Skip to content

Commit

Permalink
Add blower bc function (#3872)
Browse files Browse the repository at this point in the history
* Add recirculation boundary create and edit

* add assign_recirculation_opening

* add recirculation test

* update name in example

* add dictionary support

* improve input arguments handling

* add dictionary test

* add "blower" in create and update functions

* add functions to create blower

* add blower tests

* [pre-commit.ci] auto fixes from pre-commit.com hooks

for more information, see https://pre-commit.ci

* add pragma nocover

* update docstring

* fix indentation

* add no cover to GrpcApiError

* Update pyaedt/icepak.py

* Update pyaedt/icepak.py

---------

Co-authored-by: pre-commit-ci[bot] <66853113+pre-commit-ci[bot]@users.noreply.github.com>
Co-authored-by: Samuel Lopez <[email protected]>
  • Loading branch information
3 people authored Nov 14, 2023
1 parent 55bbb97 commit ddcc3d7
Show file tree
Hide file tree
Showing 3 changed files with 203 additions and 26 deletions.
13 changes: 13 additions & 0 deletions _unittest/test_98_Icepak.py
Original file line number Diff line number Diff line change
Expand Up @@ -1337,3 +1337,16 @@ def test_69_recirculation_boundary(self):
thermal_specification="Temperature",
flow_assignment=flow_dict,
)

