I2S clock for mcHF STM32F4 corrected to 12.288Mhz #1464
Merged
+46
−49
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Found working clock configuration which provides exactly 12.288 Mhz as I2S
clock and not something slightly lower as before. This may reduce USB audio
issues but still depends on accurate clocks on BOTH ends of the USB
connection (which is never a 100% match). However, for most mcHF USB audio
user this should improve audio quality. No impact on OVI40 which already
uses the correct 12.288Mhz clock. See discussion on #1077
BTW: The previous "official" difference was about 0.01% or 100ppm.