Original file line number Diff line number Diff line change
Expand Up @@ -4,6 +4,22 @@

All notable changes to `homekit-ratgdo32` will be documented in this file. This project tries to adhere to [Semantic Versioning](http://semver.org/).

## v3.0.6 (2025-01-17)

### What's Changed

* Bugfix: Crash in esp_timer.c possibly related to multi-thread use of Ticker for LED timer (Issue #30).
* Bugfix: Motion sensor status should not show if there is no motion sensor.
* Bugfix: Crash reported at end of time-to-close delay (Issue #32).
* Bugfix: Could not set vehicle threshold above 200cm
* Feature: Set default time-to-close delay to 5 seconds and add warning if user selects lower value (Issue #33).
* Feature: Dynamically create HomeKit QR setup ID, and QR code graphic for pairing.
* Other: Updated HomeSpan library to version 2.1.1.

### Known Issues

* Still testing... Future updates MAY include breaking changes requiring a flash erase and re-upload.

## v3.0.5 (2025-01-05)

### What's Changed
Expand Down
6 changes: 5 additions & 1 deletion README.md
Original file line number Diff line number Diff line change
Expand Up @@ -133,7 +133,11 @@ This updates the name reported to HomeKit and for mDNS device discovery. The de

### Door Close Delay

You can select up-to 60 second delay before door starts closing. During the delay period the garage door lights will flash and you may hear the relay clicking. On ratgdo32-disco boards you will also hear an audible beep.
You can select up-to 60 second delay before door starts closing. During the delay period the garage door lights will flash and you may hear the relay clicking. On ratgdo32-disco boards you will also hear audible beeping. Default time-to-close delay is 5 seconds.

> [!WARNING]
> The US Consumer Product Safety Act Regulations, section 1211.14, unattended operation requirements [16 CFR § 1211.14](https://www.law.cornell.edu/cfr/text/16/1211.14), state that there must be a minimum delay of 5 seconds before the door closes.
> The regulation also requires that the light flash with audible beeping. If you select a time-to-close delay of under 5 seconds then a warning is shown in the web settings page and you accept all responsibility and liability for injury or any other loss.
### Require Password