def test_70_blower_boundary(self):
cylinder = self.aedtapp.modeler.create_cylinder(cs_axis="X", position=[0, 0, 0], radius=10, height=1)
curved_face = [f for f in cylinder.faces if not f.is_planar]
planar_faces = [f for f in cylinder.faces if f.is_planar]
assert not self.aedtapp.assign_blower_type1(curved_face + planar_faces, planar_faces, [10, 5, 0], [0, 1, 2, 4])
blower = self.aedtapp.assign_blower_type1(
[f.id for f in curved_face + planar_faces], [f.id for f in planar_faces], [10, 5, 0], [0, 2, 4]
)
assert blower
assert blower.update()
box = self.aedtapp.modeler.create_box([5, 5, 5], [1, 2, 3], "BlockBoxEmpty", "copper")
assert self.aedtapp.assign_blower_type2([box.faces[0], box.faces[1]], [box.faces[0]], [10, 5, 0], [0, 2, 4])
212 changes: 186 additions & 26 deletions pyaedt/icepak.py
Original file line number Diff line number Diff line change
Expand Up @@ -4880,44 +4880,45 @@ def assign_recirculation_opening(self, face_list, extract_face, thermal_specific
Parameters
----------
face_list : list
List of modeler.cad.elements3d.FacePrimitive or of integers
containing faces ids.
List of face primitive objects or a list of integers
containing faces IDs.
extract_face : modeler.cad.elements3d.FacePrimitive, int
Face of the face on the extract side.
ID of the face on the extract side.
thermal_specification : str, optional
Type of the thermal assignment across the two recirculation
faces. Options are ``"Conductance"``, ``"Heat Input"`` and
``"Temperature"``. Default is ``"Temperature"``.
faces. The default is ``"Temperature"``. Options are
``"Conductance"``, ``"Heat Input"``, and ``"Temperature"``.
assignment_value : str or dict, optional
String with value and units of the thermal assignment. For a
transient assignment, a dictionary can be used. The dictionary
should contain two keys: ``"Function"`` and ``"Values"``.
- For the ``"Function"`` key, acceptable values are
- For the ``"Function"`` key, options are
``"Exponential"``, ``"Linear"``, ``"Piecewise Linear"``,
``"Power Law"``, ``"Sinusoidal"``, and ``"Square Wave"``.
- For the ``"Values"`` key, a list of strings containing the
- For the ``"Values"`` key, provide a list of strings containing the
parameters required by the ``"Function"`` key selection. For
example, when``"Linear"`` is set as the ``"Function"`` key, two
example, when ``"Linear"`` is set as the ``"Function"`` key, two
parameters are required: the value of the variable at t=0 and the
slope of the line. For the parameters required by each
``"Function"`` key selection, see the Icepak documentation.
slope of the line. For the parameters required by each ``"Function"``
key selection, see the Icepak documentation.
The parameters must contain the units where needed.
The default value is ``"0cel"``.
conductance_external_temperature : str, optional
External temperature value, needed if ``thermal_specification``
is set to ``"Conductance"``. Default is ``None``.
External temperature value, which is needed if
``thermal_specification`` is set to ``"Conductance"``.
The default is ``None``.
flow_specification : str, optional
Flow specification for the recirculation zone. Available
options are: ``"Mass Flow"``, ``"Mass Flux"``, and
``"Volume Flow"``. The default value is ``"Mass Flow"``.
Flow specification for the recirculation zone. The default is
``"Mass Flow"``. Options are: ``"Mass Flow"``, ``"Mass Flux"``,
and ``"Volume Flow"``.
flow_assignment : str or dict, optional
String with value and units of the flow assignment. For a
String with the value and units of the flow assignment. For a
transient assignment, a dictionary can be used. The dictionary
should contain two keys: ``"Function"`` and ``"Values"``.
- For the ``"Function"`` key, acceptable values are
- For the ``"Function"`` key, options are
``"Exponential"``, ``"Linear"``, ``"Piecewise Linear"``,
``"Power Law"``, ``"Sinusoidal"``, and ``"Square Wave"``.
- For the ``"Values"`` key, a list of strings containing the
- For the ``"Values"`` key, provide a list of strings containing the
parameters required by the ``"Function"`` key selection. For
example, when``"Linear"`` is set as the ``"Function"`` key, two
parameters are required: the value of the variable at t=0 and the
Expand All @@ -4927,13 +4928,13 @@ def assign_recirculation_opening(self, face_list, extract_face, thermal_specific
The default value is ``"0kg_per_s_m2"``.
flow_direction : list, optional
Flow direction enforced at the recirculation zone. The default value
is ``None`` in which case the normal direction is used.
is ``None``, in which case the normal direction is used.
start_time : str, optional
Start of the time interval. Relevant only if the simulation is
transient. The default value is ``"0s"``.
Start of the time interval. This parameter is relevant only if the
simulation is transient. The default value is ``"0s"``.
end_time : str, optional
End of the time interval. Relevant only if the simulation is
transient. The default value is ``"0s"``.
End of the time interval. This parameter is relevant only if the
simulation is transient. The default value is ``"0s"``.
boundary_name : str, optional
Name of the recirculation boundary. The default is ``None``, in
which case the boundary is automatically generated.
Expand Down Expand Up @@ -4964,15 +4965,15 @@ def assign_recirculation_opening(self, face_list, extract_face, thermal_specific
return False
if conductance_external_temperature is not None and thermal_specification is not "Conductance":
self.logger.warning(
'``conductance_external_temperature`` will not have any effect unless the ``thermal_specification`` '
'``conductance_external_temperature`` does not have any effect unless the ``thermal_specification`` '
'is ``"Conductance"``.')
if conductance_external_temperature is not None and thermal_specification is not "Conductance":
self.logger.warning(
'``conductance_external_temperature`` needs to be specified when ``thermal_specification`` '
'``conductance_external_temperature`` must be specified when ``thermal_specification`` '
'is ``"Conductance"``. Setting ``conductance_external_temperature`` to ``"AmbientTemp"``.')
if (start_time is not None or end_time is not None) and not self.solution_type == "Transient":
self.logger.warning(
'``start_time`` and ``end_time`` will not have any effect unless for steady-state simulations.')
'``start_time`` and ``end_time`` only effect steady-state simulations.')
elif self.solution_type == "Transient" and not (start_time and end_time):
self.logger.warning(
'``start_time`` and ``end_time`` should be declared for transient simulations. Setting them to "0s".')
Expand Down Expand Up @@ -5046,5 +5047,164 @@ def assign_recirculation_opening(self, face_list, extract_face, thermal_specific
return bound
else: # pragma: no cover
raise SystemExit
except (GrpcApiError, SystemExit): # pragma : no cover
return None

