Notifications
You must be signed in to change notification settings - Fork 17
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
- Loading branch information
Showing
2 changed files
with
152 additions
and
4 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
|
@@ -24,10 +24,84 @@ | |
|
||
|
||
# Release Features(s) | ||
* TBD | ||
|
||
* <b><i>Ixia Chassis & Appliances(Novus, AresOne)</i></b>: Support added for new traffic applying infrastructure. | ||
- Instead of <b><i>"Failed to apply flow configurations due to: Please contact Ixia Support."</i></b> , | ||
- In scenarios where underlying hardware module doesn't have the resources to apply the flow a proper error message such as <b><i>"Failed to apply flow configurations due to: Error occurred for flow 'ipv6flowlabel': The Tx Ports of the flow do not support the combinations of fields and size of value lists configured. Please reduce the size of the value lists or/and fields with value lists configured or use a load module ( or variant) with more resources."</i></b> Based on this either test can be modified or appropriate load modules can be used for the test. | ||
- There were certain scenarios with large `values` in packet fields in the flows which were failing with above error inspite of being within the modules capabilities and can now be applied without any error. | ||
- Earlier configuration with multiples flows with large `values` in packet fields would fail with error as <b><i>"Failed to apply flow configurations due to: Traffic configuration exceeds port background memory size."</i></b>. This issue is also fixed with the upgrade to new traffic applying infrastructure. | ||
- Issue where correct `values`/`increment`/`decrement` for `ethernet.src/dst` was not being transmitted on the wire is fixed. | ||
- In this new infrastructure, traffic will be directly applied to the hardware ports resulting in better performance on `set_transmit_state`. | ||
|
||
* <b><i>gosnappi</i></b>: Client side file organization of the `gosnappi` sdk is modified to allow for better auto-completion support when writing test programs. | ||
Note: Client must be upgraded to gosnappi [v1.7.2](https://pkg.go.dev/github.com/open-traffic-generator/snappi/[email protected]). | ||
|
||
* <b><i>Ixia-C, UHD400</i></b>: Support added for DHCPv4 Client and Server in control plane. [details](https://github.com/open-traffic-generator/models/pull/371) | ||
- User will be the able to configure DHCPv4 Client and Server by the following code snippet. More comprehensive [B2B example](https://github.com/open-traffic-generator/featureprofiles/blob/dev-dhcp/feature/dhcp/dhcpv4_client_server_b2b_test.go) | ||
```go | ||
// Configure a DHCP Client | ||
dhcpclient := d1Eth1.Dhcpv4Interfaces().Add(). | ||
SetName("p1d1dhcpv41") | ||
|
||
dhcpclient.FirstServer() | ||
dhcpclient.ParametersRequestList(). | ||
SetSubnetMask(true). | ||
SetRouter(true). | ||
SetRenewalTimer(true) | ||
|
||
// Configure a DHCP Server | ||
d2Dhcpv4Server := d2.DhcpServer().Ipv4Interfaces().Add(). | ||
SetName("p2d1dhcpv4server") | ||
|
||
d2Dhcpv4Server.SetIpv4Name("p2d1ipv4").AddressPools(). | ||
Add().SetName("pool1"). | ||
SetLeaseTime(3600). | ||
SetStartAddress("100.1.100.1"). | ||
SetStep(1). | ||
SetCount(1). | ||
SetPrefixLength(16).Options().SetRouterAddress("100.1.0.1").SetEchoRelayWithTlv82(true) | ||
``` | ||
* <b><i>Ixia-C, Ixia Chassis & Appliances(Novus, AresOne), UHD400</i></b>: Support added for `random` in following flow fields. [details](https://github.com/open-traffic-generator/models/pull/380) | ||
- `ipv4.src/dst` | ||
- `ipv6.flow_label` | ||
- `tcp.src_port/dst_port` | ||
- `udp.src_port/dst_port` | ||
|
||
- User can configure by using following snippet. | ||
```go | ||
ipv6 := flow1.Packet().Add().Ipv6() | ||
ipv6.FlowLabel().Random().SetMin(1).SetMax(1048574).SetCount(250000).SetSeed(1) | ||
``` | ||
Note: For <b><i>UHD400</i></b> an intermittent issue is present on using `random`, where `rx` fields of `flow_metrics` can return zero values. | ||
|
||
|
||
