Skip to content

Multi-device control console application. Plug-n-Play design for serial RS232 and I2C connection. Considered device types: multimeters, HV sources, motion controller, environmental readings

License

Notifications You must be signed in to change notification settings

TomasKello/mkMeasure

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

46 Commits
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

mkMeasure

Multi-device control console application. Plug-n-Play design for serial RS232 and I2C connection. Considered device types:

  • multimeters
  • HV sources
  • motion controller
  • environmental readings

Get repository:

git clone https://github.com/TomasKello/mkMeasure.git

Install:

cd mkMeasure/install
(Install pre-requisites in requirements.txt)
chmod u+rwx setup.sh
./setup.sh

Re-compile if needed:

cd mkMeasure/install
chmod u+rwx update.sh
./update.sh

Quick start:

mkMeasure --addPort zstation,probeFast -vvv --txt --json --csv --png --expOhm 1e7 -d FMX -o FMX_Sandwich_Bottom_Number --cfg IV_5-800step20.py

  • --cfg defines path to configuration file (default search dir is configuration/IV_5-800step20.py)
  • options -d and -o define path to output directory and nametag: results/FMX/FMX_Sandwich_Bottom_Number_YYYYMMDD.<format>
  • options --txt/json/csv/png define output
  • --addPort enlists device types communicating through RS232 protocol needed per measurement defined in config (zstation, probeFast, probe, source)
  • --expOhm defines ballpark of operational "resistance" (in Ohms) to set correct resolution. Option is used instead of --autoRange to speed up measurement.
  • -vvv defines 3rd level of verbosity (debug)

mkMeasure --addPort probe -vvv -e all

  • read enviro input only

mkMeasure --term mkMeasure --abort

  • mkMeasure has autonomous abort system
  • these options serve only to manually terminate (soft) or abort (hard) all devices after unresolved emergency or unpredicted program crash

All options:

usage: mkMeasure [-h] [--testPort | --testMeas | --testStatus] [--selectPort]
                 [--extVSource] [--addPort ADDPORT] [--addSocket ADDSOCKET]
                 [--expOhm expected_resistance] [--autoSensing] [--autoRange]
                 [-v] [-o OUTPUTFILE] [-d OUTPUTDIR] [--txt] [--json] [--csv]
                 [--xml] [--root] [--png] [--pdf] [--db]
                 [--cfg CONFIGFILE | -s <bias> | -m <bias_range> | -c <bias_range> | -e <enviro> | -g <cont_enviro> | -w <stand_by_mode>]
                 [-r <repeat>] [--sampleTime <sample_time>]
                 [--nSamples <n_samples>] [--debug] [--term | --abort]

optional arguments:
  -h, --help            show this help message and exit
  --testPort            Find available ports and exit measurement.
  --testMeas            Try single IV measurement with +-10V.
  --testStatus          Show device status.
  --selectPort          Disable automatic port selection.
  --extVSource          Use the secondary device as a VSource.
  --addPort ADDPORT     Enable additional port to be used as RS232.
  --addSocket ADDSOCKET
                        Enable additional port to be used as Client.
  --expOhm expected_resistance
                        Expected resistance order.
  --autoSensing         Enable automatic current sensing when placing probe.
  --autoRange           Enable automatic autorange for measured function.
  -v, --verbosity       Increase output verbosity
  -o OUTPUTFILE, --outputFile OUTPUTFILE
                        Output file name.
  -d OUTPUTDIR, --outputDir OUTPUTDIR
                        Output directory.
  --txt                 Produce output in txt format.
  --json                Produce output in json format.
  --csv                 Produce output in csv format.
  --xml                 Produce output in xml format.
  --root                Produce output in root format.
  --png                 Produce output in png format.
  --pdf                 Produce output in pdf format.
  --db                  Input/Outpur are taken/saved in DB.
  --cfg CONFIGFILE      Define measurement inside of config file.
  -s <bias>, --single <bias>
                        Single IV measurement. USAGE: -s 60.5
  -m <bias_range>, --multi <bias_range>
                        Multiple point IV measurement. USAGE: -m start end
                        incr OR -c [1,2,3,4]
  -c <bias_range>, --continuous <bias_range>
                        Continuous IV measurement. USAGE: -c start end incr OR
                        -c [1,2,3,4]
  -e <enviro>, --enviro <enviro>
                        Enviro readings: all, temp, humi or lumi.
  -g <cont_enviro>, --contenv <cont_enviro>
                        Continuous Enviro measurement. USAGE: -g <type>
                        [<timeStep> <nSteps>]
  -w <stand_by_mode>, --standBy <stand_by_mode>
                        Stanby mode with motion controller in position.
                        Possible to measure enviro readings.
  -r <repeat>, --repeat <repeat>
                        Repeat selected measurement for R=1..N. Do nothing for
                        R=0,-1. Repeat endlessly for R=-2. Value ignored if
                        cfg provided.
  --sampleTime <sample_time>
                        Sample time for each range point.
  --nSamples <n_samples>
                        Number of samples for each range point.
  --debug               Bypass several options.
  --term                Immediately terminate all devices.
  --abort               Immediately abort all devices.

About

Multi-device control console application. Plug-n-Play design for serial RS232 and I2C connection. Considered device types: multimeters, HV sources, motion controller, environmental readings

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages