A new Pull Request was created by @DryRun (David Yu) for CMSSW_10_6_X. It involves the following packages: DQM/HcalCommon @andrius-k, @kmaeshima, @schneiml, @cmsbuild, @jfernan2, @fioriNTU can you please review it and eventually sign? Thanks. cms-bot commands are listed here |
Pull request #27881 was updated. @andrius-k, @kmaeshima, @schneiml, @cmsbuild, @jfernan2, @fioriNTU can you please check and sign again. |
please test |
The tests are being triggered in jenkins. |
Comparison job queued. |
Comparison is ready Comparison Summary:
|
+1 |
This pull request is fully signed and it will be integrated in one of the next CMSSW_10_6_X IBs (tests are also fine) and once validation in the development release cycle CMSSW_11_0_X is complete. This pull request will now be reviewed by the release team before it's merged. @davidlange6, @slava77, @smuzaffar, @fabiocos (and backports should be raised in the release meeting by the corresponding L2) |
+1 |
PR description:
Fixes the plotting of HB TDC, which has only 2 bits, not 6 bits as in HE/HF.
PR validation:
Passes runTheMatrix test on Run 3 workflows. Correctly plots HB TDC for MWGR3 data.
if this PR is a backport please specify the original PR:
#27880