Notifications
You must be signed in to change notification settings - Fork 18
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Juranic/visnoprobes dirschema fix (#1366)
* Create visium-no-probes-v3.2.yaml Fix raw\/fastq\/oligo\/ to raw\/fastq\/oligo\/.* (allow all files) * Update CHANGELOG.md * Documentation: Update Visium no probes docs --------- Co-authored-by: Juan Puerto <=>
- Loading branch information
Showing
3 changed files
with
112 additions
and
1 deletion.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
|
@@ -30,7 +30,31 @@ REQUIRED - For this assay, you must also prepare and submit two additional metad | |
<br> | ||
|
||
## Directory schemas | ||
<summary><b>Version 3.1 (use this one)</b></summary> | ||
<summary><b>Version 3.2 (use this one)</b></summary> | ||
|
||
| pattern | required? | description | | ||
| --- | --- | --- | | ||
| <code>extras\/.*</code> | ✓ | Folder for general lab-specific files related to the dataset | | ||
| <code>extras\/microscope_hardware\.json</code> | ✓ | **[QA/QC]** A file generated by the micro-meta app that contains a description of the hardware components of the microscope. Email HuBMAP Consortium Help Desk <[email protected]> if help is required in generating this document. | | ||
| <code>extras\/microscope_settings\.json</code> | | **[QA/QC]** A file generated by the micro-meta app that contains a description of the settings that were used to acquire the image data. Email HuBMAP Consortium Help Desk <[email protected]> if help is required in generating this document. | | ||
| <code>raw\/.*</code> | ✓ | All raw data files for the experiment. | | ||
| <code>raw\/[^\/]+\.gpr</code> | ✓ | This is a 10X Genomics layout file that's generated by 10X and individualized for each Visium slide. This is a text file and can be generated using this 10X web form <https://support.10xgenomics.com/spatial-gene-expression/software/pipelines/latest/using/slidefile-download> along with the unique 10X Visium slide ID. | | ||
| <code>raw\/additional_panels_used\.csv</code> | | If multiple commercial probe panels were used, then the primary probe panel should be selected in the "oligo_probe_panel" metadata field. The additional panels must be included in this file. Each panel record should include:manufacturer, model/name, product code. | | ||
| <code>raw\/custom_probe_set\.csv</code> | | This file should contain any custom probes used and must be included if the metadata field "is_custom_probes_used" is "Yes". The file should minimally include:target gene id, probe seq, probe id. The contents of this file are modeled after the 10x Genomics probe set file (see <https://support.10xgenomics.com/spatial-gene-expression-ffpe/probe-sets/probe-set-file-descriptions/probe-set-file-descriptions#probe_set_csv_file>). | | ||
| <code>raw\/fastq\/.*</code> | ✓ | Raw sequencing files for the experiment | | ||
| <code>raw\/fastq\/oligo\/.*</code> | ✓ | Directory containing fastq files pertaining to oligo sequencing. | | ||
| <code>raw\/fastq\/oligo\/[^\/]+\.fastq\.gz</code> | ✓ | This is a gzip version of the fastq file. This file contains the cell barcode and unique molecular identifier (technical). | | ||
| <code>raw\/images\/.*</code> | ✓ | Directory containing raw image files. This directory should include at least one raw file. | | ||
| <code>raw\/images\/[^\/]+_tissue\.(?:tif|tiff)</code> | | Raw microscope file for the experiment. For 10X Visium CytAssist, this would be the high resolution image produced. | | ||
| <code>raw\/images\/[^\/]+_fiducial\.(?:tif|tiff)</code> | ✓ | This is the low resolution image from the 10X CytAssist instrument that includes the fiduciary markings. | | ||
| <code>raw\/images\/[^\/]+\.ndpi</code> | | Raw microscope file for the experiment | | ||
| <code>lab_processed\/.*</code> | ✓ | Experiment files that were processed by the lab generating the data. | | ||
| <code>lab_processed\/alignment\.json</code> | ✓ | JSON file for the manual tissue alignment created using Loupe browser and used as input to Space Ranger. | | ||
| <code>lab_processed\/images\/.*</code> | ✓ | Processed image files | | ||
| <code>lab_processed\/images\/[^\/]+\.ome\.tiff</code> (example: <code>lab_processed/images/HBM892.MDXS.293.ome.tiff</code>) | ✓ | OME-TIFF files (multichannel, multi-layered) produced by the microscopy experiment. If compressed, must use loss-less compression algorithm. For Visium this stitched file should only include the single capture area relevant to the current dataset. For GeoMx there will be one OME TIFF file per slide, with each slide including multiple AOIs. See the following link for the set of fields that are required in the OME TIFF file XML header. <https://docs.google.com/spreadsheets/d/1YnmdTAA0Z9MKN3OjR3Sca8pz-LNQll91wdQoRPSP6Q4/edit#gid=0> | | ||
| <code>lab_processed\/images\/[^\/]*ome-tiff\.channels\.csv</code> | ✓ | This file provides essential documentation pertaining to each channel of the accommpanying OME TIFF. The file should contain one row per OME TIFF channel. The required fields are detailed <https://docs.google.com/spreadsheets/d/1xEJSb0xn5C5fB3k62pj1CyHNybpt4-YtvUs5SUMS44o/edit#gid=0> | | ||
|
||
<summary><b>Version 3.1</b></summary> | ||
|
||
| pattern | required? | description | | ||
