After experimenting with the simulator from https://github.com/RalfOGit/sma-emeter-simulator, it seems that the Sunny Tripower just want more obis data parts.
This pull requests adds a setting to enable full data mode, compatible with the STP 10.0 (testet on my local inverter). In full data mode, all power totals and the values for each phase are included in the data packet although only with static values.