Notifications
You must be signed in to change notification settings - Fork 2.1k
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
DM XML: Add device types to script and re-gen (#30387)
* DM XML: Add device types to script and re-gen * Address review comments, use new scraper, add version * Use old scraper version
- Loading branch information
Showing
70 changed files
with
6,500 additions
and
34 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,73 @@ | ||
<?xml version="1.0"?> | ||
<!-- | ||
Copyright (C) Connectivity Standards Alliance (2021). All rights reserved. | ||
The information within this document is the property of the Connectivity | ||
Standards Alliance and its use and disclosure are restricted, except as | ||
expressly set forth herein. | ||
Connectivity Standards Alliance hereby grants you a fully-paid, non-exclusive, | ||
nontransferable, worldwide, limited and revocable license (without the right to | ||
sublicense), under Connectivity Standards Alliance's applicable copyright | ||
rights, to view, download, save, reproduce and use the document solely for your | ||
own internal purposes and in accordance with the terms of the license set forth | ||
herein. This license does not authorize you to, and you expressly warrant that | ||
you shall not: (a) permit others (outside your organization) to use this | ||
document; (b) post or publish this document; (c) modify, adapt, translate, or | ||
otherwise change this document in any manner or create any derivative work | ||
based on this document; (d) remove or modify any notice or label on this | ||
document, including this Copyright Notice, License and Disclaimer. The | ||
Connectivity Standards Alliance does not grant you any license hereunder other | ||
than as expressly stated herein. | ||
Elements of this document may be subject to third party intellectual property | ||
rights, including without limitation, patent, copyright or trademark rights, | ||
and any such third party may or may not be a member of the Connectivity | ||
Standards Alliance. Connectivity Standards Alliance members grant other | ||
Connectivity Standards Alliance members certain intellectual property rights as | ||
set forth in the Connectivity Standards Alliance IPR Policy. Connectivity | ||
Standards Alliance members do not grant you any rights under this license. The | ||
Connectivity Standards Alliance is not responsible for, and shall not be held | ||
responsible in any manner for, identifying or failing to identify any or all | ||
such third party intellectual property rights. Please visit www.csa-iot.org for | ||
more information on how to become a member of the Connectivity Standards | ||
Alliance. | ||
This document and the information contained herein are provided on an “AS IS” | ||
basis and the Connectivity Standards Alliance DISCLAIMS ALL WARRANTIES EXPRESS | ||
OR IMPLIED, INCLUDING BUT NOT LIMITED TO (A) ANY WARRANTY THAT THE USE OF THE | ||
INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OF THIRD PARTIES (INCLUDING | ||
WITHOUT LIMITATION ANY INTELLECTUAL PROPERTY RIGHTS INCLUDING PATENT, COPYRIGHT | ||
OR TRADEMARK RIGHTS); OR (B) ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS | ||
FOR A PARTICULAR PURPOSE, TITLE OR NONINFRINGEMENT. IN NO EVENT WILL THE | ||
CONNECTIVITY STANDARDS ALLIANCE BE LIABLE FOR ANY LOSS OF PROFITS, LOSS OF | ||
BUSINESS, LOSS OF USE OF DATA, INTERRUPTION OF BUSINESS, OR FOR ANY OTHER | ||
DIRECT, INDIRECT, SPECIAL OR EXEMPLARY, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL | ||
DAMAGES OF ANY KIND, IN CONTRACT OR IN TORT, IN CONNECTION WITH THIS DOCUMENT | ||
OR THE INFORMATION CONTAINED HEREIN, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH | ||
LOSS OR DAMAGE. | ||
All company, brand and product names in this document may be trademarks that | ||
are the sole property of their respective owners. | ||
This notice and disclaimer must be included on all copies of this document. | ||
Connectivity Standards Alliance | ||
508 Second Street, Suite 206 | ||
Davis, CA 95616, USA | ||
--> | ||
<deviceType xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="types types.xsd devicetype devicetype.xsd" id="0x000e" name="Aggregator" revision="1"> | ||
<revisionHistory> | ||
<revision revision="0" summary="Represents device definitions prior to device type revision numbers"/> | ||
<revision revision="1" summary="Initial release of this document"/> | ||
</revisionHistory> | ||
<classification class="dynamic utility" scope="endpoint"/> | ||
<conditions/> | ||
<clusters> | ||
<cluster id="0x0003" name="Identify" side="server"> | ||
<optionalConform/> | ||
</cluster> | ||
<cluster id="0x0025" name="Actions" side="server"> | ||
<optionalConform/> | ||
</cluster> | ||
</clusters> | ||
</deviceType> |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,108 @@ | ||
<?xml version="1.0"?> | ||
<!-- | ||
Copyright (C) Connectivity Standards Alliance (2023). All rights reserved. | ||
The information within this document is the property of the Connectivity | ||
Standards Alliance and its use and disclosure are restricted, except as | ||
expressly set forth herein. | ||
Connectivity Standards Alliance hereby grants you a fully-paid, non-exclusive, | ||
nontransferable, worldwide, limited and revocable license (without the right to | ||
sublicense), under Connectivity Standards Alliance's applicable copyright | ||
rights, to view, download, save, reproduce and use the document solely for your | ||
own internal purposes and in accordance with the terms of the license set forth | ||
herein. This license does not authorize you to, and you expressly warrant that | ||
you shall not: (a) permit others (outside your organization) to use this | ||
document; (b) post or publish this document; (c) modify, adapt, translate, or | ||
otherwise change this document in any manner or create any derivative work | ||
based on this document; (d) remove or modify any notice or label on this | ||
document, including this Copyright Notice, License and Disclaimer. The | ||
Connectivity Standards Alliance does not grant you any license hereunder other | ||
than as expressly stated herein. | ||
Elements of this document may be subject to third party intellectual property | ||
rights, including without limitation, patent, copyright or trademark rights, | ||
and any such third party may or may not be a member of the Connectivity | ||
Standards Alliance. Connectivity Standards Alliance members grant other | ||
Connectivity Standards Alliance members certain intellectual property rights as | ||
set forth in the Connectivity Standards Alliance IPR Policy. Connectivity | ||
Standards Alliance members do not grant you any rights under this license. The | ||
Connectivity Standards Alliance is not responsible for, and shall not be held | ||
responsible in any manner for, identifying or failing to identify any or all | ||
such third party intellectual property rights. Please visit www.csa-iot.org for | ||
more information on how to become a member of the Connectivity Standards | ||
Alliance. | ||
This document and the information contained herein are provided on an “AS IS” | ||
basis and the Connectivity Standards Alliance DISCLAIMS ALL WARRANTIES EXPRESS | ||
OR IMPLIED, INCLUDING BUT NOT LIMITED TO (A) ANY WARRANTY THAT THE USE OF THE | ||
INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OF THIRD PARTIES (INCLUDING | ||
WITHOUT LIMITATION ANY INTELLECTUAL PROPERTY RIGHTS INCLUDING PATENT, COPYRIGHT | ||
OR TRADEMARK RIGHTS); OR (B) ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS | ||
FOR A PARTICULAR PURPOSE, TITLE OR NONINFRINGEMENT. IN NO EVENT WILL THE | ||
CONNECTIVITY STANDARDS ALLIANCE BE LIABLE FOR ANY LOSS OF PROFITS, LOSS OF | ||
BUSINESS, LOSS OF USE OF DATA, INTERRUPTION OF BUSINESS, OR FOR ANY OTHER | ||
DIRECT, INDIRECT, SPECIAL OR EXEMPLARY, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL | ||
DAMAGES OF ANY KIND, IN CONTRACT OR IN TORT, IN CONNECTION WITH THIS DOCUMENT | ||
OR THE INFORMATION CONTAINED HEREIN, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH | ||
LOSS OR DAMAGE. | ||
All company, brand and product names in this document may be trademarks that | ||
are the sole property of their respective owners. | ||
This notice and disclaimer must be included on all copies of this document. | ||
Connectivity Standards Alliance | ||
508 Second Street, Suite 206 | ||
Davis, CA 95616, USA | ||
--> | ||
<deviceType xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="types types.xsd devicetype devicetype.xsd" id="0x002c" name="Air Quality Sensor" revision="1"> | ||
<revisionHistory> | ||
<revision revision="1" summary="Initial release of this document"/> | ||
</revisionHistory> | ||
<classification class="simple" scope="endpoint"/> | ||
<conditions/> | ||
<clusters> | ||
<cluster id="0x0003" name="Identify" side="server"> | ||
<mandatoryConform/> | ||
</cluster> | ||
<cluster id="0x005b" name="Air Quality" side="server"> | ||
<mandatoryConform/> | ||
</cluster> | ||
<cluster id="0x0402" name="Temperature Measurement" side="server"> | ||
<optionalConform/> | ||
</cluster> | ||
<cluster id="0x0405" name="Relative Humidity Measurement" side="server"> | ||
<optionalConform/> | ||
</cluster> | ||
<cluster id="0x040c" name="Carbon Monoxide Concentration Measurement" side="server"> | ||
<optionalConform/> | ||
</cluster> | ||
<cluster id="0x040d" name="Carbon Dioxide Concentration Measurement" side="server"> | ||
<optionalConform/> | ||
</cluster> | ||
<cluster id="0x0413" name="Nitrogen Dioxide Concentration Measurement" side="server"> | ||
<optionalConform/> | ||
</cluster> | ||
<cluster id="0x0415" name="Ozone Concentration Measurement" side="server"> | ||
<optionalConform/> | ||
</cluster> | ||
<cluster id="0x042a" name="PM2.5 Concentration Measurement" side="server"> | ||
<optionalConform/> | ||
</cluster> | ||
<cluster id="0x042b" name="Formaldehyde Concentration Measurement" side="server"> | ||
<optionalConform/> | ||
</cluster> | ||
<cluster id="0x042c" name="PM1 Concentration Measurement" side="server"> | ||
<optionalConform/> | ||
</cluster> | ||
<cluster id="0x042d" name="PM10 Concentration Measurement" side="server"> | ||
<optionalConform/> | ||
</cluster> | ||
<cluster id="0x042e" name="Total Volatile Organic Compounds Concentration Measurement" side="server"> | ||
<optionalConform/> | ||
</cluster> | ||
<cluster id="0x042f" name="Radon Concentration Measurement" side="server"> | ||
<optionalConform/> | ||
</cluster> | ||
</clusters> | ||
</deviceType> |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,65 @@ | ||
<?xml version="1.0"?> | ||
<!-- | ||
Copyright (C) Connectivity Standards Alliance (2021). All rights reserved. | ||
The information within this document is the property of the Connectivity | ||
Standards Alliance and its use and disclosure are restricted, except as | ||
expressly set forth herein. | ||
Connectivity Standards Alliance hereby grants you a fully-paid, non-exclusive, | ||
nontransferable, worldwide, limited and revocable license (without the right to | ||
sublicense), under Connectivity Standards Alliance's applicable copyright | ||
rights, to view, download, save, reproduce and use the document solely for your | ||
own internal purposes and in accordance with the terms of the license set forth | ||
herein. This license does not authorize you to, and you expressly warrant that | ||
you shall not: (a) permit others (outside your organization) to use this | ||
document; (b) post or publish this document; (c) modify, adapt, translate, or | ||
otherwise change this document in any manner or create any derivative work | ||
based on this document; (d) remove or modify any notice or label on this | ||
document, including this Copyright Notice, License and Disclaimer. The | ||
Connectivity Standards Alliance does not grant you any license hereunder other | ||
than as expressly stated herein. | ||
Elements of this document may be subject to third party intellectual property | ||
rights, including without limitation, patent, copyright or trademark rights, | ||
and any such third party may or may not be a member of the Connectivity | ||
Standards Alliance. Connectivity Standards Alliance members grant other | ||
Connectivity Standards Alliance members certain intellectual property rights as | ||
set forth in the Connectivity Standards Alliance IPR Policy. Connectivity | ||
Standards Alliance members do not grant you any rights under this license. The | ||
Connectivity Standards Alliance is not responsible for, and shall not be held | ||
responsible in any manner for, identifying or failing to identify any or all | ||
such third party intellectual property rights. Please visit www.csa-iot.org for | ||
more information on how to become a member of the Connectivity Standards | ||
Alliance. | ||
This document and the information contained herein are provided on an “AS IS” | ||
basis and the Connectivity Standards Alliance DISCLAIMS ALL WARRANTIES EXPRESS | ||
OR IMPLIED, INCLUDING BUT NOT LIMITED TO (A) ANY WARRANTY THAT THE USE OF THE | ||
INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OF THIRD PARTIES (INCLUDING | ||
WITHOUT LIMITATION ANY INTELLECTUAL PROPERTY RIGHTS INCLUDING PATENT, COPYRIGHT | ||
OR TRADEMARK RIGHTS); OR (B) ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS | ||
FOR A PARTICULAR PURPOSE, TITLE OR NONINFRINGEMENT. IN NO EVENT WILL THE | ||
CONNECTIVITY STANDARDS ALLIANCE BE LIABLE FOR ANY LOSS OF PROFITS, LOSS OF | ||
BUSINESS, LOSS OF USE OF DATA, INTERRUPTION OF BUSINESS, OR FOR ANY OTHER | ||
DIRECT, INDIRECT, SPECIAL OR EXEMPLARY, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL | ||
DAMAGES OF ANY KIND, IN CONTRACT OR IN TORT, IN CONNECTION WITH THIS DOCUMENT | ||
OR THE INFORMATION CONTAINED HEREIN, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH | ||
LOSS OR DAMAGE. | ||
All company, brand and product names in this document may be trademarks that | ||
are the sole property of their respective owners. | ||
This notice and disclaimer must be included on all copies of this document. | ||
Connectivity Standards Alliance | ||
508 Second Street, Suite 206 | ||
Davis, CA 95616, USA | ||
--> | ||
<deviceType xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="types types.xsd devicetype devicetype.xsd" id="" name="Base Device Type" revision="2"> | ||
<revisionHistory> | ||
<revision revision="0" summary="Represents device definitions prior to device type revision numbers"/> | ||
<revision revision="1" summary="Initial release of this document"/> | ||
<revision revision="2" summary="Duplicate condition replaces Multiple condition"/> | ||
</revisionHistory> | ||
<conditions/> | ||
</deviceType> |