* <b><i>Ixia-C</i></b>: New environment variable `OPT_ADAPTIVE_CPU_USAGE=""` is introduced for docker based ixia-c-traffic-engine setups which enables adaptive CPU usage on the `rx` port for a flow. By default a non adaptive receiver is used when the `rx` CPU core usage reaches up to 100%. The adaptive receiver reduces `rx` CPU core usage from 100% to less than 5% in idle mode. To disable the adaptive receiver please remove this environment variable from docker run command. It is recommended to also pin the `rx` to specific cpu cores using the `ARG_CORE_LIST` environment variable when enabling `OPT_ADAPTIVE_CPU_USAGE`. | ||
|
||
- Example docker usage: | ||
|
||
```yml | ||
docker run --net=host --privileged --rm -d \ | ||
-e OPT_LISTEN_PORT="5555" \ | ||
-e ARG_CORE_LIST="1 2 3" \ | ||
-e ARG_IFACE_LIST="virtual@af_packet,enp7s0" \ | ||
-e OPT_NO_HUGEPAGES="Yes" \ | ||
-e OPT_ADAPTIVE_CPU_USAGE="" \ | ||
--name ixia-c-traffic-engine \ | ||
ixia-c-traffic-engine:1.8.0.25 | ||
``` | ||
|
||
### Bug Fix(s) | ||
* TBD | ||
* <b><i>Ixia Chassis & Appliances(Novus, AresOne)</i></b>: Issue where `flow_metrics` were not being returned within timeout resulting in <b><i>"Could not send message, error: unexpected queue Get(1) error: queue: disposed" and "Stats may be inconsistent"</i></b> error is fixed. | ||
|
||
* <b><i>Ixia Chassis & Appliances(Novus, AresOne)</i></b>: Issue where BGP/BGP+ learned information containing `origin` of type `incomplete` was not being returned properly by `get_states` is fixed. This would result in deserialization error while accessing BGP/BGP+ learned information using `otg-gNMI-server`. | ||
|
||
* <b><i>Ixia Chassis & Appliances(AresOne)</i></b>: Issue where `port_metrics` were not available when load module of type `1 x 400G AresOne-M` with transceiver of type `800GE LAN QSFP-DD` was being used, is fixed. | ||
|
||
* <b><i>Ixia Chassis & Appliances(AresOne)</i></b>: Issue where `set_control_state.protocol.route.state=withdraw/advertise` is triggered with an empty `names` field, all configured route ranges were being not withdrawn or advertised, is fixed. | ||
|
||
* <b><i>Ixia Chassis & Appliances(AresOne)</i></b>: Issue where on `set_control_state.protocol.all.state=start`, a `l1` `up/down` event was triggered even when `l1` state was already `up`, is now fixed. | ||
|
||
Note: If port is in `down` state, it has to be brought back to `up` state before starting a test. | ||
|
||
|
||
#### Known Issues | ||
|
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
|
@@ -17,10 +17,84 @@ | |
|
||
|
||
# Release Features(s) | ||
* TBD | ||
|
||
* <b><i>Ixia Chassis & Appliances(Novus, AresOne)</i></b>: Support added for new traffic applying infrastructure. | ||
- Instead of <b><i>"Failed to apply flow configurations due to: Please contact Ixia Support."</i></b> , | ||
- In scenarios where underlying hardware module doesn't have the resources to apply the flow a proper error message such as <b><i>"Failed to apply flow configurations due to: Error occurred for flow 'ipv6flowlabel': The Tx Ports of the flow do not support the combinations of fields and size of value lists configured. Please reduce the size of the value lists or/and fields with value lists configured or use a load module ( or variant) with more resources."</i></b> Based on this either test can be modified or appropriate load modules can be used for the test. | ||
- There were certain scenarios with large `values` in packet fields in the flows which were failing with above error inspite of being within the modules capabilities and can now be applied without any error. | ||
- Earlier configuration with multiples flows with large `values` in packet fields would fail with error as <b><i>"Failed to apply flow configurations due to: Traffic configuration exceeds port background memory size."</i></b>. This issue is also fixed with the upgrade to new traffic applying infrastructure. | ||
- Issue where correct `values`/`increment`/`decrement` for `ethernet.src/dst` was not being transmitted on the wire is fixed. | ||
- In this new infrastructure, traffic will be directly applied to the hardware ports resulting in better performance on `set_transmit_state`. | ||
|
||
* <b><i>gosnappi</i></b>: Client side file organization of the `gosnappi` sdk is modified to allow for better auto-completion support when writing test programs. | ||
Note: Client must be upgraded to gosnappi [v1.7.2](https://pkg.go.dev/github.com/open-traffic-generator/snappi/[email protected]). | ||
