Away-Mode for BC400 with GB192i*2 #2287

Open
mehlior680 opened this issue Dec 10, 2024 · 2 comments
Open

Away-Mode for BC400 with GB192i*2 #2287

mehlior680 opened this issue Dec 10, 2024 · 2 comments

Comments

@mehlior680
Copy link

Find out by "watch".

The away mode (at home, not at home) can be added by
0x10 0x16E 0 INT8

Value 0 will be at home (00)
Value -1 will be not at home/away (FF)

Unbenannt

It would be nice, if you could add it to the code.

Many thanks!

@proddy
Copy link
Contributor

proddy commented Dec 10, 2024

thanks. Is the official name (used by Bosch/Buderus) also home? We need the shortname and longname so we can add along with the language translations

@MichaelDvP
Copy link
Contributor

See #1957
But still unclear if this is a hc specific setting with hc1: 0x16E, hc2: 0x16F, ... or global for all heating circuits.