[SDIS 71]: Met en place la méthode calcul_debit_pression_71()
Browse files Browse the repository at this point in the history
Issue: #207189
Change-Id: I65e8027efb5e462e5ef58cc1ce9c4868918d4dfa
  • Loading branch information
Clément GRENOT authored and Emilie Genton committed May 3, 2024
1 parent b2bb761 commit d91bca2
Showing 1 changed file with 195 additions and 0 deletions.
Original file line number Diff line number Diff line change
@@ -0,0 +1,195 @@
------ Désactivation des triggers
ALTER TABLE remocra.hydrant_anomalies DISABLE TRIGGER trig_aui;
ALTER TABLE remocra.hydrant_anomalies DISABLE TRIGGER trig_bd;
ALTER TABLE remocra.hydrant_anomalies DISABLE TRIGGER trig_indispo;
ALTER TABLE remocra.hydrant_pibi DISABLE TRIGGER trig_aui;
ALTER TABLE remocra.hydrant_pibi DISABLE TRIGGER trig_debit_pression;
ALTER TABLE remocra.hydrant DISABLE TRIGGER trg_hydrant_u;
ALTER TABLE remocra.hydrant DISABLE TRIGGER trig_aui;
ALTER TABLE remocra.hydrant DISABLE TRIGGER trig_date_changement_dispo_terrestre;
ALTER TABLE remocra.hydrant DISABLE TRIGGER trig_hydrant_couverture;

-- Correctifs avant la mise en place de la méthode:
---- Nullifier les debit_max
UPDATE remocra.hydrant_pibi SET debit_max = NULL WHERE debit_max IS NOT NULL;
---- Nullifier les pression_dyn_deb
UPDATE remocra.hydrant_pibi SET pression_dyn_deb = NULL WHERE pression_dyn_deb IS NOT NULL;

---- Mise a plat des anomalies systèmes
------ Suppression de l'assignation de l'anomalie aux PEI
Delete from remocra.hydrant_anomalies where anomalies in (
select id from remocra.type_hydrant_anomalie
where critere IS NULL
AND code <> 'INDISPONIBILITE_TEMP');
------ Suppression des indices fonctionnels
DELETE FROM remocra.type_hydrant_anomalie_nature WHERE anomalie IN (
select id from remocra.type_hydrant_anomalie
where critere IS NULL
AND code <> 'INDISPONIBILITE_TEMP');
------ Suppression des anomalies
DELETE FROM remocra.type_hydrant_anomalie
where critere IS NULL
AND code <> 'INDISPONIBILITE_TEMP';
------ Insertion des anomalies
INSERT INTO remocra.type_hydrant_anomalie (actif, code, commentaire, nom, "version", critere)
VALUES
(true, 'DEBIT_INSUFF','Anomalie système, ne pas modifier','Débit insuffisant',1,null),
(true, 'DEBIT_INSUFF_NC','Anomalie système, ne pas modifier','Débit insuffisant (non conforme)',1,null),
(true, 'DEBIT_TROP_ELEVE','Anomalie système, ne pas modifier','Débit trop élevé',1,null),
(true, 'DEBIT_TROP_ELEVE_NC','Anomalie système, ne pas modifier','Débit trop élevé (non conforme)',1,null),
(true, 'PRESSION_DYN_INSUFF','Anomalie système, ne pas modifier','Pression dynamique insuffisante',1,null),
(true, 'PRESSION_DYN_INSUFF_NC','Anomalie système, ne pas modifier','Pression dynamique insuffisante (non conforme)',1,null),
(true, 'PRESSION_DYN_TROP_ELEVEE','Anomalie système, ne pas modifier','Pression dynamique trop élevée',1,null),
(true, 'PRESSION_DYN_TROP_ELEVEE_NC','Anomalie système, ne pas modifier','Pression dynamique trop élevée (non conforme)',1,null),
(true, 'PRESSION_INSUFF','Anomalie système, ne pas modifier','Pression statique insuffisante',1,null),
(true, 'PRESSION_INSUFF_NC','Anomalie système, ne pas modifier','Pression statique insuffisante (non conforme)',1,null),
(true, 'PRESSION_TROP_ELEVEE','Anomalie système, ne pas modifier','Pression statique trop élevée',1,null),
(true, 'PRESSION_TROP_ELEVEE_NC','Anomalie système, ne pas modifier','Pression statique trop élevée (non conforme)',1,null);
------ Insertion des indices fonctionnels (toutes les anomalies système)
WITH value_to_insert AS (
SELECT
5 AS val_indispo_terrestre,
tha.id AS anomalie,
thn.id AS nature
FROM remocra.type_hydrant_anomalie tha
JOIN remocra.TYPE_hydrant_nature thn ON (thn.code = 'PI' or thn.code = 'BI' or thn.code = 'PA')
WHERE critere IS NULL
)
INSERT INTO remocra.type_hydrant_anomalie_nature (val_indispo_terrestre, anomalie, nature)
SELECT * FROM value_to_insert;
------ Update des indices fonctionnels (anomalies non conforme)
UPDATE remocra.type_hydrant_anomalie_nature
SET val_indispo_terrestre = 0
WHERE anomalie IN (
SELECT id
FROM remocra.type_hydrant_anomalie
WHERE code LIKE '%_NC'
AND critere is null
);
------ Ré-activation des triggers
ALTER TABLE remocra.hydrant_anomalies ENABLE TRIGGER trig_aui;
ALTER TABLE remocra.hydrant_anomalies ENABLE TRIGGER trig_bd;
ALTER TABLE remocra.hydrant_anomalies ENABLE TRIGGER trig_indispo;
ALTER TABLE remocra.hydrant_pibi ENABLE TRIGGER trig_aui;
ALTER TABLE remocra.hydrant ENABLE TRIGGER trg_hydrant_u;
ALTER TABLE remocra.hydrant ENABLE TRIGGER trig_aui;
ALTER TABLE remocra.hydrant ENABLE TRIGGER trig_date_changement_dispo_terrestre;
ALTER TABLE remocra.hydrant ENABLE TRIGGER trig_hydrant_couverture;


-- Création fonction spécifique calcul_debit_pression_71
create or replace function remocra.calcul_debit_pression_71(id_hydrant bigint)
returns void
language plpgsql
AS $function$
DECLARE
p_anomalie_id INTEGER;
P_rec remocra.hydrant_pibi % rowtype;
p_code_type_hydrant_nature VARCHAR;
BEGIN
select * into p_rec from remocra.hydrant_pibi where id = id_hydrant;
-- Suppression des anciennes anomalies
delete from remocra.hydrant_anomalies where hydrant = p_rec.id and anomalies in (
select id
from remocra.type_hydrant_anomalie
where critere IS NULL
AND code <> 'INDISPONIBILITE_TEMP');
-- Récupération du type_hydrant_nature id
select thn.code into p_code_type_hydrant_nature from remocra.hydrant h left join remocra.type_hydrant_nature thn on (thn.id=h.nature) where h.id = id_hydrant;
-- Aucune mise en indisponibilité automatique, simplement indiquer que le PIBI est non conforme.
-- mise en non conformité uniquement dans le cas d'un-e débit/pression insuffisant-e.
IF FOUND THEN
-- Pression dynamique
-- Pression dynamique insuffisante
IF(p_rec.pression_dyn < 1) THEN
SELECT id INTO p_anomalie_id FROM remocra.type_hydrant_anomalie WHERE code = 'PRESSION_DYN_INSUFF';
INSERT INTO remocra.hydrant_anomalies (hydrant,anomalies) VALUES (p_rec.id,p_anomalie_id);
END IF;
-- Pression dynamique insuffisante non conforme
IF(p_rec.pression_dyn >= 1 AND p_rec.pression_dyn < 2) THEN
SELECT id INTO p_anomalie_id FROM remocra.type_hydrant_anomalie WHERE code = 'PRESSION_DYN_INSUFF_NC';
INSERT INTO remocra.hydrant_anomalies (hydrant,anomalies) VALUES (p_rec.id,p_anomalie_id);
END IF;
-- Pression dynamique trop élevée non conforme
IF(p_rec.pression_dyn >= 10 AND p_rec.pression_dyn <= 16) THEN
SELECT id INTO p_anomalie_id FROM remocra.type_hydrant_anomalie WHERE code = 'PRESSION_DYN_TROP_ELEVEE_NC';
INSERT INTO remocra.hydrant_anomalies (hydrant,anomalies) VALUES (p_rec.id,p_anomalie_id);
END IF;
-- Pression dynamique trop élevée
IF(p_rec.pression_dyn > 16) then
SELECT id INTO p_anomalie_id FROM remocra.type_hydrant_anomalie WHERE code = 'PRESSION_DYN_TROP_ELEVEE';
INSERT INTO remocra.hydrant_anomalies (hydrant,anomalies) VALUES (p_rec.id,p_anomalie_id);
end if;

