Add description for EU Battery options to enphase_envoy (#34647)
Browse files Browse the repository at this point in the history
* Add description for EU Battery options to enphase_envoy

* Small typo fix

* tiny tweaks

---------

Co-authored-by: c0ffeeca7 <[email protected]>
  • Loading branch information
catsmanac and c0ffeeca7 authored Sep 12, 2024
1 parent d41b1ce commit 7ed9ade
Showing 1 changed file with 8 additions and 6 deletions.
14 changes: 8 additions & 6 deletions source/_integrations/enphase_envoy.markdown
Original file line number Diff line number Diff line change
Expand Up @@ -62,11 +62,11 @@ For Envoy S Metered / IQ Gateway Metered with installed and configured current t
For Enphase Ensemble systems with the Enpower/IQ System Controller and Encharge/IQ Batteries installed, additional features are available:

- Sensors for battery status and usage
- Sensors for grid status (*)
- Sensors for the state of the Enpower's four load-shedding relays (*)
- A switch allowing you to take your system on-grid and off-grid. Note that the Enpower has a slight delay built-in between receiving these commands and actually switching the system on or off grid. (*)
- A switch allowing you to enable or disable charging the Encharge/IQ batteries from the power grid. (*)
- Support for changing the battery storage mode between full backup, self-consumption, and savings mode and setting the reserve battery level for outages.
- Sensors for grid status *
- Sensors for the state of the Enpower's four load-shedding relays *
- A switch allowing you to take your system on-grid and off-grid. Note that the Enpower has a slight delay built-in between receiving these commands and actually switching the system on or off grid. *
- A switch allowing you to enable or disable charging the Encharge/IQ batteries from the power grid. **
- Support for changing the battery storage mode between full backup, self-consumption, and savings mode, and setting the reserve battery level for outages. **
- If a storage <abbr title="current transformers">CT</abbr> is installed:
- Sensors for battery storage energy charged and discharged and current active power discharge/charge
- Disabled sensors for:
Expand All @@ -78,7 +78,9 @@ For Enphase Ensemble systems with the Enpower/IQ System Controller and Encharge/
- Metering status for storage <abbr title="current transformers">CT</abbr> (aggregate and phase)
- Count of meter status flags active storage <abbr title="current transformers">CT</abbr> (aggregate and phase)

The load shedding and on/off-grid functions marked (*) are only available with the Enpower/IQ System Controller installed. In battery installations without off-grid functionality, used in many EU countries, these off-grid related sensors and switches are not available.
*: The load shedding and on/off-grid functions are only available with the Enpower/IQ System Controller installed. In battery installations without load-shedding and off-grid functionality, used in many EU countries, these sensors and switches are not available.

**: When used with Enpower/IQ System Controller, the entities to charge from the grid, battery storage mode, and reserve battery level are connected to the Enpower device with the Enpower serial number in their entity and unique IDs. When no Enpower is installed, these are connected to the Envoy itself and the Envoy serial number is used in the IDs.

In multiphase installations with batteries, in countries with phase-balancing grid meters, the battery will export to the grid on one phase the amount it lacks on another phase which pulls the amount from the grid, as if it is using the grid as a 'transport' between phases. Since the grid meter will balance the amount imported and exported on the two phases, the net result is zero. The Envoy multiphase consumption CTs, however, will report the amounts on both phases, resulting in too high export on one and too high import on the other. One may consider using the `lifetime balanced net energy consumption` which is the sum of grid import and export to eliminate this effect. This would require some templating to split these values into import and export values. Alternatively, use the `current net power consumption` or `balanced net power consumption` with a Riemann integral sum helper.