Skip to content

Commit

Permalink
fix(mf6io): cleanup description of EVAPORATION keyword in SFE and LKE
Browse files Browse the repository at this point in the history
  • Loading branch information
emorway-usgs committed Dec 13, 2024
1 parent 5dd58cf commit 7cc8029
Show file tree
Hide file tree
Showing 2 changed files with 2 additions and 2 deletions.
2 changes: 1 addition & 1 deletion doc/mf6io/mf6ivar/dfn/gwe-lke.dfn
Original file line number Diff line number Diff line change
Expand Up @@ -415,7 +415,7 @@ in_record true
reader urword
time_series true
longname evaporation temperature
description real or character value that defines the temperature of evaporated water $(e.g., ^{\circ}C or ^{\circ}F)$ for the reach. If this temperature value is larger than the simulated temperature in the reach, then the evaporated water will be removed at the same temperature as the reach. If the Options block includes a TIMESERIESFILE entry (see the ``Time-Variable Input'' section), values can be obtained from a time series by entering the time-series name in place of a numeric value.
description use of the EVAPORATION keyword is allowed in the LKE package; however, the specified value is not currently used in LKE calculations. Instead, the latent heat of evaporation is multiplied by the simulated evaporation rate for determining the thermal energy lost from a stream reach.


block period
Expand Down
2 changes: 1 addition & 1 deletion doc/mf6io/mf6ivar/dfn/gwe-sfe.dfn
Original file line number Diff line number Diff line change
Expand Up @@ -415,7 +415,7 @@ in_record true
reader urword
time_series true
longname evaporation temperature
description real or character value that defines the temperature of evaporated water $(e.g., ^{\circ}C or ^{\circ}F)$ for the reach. If this temperature value is larger than the simulated temperature in the reach, then the evaporated water will be removed at the same temperature as the reach. If the Options block includes a TIMESERIESFILE entry (see the ``Time-Variable Input'' section), values can be obtained from a time series by entering the time-series name in place of a numeric value.
description use of the EVAPORATION keyword is allowed in the SFE package; however, the specified value is not currently used in SFE calculations. Instead, the latent heat of evaporation is multiplied by the simulated evaporation rate for determining the thermal energy lost from a stream reach.

block period
name runoff
Expand Down

0 comments on commit 7cc8029

Please sign in to comment.