@pyaedt_function_handler()
def assign_blower_type1(self, faces, inlet_face, fan_curve_pressure, fan_curve_flow, blower_power="0W", blade_rpm=0,
blade_angle="0rad", fan_curve_pressure_unit="n_per_meter_sq",
fan_curve_flow_unit="m3_per_s", boundary_name=None):
"""Assign blower type 1.
Parameters
----------
faces : list
List of modeler.cad.elements3d.FacePrimitive or of integers
containing faces ids.
inlet_face : modeler.cad.elements3d.FacePrimitive, int or list
Inlet faces.
fan_curve_pressure : list
List of the fan curve pressure values. Only floats should
be included in the list as their unit can be modified with
fan_curve_pressure_unit argument.
fan_curve_flow : list
List of the fan curve flow value. Only floats should be
included in the list as their unit can be modified with
fan_curve_flow_unit argument.
blower_power : str, optional
blower power expressed as a string containing the value and unit.
Default is "0W".
blade_rpm : float, optional
Blade RPM value. Default is 0.
blade_angle : str, optional
Blade angle expressed as a string containing value and the unit.
Default is "0rad".
fan_curve_pressure_unit : str, optional
Fan curve pressure unit. Default is "n_per_meter_sq".
fan_curve_flow_unit : str, optional
Fan curve flow unit. Default is "m3_per_s".
boundary_name : str, optional
Name of the recirculation boundary. The default is ``None``, in
which case the boundary is automatically generated.
Returns
-------
:class:`pyaedt.modules.Boundary.BoundaryObject`
Boundary object when successful or ``None`` when failed.
References
----------
>>> oModule.AssignBlowerBoundary
Examples
--------
>>> from pyaedt import Icepak
>>> ipk = Icepak()
>>> cylinder = self.aedtapp.modeler.create_cylinder(cs_axis="X", position=[0,0,0], radius=10, height=1)
>>> curved_face = [f for f in cylinder.faces if not f.is_planar]
>>> planar_faces = [f for f in cylinder.faces if f.is_planar]
>>> cylinder.solve_inside=False
>>> blower = self.aedtapp.assign_blower_type1([f.id for f in curved_face+planar_faces],
>>> [f.id for f in planar_faces], [10, 5, 0], [0, 2, 4])
"""
props = {}
props["Blade RPM"] = blade_rpm
props["Fan Blade Angle"] = blade_angle
props["Blower Type"] = "Type 1"
return self._assign_blower(props, faces, inlet_face, fan_curve_flow_unit, fan_curve_pressure_unit,
fan_curve_flow, fan_curve_pressure, blower_power, boundary_name)

