request to double check the solder tip pinout definition #8
Comments
Hi. Thank you for your mail and informations. You asked a big question,
because we've spent hours to figure out how it could be, and the actual
status is still not 1000% sure. So maybe you are right, you can be right,
yes. But according to my own measurements the conclusion was that you can
see in the project's github readme. After your e-mail may I will try to
wire up the iron to my soldering controller PCB as you say. But on the
other hand, there are lot of aftermarket tip on the market, so maybe they
can be different. I used original JBC cartridges. I learned measurement
technics at university, but shame on me, I dont know what could I do with
this situation. I will take a try at my company with the 4 wire ohm meter
and I will test the cartridge on some more precise measurement equipments.
If I have something new I will update the documents and write an update to
you. If you check the cross section of the tip, you can see, that gap
between TC and heater is quite nothing... But, if you flow the heater
current between C1 and C2 the current will pass through the TC element as
well, but IDK it is a real problem or not, but the situation is this. And
if you use C2 and C3 for heating and C1 and C3 for the TC the heater
current wont flow through the TC. My personal experience: It was a way more
harder to write a proper control code because the just switched off current
caused noise on the TC right before ADC measurement, and thanks to the high
gain of the OPA the ADC input saturated to VCC, this is why Great Scott's
solution is not 100% correct. https://youtu.be/UvH49nzpJts?t=567 open this
video and see how often measures 0 instead of the real temperatures. I
think the root cause of his station is that he let the current flow through
the TC element, and he don't let the sw to act based on faulty
measurements, so he just substitute faulty measurements with 0 and it was
easier for him. :D I think mine is more sophisticated, but I don't want to
be pompous. Let me know your opinion. Have a great day!
[image: image.png][image: image.png]
Best regards.
ntchris ***@***.***> ezt írta (időpont: 2022. szept. 10.,
Szo, 16:21):
… Dear sir, great project!!
For the 245 solder tip pinout, could you please double check that you can
measure temperature from the 245 solder tip pin 1(green) and pin2(blue)
when you have a chance ?
because I found the pinout information in your front page may not be
correct ?
Anyway, to make it easier, allow me to define the largest body/shell as 1
(green in your front page),
the middle part as 2(blue), and the smallest tail pin as 3(red).
According to my measurement, when heated with hot air gun to 40-50c,
pin1(green) and 2(blue) cannot measure temperature at all (most digital
multimeter can do it measure temp), while other pin combination can.
and I did it with two different clone tips from two different brand names
/sellers, one is Kaisi, the other is AiXun.
base on this fact, pin 1(green) and 2(blue) should be heater pin, and not
ThermalCouple pin or in serial of it at all.
On the other hand, if the front page pinout is correct, pin 1 and 2 should
have been measured 40-50C (but no it couldn't ).
There is another webpage has its independent measurement has the same
conclusion, by measuring resistance (tc has some tiny resistance cannot be
easily measured )
http://adgd.ru/2021/01/04/jbc-soldering-cartridges-pinouts/
In that case, could you have been providing 24V to the heater through the
TC ? ...
another thing, some clone handle may use random color for different pins,
so....
yet another possibility, different clone tip has different pinout ??
Thanks!
—
Reply to this email directly, view it on GitHub
<#8>, or
unsubscribe
<https://github.com/notifications/unsubscribe-auth/AJZLLZL257KGLWU7V23IEADV5SKPFANCNFSM6AAAAAAQJLKRVQ>
.
You are receiving this because you are subscribed to this thread.Message
ID: ***@***.***>
--
[image: photo]
*Földvári*
Dávid
+36309508422 | ***@***.***
[image: Social icon] <http://www.facebook.com/foldvarid93/> [image: Social
icon] <http://www.instagram.com/foldvari.david/> [image: Social icon]
<http://www.linkedin.com/in/foldvari-david/>
|
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Dear sir, great project!!
For the 245 solder tip pinout, could you please double check that you can measure temperature from the 245 solder tip pin 1(green) and pin2(blue) when you have a chance ?
because I found the pinout information in your front page may not be correct ?
Anyway, to make it easier, allow me to define the largest body/shell as 1 (green in your front page),
the middle part as 2(blue), and the smallest tail pin as 3(red).
According to my measurement, when heated with hot air gun to 40-50c, pin1(green) and 2(blue) cannot measure temperature at all (most digital multimeter can do it measure temp), while other pin combination can.
and I did it with two different clone tips from two different brand names /sellers, one is Kaisi, the other is AiXun.
base on this fact, pin 1(green) and 2(blue) should be heater pin, and not ThermalCouple pin or in serial of it at all.
On the other hand, if the front page pinout is correct, pin 1 and 2 should have been measured 40-50C (but no it couldn't ).
There is another webpage has its independent measurement has the same conclusion, by measuring resistance (tc has some tiny resistance cannot be easily measured )
http://adgd.ru/2021/01/04/jbc-soldering-cartridges-pinouts/
and scott's video has the same conclusion and picture
https://www.youtube.com/watch?v=UvH49nzpJts 3:10
In that case, could you have been providing 24V to the heater through the TC ? ...
another thing, some clone handle may use random color for different pins, so....
yet another possibility, different clone tip has different pinout ??
Thanks!