Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Temperature not updating, but humidity does #98

Closed
luvxinh opened this issue May 30, 2024 · 6 comments
Closed

Temperature not updating, but humidity does #98

luvxinh opened this issue May 30, 2024 · 6 comments

Comments

@luvxinh
Copy link

luvxinh commented May 30, 2024

Screenshot_20240529_194043_Home Assistant.jpg

Screenshot_20240529_200659_Home Assistant.jpg

Screenshot_20240529_194037_Home Assistant.jpg

So in my case, the humidity reading is updated fine but the temperature reading does not update, unless I go into Manage zigbee device and force update, then it would have the new reading but then again, no update from then.

@pvvx
Copy link
Owner

pvvx commented May 30, 2024

image

@luvxinh
Copy link
Author

luvxinh commented May 30, 2024

I got this.
image

Also this is in the log.

Logger: homeassistant.components.zha.core.cluster_handlers
Source: components/zha/core/cluster_handlers/init.py:560
integration: Zigbee Home Automation (documentation, issues)
First occurred: 11:54:58 (2 occurrences)
Last logged: 11:54:58

[0xAF30:2:0x0300]: [Min mireds is 0, setting to 153] Please open an issue on the quirks repo to have this device corrected

I hope this can be of help

@pvvx
Copy link
Owner

pvvx commented May 30, 2024

[Min mireds is 0, setting to 153] Please open an issue on the quirks repo to have this device corrected

I don't have such a message.
The coordinator on EFR32MG21 is used.
image

@luvxinh
Copy link
Author

luvxinh commented Jun 10, 2024

I'm marking this as closed because after some time, the sensor ... updates. Frequency wise, it's haywire though ...

Still I appreciate the zigbee patch

@luvxinh luvxinh closed this as completed Jun 10, 2024
@luvxinh
Copy link
Author

luvxinh commented Aug 20, 2024

Hi

Just want to clear the confusion for anyone reading ... it was not because the sensor did not update, but rather the temperature did not change for more than 0.5 degree celcius, so the readings in ZHA did not update... took me a while to realize that.

Thanks for the firmware.

@pvvx
Copy link
Owner

pvvx commented Aug 20, 2024

If there has been no change for 0.5C (1%), ZHA sets the update time to 900 seconds by default.

ZHA does not provide any settings. All settings values ​​are written in the program code as the authors of ZHA wanted and without a patch nothing can be fixed...

Z2M has its own problems and significantly more when connecting new devices.
More problems - more questions - more popularity - more time spent by users searching for solutions that do not exist - more messages on the Internet.