Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

8.3.0 alpha release notes draft #17141

Open
wants to merge 6 commits into
base: chore_release-8.3.0
Choose a base branch
from
Open
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
13 changes: 11 additions & 2 deletions api/release-notes.md
Original file line number Diff line number Diff line change
Expand Up @@ -8,9 +8,18 @@ By installing and using Opentrons software, you agree to the Opentrons End-User

---

## Opentrons Robot Software Changes in 8.3.0-alpha.0
## Opentrons Robot Software Changes in 8.3.0

Welcome to the v8.3.0 release of the Opentrons robot software! This release adds support for Evosep Evotips on the Flex, as well as other features.

### New Features
- Use Evosep Evotips in Python API version 2.22 protocols for protein sample purification. Only available with the Flex 96-channel pipette.
- Control robot movements outside of a protocol using the RobotContext API. For more, please read *link PAPI docs section*.
Copy link
Collaborator Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Adding robot context for now to release notes. Can remove as needed.

- Load a newly modified Flex 8-Channel EM 1000 µL pipette equipped with a PEEK motor component to automate emulsion applications.

### Improved Features
- Improvements to the Flex error recovery feature help protocols recover from detected stalls and collisions, saving you valuable time and resources.

Welcome to 8.3.0-alpha.0! This release solely adds support for the modified pipettes, outfitted with a PEEK motor nut to enable emulsification applications. Included is the recognition of new load name "FLEX 8-Channel EM 1000 μL" based on SN P1KP, which automatically disables pressure sensors and allows a max plunger speed of 90mm/s.

---

Expand Down
14 changes: 12 additions & 2 deletions app-shell/build/release-notes.md
Original file line number Diff line number Diff line change
Expand Up @@ -8,9 +8,19 @@ By installing and using Opentrons software, you agree to the Opentrons End-User

---

## Opentrons App Changes in 8.3.0-alpha.0
## Opentrons App Changes in 8.3.0

Welcome to 8.3.0-alpha.0! This release solely adds support for the modified pipettes, outfitted with a PEEK motor nut to enable emulsification applications. Included is the recognition of new load name "FLEX 8-Channel EM 1000 μL" based on SN P1KP, which automatically disables pressure sensors and allows a max plunger speed of 90mm/s.
Welcome to the v8.3.0 release of the Opentrons App! This release adds support for Evosep Evotips on the Flex, as well as other features.

### New Features

- Use Evosep Evotips in Python API version 2.22 protocols for protein sample purification. Only available with the Flex 96-channel pipette.
- Change the app or Flex touchscreen language to Mandarin in Settings.
- Load a newly modified Flex 8-Channel EM 1000 µL pipette equipped with a PEEK motor component to automate emulsion applications.

### