fix: compatibility with navionics which only accepts $GP for RMC #42

Merged
merged 1 commit into from
Sep 6, 2019

Conversation

cmotelet
Copy link
Member

@cmotelet cmotelet commented Sep 4, 2019

This PR sets compatibility with navionics which only accepts $GP for RMC, GGA & GLL as talkerID (#41).
It is not yet possible to modify the talkerID in the signalk-server-node GUI.
A server evolution must be done to be able to update an existing configuration of a plugin without generating an error.

@tkurki tkurki merged commit 8586807 into SignalK:master Sep 6, 2019
@davidsanner
Copy link
Contributor

Just noticed this PR/commit. Seems like this could cause issues with current installs as users may be filtering based on $IIRMC like I do with kplex. (I have an always on GPS that outputs $GPRMC, when my N2K network is powered up kplex sees the $IIRMC output from signalk-to-nmea0183 and switches over to it.) Defaulting to $IIRMC and (at some point) adding the ability to modify the talkerID in the signalk-server-node GUI would be preferred to this work around. $SKRMC!

@cmotelet
Copy link
Member Author

cmotelet commented Sep 9, 2019

@davidsanner, the addition of the talkerID entry in the GUI is in progress. See #851 ( SignalK/signalk-server#871)