Notifications
You must be signed in to change notification settings - Fork 101
Drive Select
Greaseweazle supports Shugart and IBM/PC multi-drive setups1.
The read and write commands both accept option --drive N
where N is one of A, B, 0, 1, or 2. Note that N
is not case sensitive: a and b are also accepted.
The default is A (IBM/PC Drive A) requiring an IBM/PC drive and a "cable with a twist" (see the explanation below). If your drive fails with a Track 0 not found error, you may have:
- A Shugart drive, strapped for DS0 (pin 10): Connect with straight ribbon and use
--drive 0
- A PC drive being used with a straight cable: Use
--drive b
Note: Greaseweazle F1 does not support multiple drives and any specified non-default drive letter will be ignored.
In IBM/PC mode the Greaseweazle header acts the same as on a PC motherboard: Two drives may be connected, each with an independent motor-enable line. All PC drives are strapped for drive-select DS1 (pin 12), and a cable twist is used to differentiate between drives A and B:
- A: Drive connected via a cable with twist on pins 10-16
- B: Drive connected via a straight ribbon cable
A two-drive cable will have connector(s) before and after a twist, as shown.
Up to three drives may be connected, with drive-select lines DS0-DS1 on pins 10, 12 and 14 respectively. All drives share a common motor-select signal on pin 16. Drives are addressed by drive identifiers 0, 1, and 2.
The diagrams below summarise the use of pins 10-16 on the respective buses. Click for full-size.
- Except Greaseweazle F1 (basic Blue Pill model).