|
||
* <b><i>Ixia-C, UHD400</i></b>: Support added for DHCPv4 Client and Server in control plane. [details](https://github.com/open-traffic-generator/models/pull/371) | ||
- User will be the able to configure DHCPv4 Client and Server by the following code snippet. More comprehensive [B2B example](https://github.com/open-traffic-generator/featureprofiles/blob/dev-dhcp/feature/dhcp/dhcpv4_client_server_b2b_test.go) | ||
```go | ||
// Configure a DHCP Client | ||
dhcpclient := d1Eth1.Dhcpv4Interfaces().Add(). | ||
SetName("p1d1dhcpv41") | ||
|
||
dhcpclient.FirstServer() | ||
dhcpclient.ParametersRequestList(). | ||
SetSubnetMask(true). | ||
SetRouter(true). | ||
SetRenewalTimer(true) | ||
|
||
// Configure a DHCP Server | ||
d2Dhcpv4Server := d2.DhcpServer().Ipv4Interfaces().Add(). | ||
SetName("p2d1dhcpv4server") | ||
|
||
d2Dhcpv4Server.SetIpv4Name("p2d1ipv4").AddressPools(). | ||
Add().SetName("pool1"). | ||
SetLeaseTime(3600). | ||
SetStartAddress("100.1.100.1"). | ||
SetStep(1). | ||
SetCount(1). | ||
SetPrefixLength(16).Options().SetRouterAddress("100.1.0.1").SetEchoRelayWithTlv82(true) | ||
``` | ||
* <b><i>Ixia-C, Ixia Chassis & Appliances(Novus, AresOne), UHD400</i></b>: Support added for `random` in following flow fields. [details](https://github.com/open-traffic-generator/models/pull/380) | ||
- `ipv4.src/dst` | ||
- `ipv6.flow_label` | ||
- `tcp.src_port/dst_port` | ||
- `udp.src_port/dst_port` | ||
|
||
- User can configure by using following snippet. | ||
```go | ||
ipv6 := flow1.Packet().Add().Ipv6() | ||
ipv6.FlowLabel().Random().SetMin(1).SetMax(1048574).SetCount(250000).SetSeed(1) | ||
``` | ||
Note: For <b><i>UHD400</i></b> an intermittent issue is present on using `random`, where `rx` fields of `flow_metrics` can return zero values. | ||
|
||
|
||
* <b><i>Ixia-C</i></b>: New environment variable `OPT_ADAPTIVE_CPU_USAGE=""` is introduced for docker based ixia-c-traffic-engine setups which enables adaptive CPU usage on the `rx` port for a flow. By default a non adaptive receiver is used when the `rx` CPU core usage reaches up to 100%. The adaptive receiver reduces `rx` CPU core usage from 100% to less than 5% in idle mode. To disable the adaptive receiver please remove this environment variable from docker run command. It is recommended to also pin the `rx` to specific cpu cores using the `ARG_CORE_LIST` environment variable when enabling `OPT_ADAPTIVE_CPU_USAGE`. | ||
|
||
- Example docker usage: | ||
|
||
```yml | ||
docker run --net=host --privileged --rm -d \ | ||
-e OPT_LISTEN_PORT="5555" \ | ||
-e ARG_CORE_LIST="1 2 3" \ | ||
-e ARG_IFACE_LIST="virtual@af_packet,enp7s0" \ | ||
-e OPT_NO_HUGEPAGES="Yes" \ | ||
-e OPT_ADAPTIVE_CPU_USAGE="" \ | ||
--name ixia-c-traffic-engine \ | ||
ixia-c-traffic-engine:1.8.0.25 | ||
``` | ||
|
||
### Bug Fix(s) | ||
* TBD | ||
* <b><i>Ixia Chassis & Appliances(Novus, AresOne)</i></b>: Issue where `flow_metrics` were not being returned within timeout resulting in <b><i>"Could not send message, error: unexpected queue Get(1) error: queue: disposed" and "Stats may be inconsistent"</i></b> error is fixed. | ||
|
||
* <b><i>Ixia Chassis & Appliances(Novus, AresOne)</i></b>: Issue where BGP/BGP+ learned information containing `origin` of type `incomplete` was not being returned properly by `get_states` is fixed. This would result in deserialization error while accessing BGP/BGP+ learned information using `otg-gNMI-server`. | ||
|
||
* <b><i>Ixia Chassis & Appliances(AresOne)</i></b>: Issue where `port_metrics` were not available when load module of type `1 x 400G AresOne-M` with transceiver of type `800GE LAN QSFP-DD` was being used, is fixed. | ||
|
||
* <b><i>Ixia Chassis & Appliances(AresOne)</i></b>: Issue where `set_control_state.protocol.route.state=withdraw/advertise` is triggered with an empty `names` field, all configured route ranges were being not withdrawn or advertised, is fixed. | ||
|
||
* <b><i>Ixia Chassis & Appliances(AresOne)</i></b>: Issue where on `set_control_state.protocol.all.state=start`, a `l1` `up/down` event was triggered even when `l1` state was already `up`, is now fixed. | ||
|
||
Note: If port is in `down` state, it has to be brought back to `up` state before starting a test. | ||
|
||
|
||
#### Known Issues | ||
|