This PR adds Lua commands to control the "sigma-delta" signal generator described in A first order sigma-delta signal from io pin source.
Documentation is a bit sparse and I had to derive most details with waveform scoping, though I hope that the API doc provides enough information of what to expect:
A hardware-driven pulse generator with 12.5 ns to 3.2 µs high (or low) duration and total period of 2x to 256x. It can be also operated as 8 bit PWM with fixed 312 kHz frequency. Any GPIO except pin 0 / GPIO16 is selectable as output.