@pyaedt_function_handler()
def assign_blower_type2(self, faces, inlet_face, fan_curve_pressure, fan_curve_flow, blower_power="0W",
exhaust_angle="0rad", fan_curve_pressure_unit="n_per_meter_sq",
fan_curve_flow_unit="m3_per_s", boundary_name=None):
"""Assign blower type 2.
Parameters
----------
faces : list
List of modeler.cad.elements3d.FacePrimitive or of integers
containing faces ids.
inlet_face : modeler.cad.elements3d.FacePrimitive, int or list
Inlet faces.
fan_curve_pressure : list
List of the fan curve pressure values. Only floats should
be included in the list as their unit can be modified with
fan_curve_pressure_unit argument.
fan_curve_flow : list
List of the fan curve flow value. Only floats should be
included in the list as their unit can be modified with
fan_curve_flow_unit argument.
blower_power : str, optional
blower power expressed as a string containing the value and unit.
Default is "0W".
exhaust_angle : float, optional
Exhaust angle expressed as a string containing value and the unit.
Default is "0rad".
fan_curve_pressure_unit : str, optional
Fan curve pressure unit. Default is "n_per_meter_sq".
fan_curve_flow_unit : str, optional
Fan curve flow unit. Default is "m3_per_s".
boundary_name : str, optional
Name of the recirculation boundary. The default is ``None``, in
which case the boundary is automatically generated.
Returns
-------
:class:`pyaedt.modules.Boundary.BoundaryObject`
Boundary object when successful or ``None`` when failed.
References
----------
>>> oModule.AssignBlowerBoundary
Examples
--------
>>> from pyaedt import Icepak
>>> ipk = Icepak()
>>> box = ipk.modeler.create_box([5, 5, 5], [1, 2, 3], "BlockBoxEmpty", "copper")
>>> box.solve_inside=False
>>> blower = self.aedtapp.assign_blower_type2([box.faces[0], box.faces[1]],
>>> [box.faces[0]], [10, 5, 0], [0, 2, 4])
"""
props = {}
props["Exhaust Exit Angle"] = exhaust_angle
props["Blower Type"] = "Type 2"
return self._assign_blower(props, faces, inlet_face, fan_curve_flow_unit, fan_curve_pressure_unit,
fan_curve_flow, fan_curve_pressure, blower_power, boundary_name)

@pyaedt_function_handler()
def _assign_blower(self, props, faces, inlet_face, fan_curve_flow_unit, fan_curve_pressure_unit, fan_curve_flow,
fan_curve_pressure, blower_power, boundary_name):
if isinstance(faces[0], int):
props["Faces"] = faces
else:
props["Faces"] = [f.id for f in faces]
if not isinstance(inlet_face, list):
inlet_face = [inlet_face]
if not isinstance(inlet_face[0], int):
props["InletFace"] = [f.id for f in inlet_face]
props["Blower Power"] = blower_power
props["DimUnits"] = [fan_curve_flow_unit, fan_curve_pressure_unit]
if len(fan_curve_flow) != len(fan_curve_pressure):
self.logger.error("``fan_curve_flow`` and ``fan_curve_pressure`` must have the same length.")
return False
props["X"] = [str(pt) for pt in fan_curve_flow]
props["Y"] = [str(pt) for pt in fan_curve_pressure]
if not boundary_name:
boundary_name = generate_unique_name("Blower")
bound = BoundaryObject(self, boundary_name, props, "Blower")
try:
if bound.create():
self._boundaries[bound.name] = bound
return bound
else: # pragma : no cover
raise SystemExit
except (GrpcApiError, SystemExit): # pragma: no cover
return None
4 changes: 4 additions & 0 deletions pyaedt/modules/Boundary.py
Original file line number Diff line number Diff line change
Expand Up @@ -570,6 +570,8 @@ def create(self):
self._app.oboundary.AssignGrilleBoundary(self._get_args())
elif bound_type == "Block":
self._app.oboundary.AssignBlockBoundary(self._get_args())
elif bound_type == "Blower":
self._app.oboundary.AssignBlowerBoundary(self._get_args())
elif bound_type == "SourceIcepak":
self._app.oboundary.AssignSourceBoundary(self._get_args())
elif bound_type == "Opening":
Expand Down Expand Up @@ -748,6 +750,8 @@ def update(self):
self._app.oboundary.EditEMLoss(self._boundary_name, self._get_args()) # pragma: no cover
elif bound_type == "Block":
self._app.oboundary.EditBlockBoundary(self._boundary_name, self._get_args())
elif bound_type == "Blower":
self._app.oboundary.EditBlowerBoundary(self._boundary_name, self._get_args())
elif bound_type == "SourceIcepak":
self._app.oboundary.EditSourceBoundary(self._boundary_name, self._get_args())
elif bound_type == "HeatFlux":
Expand Down