Skip to content

Commit

Permalink
[fronius] Add the new channels to the documentation (openhab#12394)
Browse files Browse the repository at this point in the history
* [fronius] Document the recently added inverter power and soc channels

Signed-off-by: Jimmy Tanagra <[email protected]>
  • Loading branch information
jimtng authored and psmedley committed Feb 23, 2023
1 parent 799d122 commit 09076a6
Showing 1 changed file with 43 additions and 38 deletions.
81 changes: 43 additions & 38 deletions bundles/org.openhab.binding.fronius/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -15,9 +15,8 @@ It supports Fronius inverters and Fronius Smart Meter. Supports:
| --------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| `bridge` | The Bridge |
| `powerinverter` | Fronius Galvo, Symo and other Fronius inverters in combination with the Fronius Datamanager 1.0 / 2.0 or Fronius Datalogger. You can add multiple inverters that depend on the same datalogger with different device ids. (Default 1) |
| `meter` | Fronius Smart Meter. You can add multiple smart meters with different device ids. (The default id = 0)
| `ohmpilot` | Fronius Ohmpilot. (The default id = 0)

| `meter` | Fronius Smart Meter. You can add multiple smart meters with different device ids. (The default id = 0) |
| `ohmpilot` | Fronius Ohmpilot. (The default id = 0) |

## Discovery

Expand Down Expand Up @@ -50,30 +49,33 @@ The binding has no configuration options, all configuration is done at `bridge`,

### Ohmpilot Thing Configuration

| Parameter | Description |
| ---------- | ----------------------------------------------- |
| Parameter | Description |
| ---------- | -------------------------------------------- |
| `deviceId` | The identifier of your ohmpilot (Default: 0) |

## Channels

### Channels for `powerinverter` Thing

| Channel ID | Item Type | Description |
| ------------------------------------ | --------- | ----------------------------------------------------------------------------------------------------------------- |
| `inverterdatachanneldayenergy` | Number | Energy generated on current day |
| `inverterdatachannelpac` | Number | AC power |
| `inverterdatachanneltotal` | Number | Energy generated overall |
| `inverterdatachannelyear` | Number | Energy generated in current year |
| `inverterdatachannelfac` | Number | AC frequency |
| `inverterdatachanneliac` | Number | AC current |
| `inverterdatachannelidc` | Number | DC current |
| `inverterdatachanneluac` | Number | AC voltage |
| `inverterdatachanneludc` | Number | DC voltage |
| `inverterdatadevicestatuserrorcode` | Number | Device error code |
| `inverterdatadevicestatusstatuscode` | Number | Device status code<br />`0` - `6` Startup<br />`7` Running <br />`8` Standby<br />`9` Bootloading<br />`10` Error |
| `powerflowchannelpgrid` | Number | Power + from grid, - to grid |
| `powerflowchannelpload` | Number | Power + generator, - consumer |
| `powerflowchannelpakku` | Number | Power + charge, - discharge |
| Channel ID | Item Type | Description |
| ------------------------------------ | -------------------- | ----------------------------------------------------------------------------------------------------------------- |
| `inverterdatachanneldayenergy` | Number | Energy generated on current day |
| `inverterdatachannelpac` | Number | AC power |
| `inverterdatachanneltotal` | Number | Energy generated overall |
| `inverterdatachannelyear` | Number | Energy generated in current year |
| `inverterdatachannelfac` | Number | AC frequency |
| `inverterdatachanneliac` | Number | AC current |
| `inverterdatachannelidc` | Number | DC current |
| `inverterdatachanneluac` | Number | AC voltage |
| `inverterdatachanneludc` | Number | DC voltage |
| `inverterdatadevicestatuserrorcode` | Number | Device error code |
| `inverterdatadevicestatusstatuscode` | Number | Device status code<br />`0` - `6` Startup<br />`7` Running <br />`8` Standby<br />`9` Bootloading<br />`10` Error |
| `powerflowchannelpgrid` | Number:Power | Power (+ from grid, - to grid) |
| `powerflowchannelpload` | Number:Power | Power (+ generator, - consumer) |
| `powerflowchannelpakku` | Number:Power | Power (+ charge, - discharge) |
| `powerflowchannelppv` | Number:Power | Power (+ production) |
| `powerflowinverter1power` | Number:Power | Current power of inverter 1, null if not running (+ produce/export, - consume/import) |
| `powerflowinverter1soc` | Number:Dimensionless | Current state of charge of inverter 1 in percent |

