The NWA OBC experiments suffer from a restart issue. There are a few bugs mixed together that were causing these and this update tries to address them. There were two basic issues; 1. A few missing halo updates causing the physical as well as obgc experiments not to reproduce
2. Bad logic for determining the update time for obgc tracers that use a segment updating period larger than DT.
Here's how to address these:
fixes the restart issue for the physical model T&S
fixes the restart issue for the BGC tracers when segment update period = DT
fixes the logic for setting the update time (it was not correct)
Note that DT_OBC_SEG_UPDATE_OBGC has to be an integer multiple of DT and DT_THERM !