Skip to content

Commit

Permalink
fix: Avoid incorrect reload of the commutation wait timer
Browse files Browse the repository at this point in the history
The bug affected wait when setting motor timing to high
  • Loading branch information
mathiasvr committed Mar 17, 2021
1 parent bfa615c commit a480fbf
Showing 1 changed file with 7 additions and 4 deletions.
11 changes: 7 additions & 4 deletions Bluejay.asm
Original file line number Diff line number Diff line change
Expand Up @@ -2276,19 +2276,22 @@ comp_exit:
;
; Setup commutation timing routine
;
; Sets up and starts wait from commutation to zero cross
; Clear the zero cross timeout and sets up wait from zero cross to commutation
;
;**** **** **** **** **** **** **** **** **** **** **** **** ****
setup_comm_wait:
clr IE_EA
anl EIE1, #7Fh ; Disable timer 3 interrupts

; It is necessary to update the timer reload registers before the timer registers,
; to avoid a reload of the previous values in case of a short Wt_Comm_Start delay.
mov TMR3RLL, Wt_Adv_Start_L ; Setup next wait time
mov TMR3RLH, Wt_Adv_Start_H
mov TMR3CN0, #00h ; Timer 3 disabled and interrupt flag cleared
mov TMR3L, Wt_Comm_Start_L
mov TMR3H, Wt_Comm_Start_H
mov TMR3CN0, #04h ; Timer 3 enabled and interrupt flag cleared
; Setup next wait time
mov TMR3RLL, Wt_Adv_Start_L
mov TMR3RLH, Wt_Adv_Start_H

setb Flag_Timer3_Pending
orl EIE1, #80h ; Enable timer 3 interrupts
setb IE_EA ; Enable interrupts again
Expand Down