You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
tobbeanton
changed the title
Stop charging of ambient temp is outside battery specification.
Stop charging if ambient temp is outside battery specification.
Jan 17, 2020
Implementation is using the nRF51 internal temp sensor and the interval is set to charge if this temp is between 15-60 degrees, that equals ruffly 5-45 degrees ambient temp as the electronics heat up the sensor.
This implementation might cause confusion for the user if the battery suddenly stop charging. Currently it is shown by that the blue M2 led will turn off and the blue M3 light will stop blinking.
No description provided.
The text was updated successfully, but these errors were encountered: