The regression is introduced when we allow apply "Extrusion rate smoothing" on vase mode in #4264
Specifically, at the transition point from normal printing to vase mode, the volumetric_extrusion_rate_end becomes significantly smaller than volumetric_extrusion_rate_start. This discrepancy can cause a feed rate of 0 if the extrusion rate smoothing value is set too low.
image from Discord member: NigelTufnel