Releases: matsstaff/stc1000p
Release v1.09
Release v1.08
Added FO433 and communication firmwares.
Release v1.07
Fix bug where every other profile had wrong limits.
Fix bug where temp probe switches after soft on.
Release v1.06
Add functionality for 2nd temp probe (to limit heating/cooling). Display 'OFF' in soft off mode. Added user definable temperature alarm. Added profile 'editor' webpage.
Release v1.05
Reset both heating and cooling delay when either heating or cooling cycle ends. Improved power off functionality, increased button debounce time, allow longer heating delays.
Release v1.04
One bugfix and a few minor improvements.
Updated usermanual for 64 substeps in ramping.
The bug was that when writing to EEPROM, global interrupts were not enabled again afterwards. This did not seem to matter much as interrupts are enabled/disabled every time LED's are updated, but now it is corrected anyway.
I added a wait for first A/D value to complete before initializing the filter, as it seemed like filter was not correctly initialized for some.
Added a bias to averaging (to correct rounding), I doubt it will matter much.
Release v1.03
Bugfix (interpolation overflow)
Added leaky integration A/D filtering
Improved interpolation
Release v1.02
Improved averaging
Release v1.01
Increased maximum number of steps for approximative ramping from 8 to 64.
STC-1000+ v1.00
This is the first release of STC-1000+. See user guide for more information.