The E field is discontinuous at the port boundaries where conductors are present. In this picture the ground plane is at z=0 and the strip is at z=1000. Interpolation is inaccurate there, and even though only the end points are affected, it has a noticeable effect on accuracy.
Now, all field points outside the port bounds are ignored and linear extrapolation is used to estimate the E field on the exact port bounds.