Stop charging if ambient temp is outside battery specification. #41

Closed
tobbeanton opened this issue Jan 17, 2020 · 2 comments
Closed

Stop charging if ambient temp is outside battery specification. #41

tobbeanton opened this issue Jan 17, 2020 · 2 comments
Milestone

Comments

@tobbeanton
Copy link
Member

No description provided.

@tobbeanton
Copy link
Member Author

Closed by 2eea7cb.

@tobbeanton tobbeanton changed the title Stop charging of ambient temp is outside battery specification. Stop charging if ambient temp is outside battery specification. Jan 17, 2020
@tobbeanton tobbeanton added this to the 2020.02 milestone Feb 4, 2020
@tobbeanton
Copy link
Member Author

tobbeanton commented Feb 4, 2020

Implementation is using the nRF51 internal temp sensor and the interval is set to charge if this temp is between 15-60 degrees, that equals ruffly 5-45 degrees ambient temp as the electronics heat up the sensor.

This implementation might cause confusion for the user if the battery suddenly stop charging. Currently it is shown by that the blue M2 led will turn off and the blue M3 light will stop blinking.