You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
miaoyinb opened this issue
Dec 20, 2024
· 0 comments
· Fixed by #29597
Labels
P: normalA defect affecting operation with a low possibility of significantly affects.T: defectAn anomaly, which is anything that deviates from expectations.
CombinerGenerator provides an option to provide multiple input meshes with corresponding positions for translation. However, the first input mesh is not translated to the first position. Instead, it is placed at the origin.
Thank Soon Kyu Lee of ANL for reporting this bug.
Steps to Reproduce
The example provided in the MG's documentation has this issue too. See Case 2 and the corresponding figure.
Impact
Cannot position the first input mesh.
[Optional] Diagnostics
No response
The text was updated successfully, but these errors were encountered:
miaoyinb
added
P: normal
A defect affecting operation with a low possibility of significantly affects.
T: defect
An anomaly, which is anything that deviates from expectations.
labels
Dec 20, 2024
P: normalA defect affecting operation with a low possibility of significantly affects.T: defectAn anomaly, which is anything that deviates from expectations.
Bug Description
CombinerGenerator
provides an option to provide multiple input meshes with correspondingpositions
for translation. However, the first input mesh is not translated to the first position. Instead, it is placed at the origin.Thank Soon Kyu Lee of ANL for reporting this bug.
Steps to Reproduce
The example provided in the MG's documentation has this issue too. See Case 2 and the corresponding figure.
Impact
Cannot position the first input mesh.
[Optional] Diagnostics
No response
The text was updated successfully, but these errors were encountered: