Charge unit in espresso #3633
Comments
I guess the prefactor definition is wrong on the documentation webpage in that it should be eo**2/(4piepsilon0epsilonr). This makes it equal to lBkBT and for temperature =1 (in hoomd units), the prefactor is 2 for a sigma value of 0.35 and a Bjerrum length of 0.7 nm, which is the case for water. |
Indeed, the documentation under http://espressomd.org/html/doc/electrostatics.html is inconsistent. C should be equal to C=eo**2/(4piepsilon0epsilonr) in equation (1) and the equation before needs to be adapated (via using valencies z_i=q_i/e_0) |
Should we fix this or not? |
Yes, for clarity this should be fixed. |
Description of changes: - remove CUDA installation instructions on OSX (follow-up to #3652) - update links to dockerfiles for non-Ubuntu OSes - correct the Coulomb prefactor formula (fixes #3633) - in electrostatics scripts, replace magic values by their full expressions - document the difference between serial and parallel versions of `libhdf5-dev` (fixes #3656) - improve documentation of the script that shows the effect of MPI and `node_grid` on domain decomposition (see mailing list email "dividing simulation box using MPI" from 2020-04-20)
While going through the page on electrostatics, I realized that the prefactor should be KTlB/(eo**2) instead of kTlB as suggested by the package. Most example programs have mentioned the prefactor to be 2 and the charges to be integers. How do these charges connect to the electronic charge?