| --- | --- | --- | | ||
|
86 changes: 86 additions & 0 deletions
86
src/ingest_validation_tools/directory-schemas/visium-no-probes-v3.2.yaml
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,86 @@ | ||
files: | ||
- | ||
pattern: extras\/.* | ||
required: True | ||
description: Folder for general lab-specific files related to the dataset | ||
- | ||
pattern: extras\/microscope_hardware\.json | ||
required: True | ||
description: A file generated by the micro-meta app that contains a description of the hardware components of the microscope. Email HuBMAP Consortium Help Desk <[email protected]> if help is required in generating this document. | ||
is_qa_qc: True | ||
- | ||
pattern: extras\/microscope_settings\.json | ||
required: False | ||
description: A file generated by the micro-meta app that contains a description of the settings that were used to acquire the image data. Email HuBMAP Consortium Help Desk <[email protected]> if help is required in generating this document. | ||
is_qa_qc: True | ||
- | ||
pattern: raw\/.* | ||
required: True | ||
description: All raw data files for the experiment. | ||
- | ||
pattern: raw\/[^\/]+\.gpr | ||
required: True | ||
description: This is a 10X Genomics layout file that's generated by 10X and individualized for each Visium slide. This is a text file and can be generated using this 10X web form <https://support.10xgenomics.com/spatial-gene-expression/software/pipelines/latest/using/slidefile-download> along with the unique 10X Visium slide ID. | ||
is_qa_qc: False | ||
- | ||
pattern: raw\/additional_panels_used\.csv | ||
required: False | ||
description: If multiple commercial probe panels were used, then the primary probe panel should be selected in the "oligo_probe_panel" metadata field. The additional panels must be included in this file. Each panel record should include:manufacturer, model/name, product code. | ||
- | ||
pattern: raw\/custom_probe_set\.csv | ||
required: False | ||
description: This file should contain any custom probes used and must be included if the metadata field "is_custom_probes_used" is "Yes". The file should minimally include:target gene id, probe seq, probe id. The contents of this file are modeled after the 10x Genomics probe set file (see <https://support.10xgenomics.com/spatial-gene-expression-ffpe/probe-sets/probe-set-file-descriptions/probe-set-file-descriptions#probe_set_csv_file>). | ||
- | ||
pattern: raw\/fastq\/.* | ||
required: True | ||
description: Raw sequencing files for the experiment | ||
- | ||
pattern: raw\/fastq\/oligo\/.* | ||
required: True | ||
description: Directory containing fastq files pertaining to oligo sequencing. | ||
- | ||
pattern: raw\/fastq\/oligo\/[^\/]+\.fastq\.gz | ||
required: True | ||
description: This is a gzip version of the fastq file. This file contains the cell barcode and unique molecular identifier (technical). | ||
is_qa_qc: False | ||
- | ||
pattern: raw\/images\/.* | ||
required: True | ||
description: Directory containing raw image files. This directory should include at least one raw file. | ||
- | ||
pattern: raw\/images\/[^\/]+_tissue\.(?:tif|tiff) | ||
required: False | ||
description: Raw microscope file for the experiment. For 10X Visium CytAssist, this would be the high resolution image produced. | ||
is_qa_qc: False | ||
- | ||
pattern: raw\/images\/[^\/]+_fiducial\.(?:tif|tiff) | ||
required: True | ||
description: This is the low resolution image from the 10X CytAssist instrument that includes the fiduciary markings. | ||
- | ||
pattern: raw\/images\/[^\/]+\.ndpi | ||
required: False | ||
description: Raw microscope file for the experiment | ||
is_qa_qc: False | ||
- | ||
pattern: lab_processed\/.* | ||
required: True | ||
description: Experiment files that were processed by the lab generating the data. | ||
- | ||
pattern: lab_processed\/alignment\.json | ||
required: True | ||
description: JSON file for the manual tissue alignment created using Loupe browser and used as input to Space Ranger. | ||
- | ||
pattern: lab_processed\/images\/.* | ||
required: True | ||
description: Processed image files | ||
- | ||
pattern: lab_processed\/images\/[^\/]+\.ome\.tiff | ||
required: True | ||
description: OME-TIFF files (multichannel, multi-layered) produced by the microscopy experiment. If compressed, must use loss-less compression algorithm. For Visium this stitched file should only include the single capture area relevant to the current dataset. For GeoMx there will be one OME TIFF file per slide, with each slide including multiple AOIs. See the following link for the set of fields that are required in the OME TIFF file XML header. <https://docs.google.com/spreadsheets/d/1YnmdTAA0Z9MKN3OjR3Sca8pz-LNQll91wdQoRPSP6Q4/edit#gid=0> | ||
is_qa_qc: False | ||
example: lab_processed/images/HBM892.MDXS.293.ome.tiff | ||
- | ||
pattern: lab_processed\/images\/[^\/]*ome-tiff\.channels\.csv | ||
required: True | ||
description: This file provides essential documentation pertaining to each channel of the accommpanying OME TIFF. The file should contain one row per OME TIFF channel. The required fields are detailed <https://docs.google.com/spreadsheets/d/1xEJSb0xn5C5fB3k62pj1CyHNybpt4-YtvUs5SUMS44o/edit#gid=0> | ||
is_qa_qc: False |