before configuring it to CONFIG_DB ([sonic-net#2223](sonic-net/sonic-utilities#2223)) * Transfer organization from Azure to sonic-net ([sonic-net#2284](sonic-net/sonic-utilities#2284)) * [watermarkstat] Fix CLI script for unconfigured PG counters ([sonic-net#2239](sonic-net/sonic-utilities#2239)) * Improve the way to check port type of RJ45 port ([sonic-net#2249](sonic-net/sonic-utilities#2249)) Signed-off-by: dprital <[email protected]>
7 tasks
liat-grozovik
pushed a commit
to sonic-net/sonic-swss
that referenced
this pull request
Aug 25, 2022
…r queue/pg counters (#2360) Propagating #2143 with resolved merge conflicts Depends on: sonic-net/sonic-utilities#2239 - What I did Currently in SONiC all ports queue and pg counters are created by default with the max possible amount of counters. This feature change this behavior to poll only configured counters provided by the config DB BUFFER_PG and BUFFER_QUEUE tables. If no tables are present in the DB, no counters will be created for ports. Filter the unwanted queues/pgs returned by SAI API calls and skip the creation of these queue/pg counters. Also allow creating/removing counters on runtime if buffer PG/Queue is configured or removed. - Why I did it Improve performance by filtering unconfigured queue/pg counters on init. - How I verified it Check after enabling the counters, if configured counters created in Counters DB according to the configurations. Add/Remove buffer PG/Queue configurations and observe the corresponding counters created/removed accordingly. New UT added to verify this flow. Signed-off-by: Nazarii Hnydyn <[email protected]>
preetham-singh
pushed a commit
to preetham-singh/sonic-utilities
that referenced
this pull request
Nov 21, 2022
…t#2239) Signed-off-by: Nazarii Hnydyn [email protected] Propagating sonic-net#2220 with resolved review comments What I did Since PG counters are created only if they are configured in the switch, it is not enough to relay only on the first entry in the DB when building the output table of watermarkstat script. We need to go over all configured counters, check what is the max configured, and build the table accordingly. How I did it Iterate all configured PG buffers for all ports and find the max index. Build the output table according to the max index. How to verify it Run test "iface_namingmode/test_iface_namingmode.py" including this PR: sonic-net/sonic-swss#2143 and observe it passes.
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Signed-off-by: Nazarii Hnydyn [email protected]
Propagating #2220 with resolved review comments
What I did
Since PG counters are created only if they are configured in the switch, it is not enough to relay only on the first entry in the DB when building the output table of watermarkstat script.
We need to go over all configured counters, check what is the max configured, and build the table accordingly.
How I did it
Iterate all configured PG buffers for all ports and find the max index.
Build the output table according to the max index.
How to verify it
Run test "iface_namingmode/test_iface_namingmode.py" including this PR: sonic-net/sonic-swss#2143 and observe it passes.
Previous command output (if the output of a command-line utility has changed)
New command output (if the output of a command-line utility has changed)