fixed CJC calibration condition #1481

Merged
merged 1 commit into from
Nov 24, 2022
Merged
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
4 changes: 2 additions & 2 deletions source/Core/Threads/GUIThread.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -98,7 +98,7 @@ void performCJCC() {
// Calibrate Cold Junction Compensation directly at boot, before internal components get warm.
OLED::refresh();
osDelay(50);
if (!isTipDisconnected() && (TipThermoModel::getTipInC() - getHandleTemperature(0) / 10) < 10) {
if (!isTipDisconnected() && abs( int(TipThermoModel::getTipInC() - getHandleTemperature(0) / 10)) < 10) {
uint16_t setoffset = 0;
// If the thermo-couple at the end of the tip, and the handle are at
// equilibrium, then the output should be zero, as there is no temperature
Expand Down Expand Up @@ -1231,4 +1231,4 @@ void startGUITask(void const *argument) {
GUIDelay();
}
}
}
}