### Channels for `meter` Thing

Expand All @@ -90,7 +92,7 @@ The binding has no configuration options, all configuration is done at `bridge`,
| `powerrealphase1` | Number:Power | Real Power on Phase 1 |
| `powerrealphase2` | Number:Power | Real Power on Phase 2 |
| `powerrealphase3` | Number:Power | Real Power on Phase 3 |
| `powerrealsum` | Number:Power | Real Power summed up |
| `powerrealsum` | Number:Power | Real Power summed up |
| `powerfactorphase1` | Number | Power Factor on Phase 1 |
| `powerfactorphase2` | Number | Power Factor on Phase 2 |
| `powerfactorphase3` | Number | Power Factor on Phase 3 |
Expand All @@ -101,30 +103,30 @@ The binding has no configuration options, all configuration is done at `bridge`,

### Channels for `ohmpilot` Thing

| Channel ID | Item Type | Description |
| ----------------------- | ------------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
| `energyrealsumconsumed` | Number:Energy | Real Energy consumed |
| `powerrealsum` | Number:Power | Real Power |
| `temperaturechannel1` | Number:Temperature | Temperature |
| `errorcode` | Number | Device error code |
| `statecode` | Number | Device state code<br />`0` up and running <br />`1` keep minimum temperature <br />`2` legionella protection <br />`3` critical fault<br />`4` fault<br />`5` boost mode |
| Channel ID | Item Type | Description |
| ----------------------- | ------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
| `energyrealsumconsumed` | Number:Energy | Real Energy consumed |
| `powerrealsum` | Number:Power | Real Power |
| `temperaturechannel1` | Number:Temperature | Temperature |
| `errorcode` | Number | Device error code |
| `statecode` | Number | Device state code<br />`0` up and running <br />`1` keep minimum temperature <br />`2` legionella protection <br />`3` critical fault<br />`4` fault<br />`5` boost mode |
| |


## Properties

### The `meter` thing has the following properties:

| Property | Description |
| -------- | ------------------------------ |
| `modelId` | The model name of the meter |
| Property | Description |
| -------------- | ------------------------------ |
| `modelId` | The model name of the meter |
| `serialNumber` | The serial number of the meter |

### The `ohmpilot` thing has the following property:

| Property | Description |
| -------- | ------------------------------ |
| `modelId` | The model name of the ohmpilot |
| Property | Description |
| -------------- | --------------------------------- |
| `modelId` | The model name of the ohmpilot |
| `serialNumber` | The serial number of the ohmpilot |

## Full Example
Expand Down Expand Up @@ -153,9 +155,12 @@ Number UAC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachan
Number UDC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneludc" }
Number ErrorCode { channel="fronius:powerinverter:mybridge:myinverter:inverterdatadevicestatuserrorcode" }
Number StatusCode { channel="fronius:powerinverter:mybridge:myinverter:inverterdatadevicestatusstatuscode" }
Number Grid_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpgrid" }
Number Load_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpload" }
Number Battery_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpakku" }
Number:Power Grid_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpgrid" }
Number:Power Load_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpload" }
Number:Power Battery_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpakku" }
Number:Power Production_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelppv" }
Number:Power Inverter1_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowinverter1power" }
Number:Dimensionless Inverter1_SOC { channel="fronius:powerinverter:mybridge:myinverter:powerflowinverter1soc" }
Number Meter_Enable { channel="fronius:meter:mybridge:mymeter:enable" }
Number Meter_Location { channel="fronius:meter:mybridge:mymeter:location" }
Expand Down

0 comments on commit 09076a6

Please sign in to comment.