-- Débit
-- Diamètre 80
IF (p_rec.diametre = (SELECT id FROM remocra.type_hydrant_diametre WHERE code ILIKE 'DIAM80')) then
if (p_rec.debit < 30) then
SELECT id INTO p_anomalie_id FROM remocra.type_hydrant_anomalie WHERE code = 'DEBIT_INSUFF';
INSERT INTO remocra.hydrant_anomalies (hydrant,anomalies) VALUES (p_rec.id,p_anomalie_id);
END IF;
END IF;
-- Diamètre 100
IF (p_rec.diametre = (SELECT id FROM remocra.type_hydrant_diametre WHERE code ILIKE 'DIAM100')
OR p_rec.diametre IS NULL) then
-- Débit insuffisant
if (p_rec.debit < 30) then
SELECT id INTO p_anomalie_id FROM remocra.type_hydrant_anomalie WHERE code = 'DEBIT_INSUFF';
INSERT INTO remocra.hydrant_anomalies (hydrant,anomalies) VALUES (p_rec.id,p_anomalie_id);
END IF;
-- Débit insuffisant non-conforme
if (p_rec.debit >= 30 and p_rec.debit < 60) then
SELECT id INTO p_anomalie_id FROM remocra.type_hydrant_anomalie WHERE code = 'DEBIT_INSUFF_NC';
INSERT INTO remocra.hydrant_anomalies (hydrant,anomalies) VALUES (p_rec.id,p_anomalie_id);
END IF;
END IF;
-- Diamètre 150
IF (p_rec.diametre = (SELECT id FROM remocra.type_hydrant_diametre WHERE code ILIKE 'DIAM150')) then
-- Débit insuffisant
if (p_rec.debit < 60) then
SELECT id INTO p_anomalie_id FROM remocra.type_hydrant_anomalie WHERE code = 'DEBIT_INSUFF';
INSERT INTO remocra.hydrant_anomalies (hydrant,anomalies) VALUES (p_rec.id,p_anomalie_id);
END IF;
-- Débit insuffisant non-conforme
if (p_rec.debit >= 60 and p_rec.debit < 120) then
SELECT id INTO p_anomalie_id FROM remocra.type_hydrant_anomalie WHERE code = 'DEBIT_INSUFF_NC';
INSERT INTO remocra.hydrant_anomalies (hydrant,anomalies) VALUES (p_rec.id,p_anomalie_id);
END IF;
END IF;
end if;
end;
$function$;

-- @@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@
-- @@ Gestion des appels de fonctions @@
-- @@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@
---- Ajout fonction appel calul_debit_pression_71
Create or replace function remocra.trg_calcul_debit_pression_71()
returns TRIGGER
language plpgsql
as $function$
declare p_rec RECORD;
BEGIN
if (TG_OP = 'DELETE') then
p_rec = OLD;
else
p_rec = NEW;
end if;
perform remocra.calcul_debit_pression_71(p_rec.id);
RETURN p_rec;
END;
$function$;

---- Ajout Trigger calcul_debit_pression_71 à la table hydrant_pibi
DROP TRIGGER IF EXISTS trig_debit_pression_71 ON remocra.hydrant_pibi;
CREATE TRIGGER trig_debit_pression_71
AFTER INSERT OR UPDATE ON remocra.hydrant_pibi
FOR EACH ROW
EXECUTE PROCEDURE remocra.trg_calcul_debit_pression_71();
---- Désactivation du trigger de calcul_debit_pression initial
ALTER TABLE remocra.hydrant_pibi DISABLE TRIGGER trig_debit_pression;
-- @@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@
-- @@ Remise en état des anomalies avec la nouvelle regle de calcul @@
-- @@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@
SELECT remocra.calcul_debit_pression_71(id) FROM remocra.hydrant_pibi;
ALTER TABLE remocra.hydrant_pibi ENABLE TRIGGER trig_debit_pression;