Merge pull request #1331 from cdjackson/zwave-WD500Z
[Z-Wave] Add initial version of WD500Z to database
- Loading branch information
Showing
2 changed files
with
187 additions
and
0 deletions.
There are no files selected for viewing
174 changes: 174 additions & 0 deletions
174
bundles/binding/org.openhab.binding.zwave/database/linear/wdz500-1.xml
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,174 @@ | ||
<?xml version="1.0" encoding="utf-8"?> | ||
<Product> | ||
<Model>WD500Z</Model> | ||
<Label lang="en"> Wall Dimmer Switch</Label> | ||
<CommandClasses> | ||
<Class> | ||
<id>0x20</id> | ||
</Class> | ||
<Class> | ||
<id>0x26</id> | ||
</Class> | ||
<Class> | ||
<id>0x27</id> | ||
</Class> | ||
<Class> | ||
<id>0x2b</id> | ||
</Class> | ||
<Class> | ||
<id>0x2c</id> | ||
</Class> | ||
<Class> | ||
<id>0x70</id> | ||
</Class> | ||
<Class> | ||
<id>0x72</id> | ||
</Class> | ||
<Class> | ||
<id>0x73</id> | ||
</Class> | ||
<Class> | ||
<id>0x85</id> | ||
</Class> | ||
<Class> | ||
<id>0x86</id> | ||
</Class> | ||
</CommandClasses> | ||
<Configuration> | ||
<Parameter> | ||
<Index>1</Index> | ||
<Type>list</Type> | ||
<Default>1</Default> | ||
<Size>1</Size> | ||
<Label lang="en">Dim Start Level</Label> | ||
<Help lang="en">A dimmer receiving this command will start dimming | ||
from that start level if this bit is set to 0. If the bit is set to | ||
1, the dimmer will ignore the start level and instead start dimming | ||
from its current level.</Help> | ||
<Item> | ||
<Value>0</Value> | ||
<Label lang="en">Use Start Level</Label> | ||
</Item> | ||
<Item> | ||
<Value>1</Value> | ||
<Label lang="en">Ignore Start Level</Label> | ||
</Item> | ||
</Parameter> | ||
<Parameter> | ||
<Index>3</Index> | ||
<Type>list</Type> | ||
<Default>0</Default> | ||
<Size>1</Size> | ||
<Label lang="en">LED Indication</Label> | ||
<Help lang="en">The WD500Z-1 will flicker its LED when it is | ||
transmitting to any of its groups. This can be changed if desired. | ||
</Help> | ||
<Item> | ||
<Value>0</Value> | ||
<Label lang="en">0</Label> | ||
</Item> | ||
<Item> | ||
<Value>1</Value> | ||
<Label lang="en">1</Label> | ||
</Item> | ||
</Parameter> | ||
<Parameter> | ||
<Index>4</Index> | ||
<Type>list</Type> | ||
<Default>0</Default> | ||
<Size>1</Size> | ||
<Label lang="en">Invert Switch</Label> | ||
<Help lang="en">To change the top of the switch to OFF and the bottom | ||
to ON change parameter to 1.</Help> | ||
<Item> | ||
<Value>0</Value> | ||
<Label lang="en">Top-ON, Bottom-OFF </Label> | ||
</Item> | ||
<Item> | ||
<Value>1</Value> | ||
<Label lang="en">Bottom-ON, Top-OFF</Label> | ||
</Item> | ||
</Parameter> | ||
<Parameter> | ||
<Index>14</Index> | ||
<Type>list</Type> | ||
<Default>0</Default> | ||
<Size>1</Size> | ||
<Label lang="en">Enable Shade Control Group 2</Label> | ||
<Help lang="en">The switch can control shade control devices if this | ||
parameter is set to 1</Help> | ||
<Item> | ||
<Value>0</Value> | ||
<Label lang="en">Disable</Label> | ||
</Item> | ||
<Item> | ||
<Value>1</Value> | ||
<Label lang="en">Enable</Label> | ||
</Item> | ||
</Parameter> | ||
<Parameter> | ||
<Index>15</Index> | ||
<Type>list</Type> | ||
<Default>0</Default> | ||
<Size>1</Size> | ||
<Label lang="en">Enable Shade Control Group 3</Label> | ||
<Help lang="en">The switch can control shade control devices if this | ||
parameter is set to 1.</Help> | ||
<Item> | ||
<Value>0</Value> | ||
<Label lang="en">Disable</Label> | ||
</Item> | ||
<Item> | ||
<Value>1</Value> | ||
<Label lang="en">Enable</Label> | ||
</Item> | ||
</Parameter> | ||
<Parameter> | ||
<Index>19</Index> | ||
<Type>list</Type> | ||
<Default>2</Default> | ||
<Size>1</Size> | ||
<Label lang="en">LED Transmission Indication</Label> | ||
<Help lang="en">The WD500Z-1 will flicker its LED when it is | ||
transmitting to any of its groups. Parameter set to 0 = not flicker | ||
Parameter set to 1 = flicker the entire time of transmitting | ||
Parameter set to 2 = flicker for only 1 second.</Help> | ||
<Item> | ||
<Value>0</Value> | ||
<Label lang="en">Disable Flicker</Label> | ||
</Item> | ||
<Item> | ||
<Value>1</Value> | ||
<Label lang="en">Flicker while transmitting</Label> | ||
</Item> | ||
<Item> | ||
<Value>2</Value> | ||
<Label lang="en">Flicker for 1 second</Label> | ||
</Item> | ||
</Parameter> | ||
</Configuration> | ||
|
||
<Associations> | ||
<Group> | ||
<Index>1</Index> | ||
<Maximum>5</Maximum> | ||
<Label lang="en">UNKNOWN!!!</Label> | ||
</Group> | ||
<Group> | ||
<Index>2</Index> | ||
<Maximum>5</Maximum> | ||
<Label lang="en">Double Tap</Label> | ||
<Help lang="en">Turn devices on an off by tapping the top or the | ||
bottom of the switch twice. Brighten or dim devices by tapping and | ||
then hold the top or the bottom of the switch.</Help> | ||
</Group> | ||
<Group> | ||
<Index>3</Index> | ||
<Maximum>5</Maximum> | ||
<Label lang="en">Triple Tap</Label> | ||
<Help lang="en"> Turn devices on an off by tapping the top or the | ||
bottom of the switch three times. Brighten or dim devices by tapping | ||
twice and then hold the top or the bottom of the switch.</Help> | ||
</Group> | ||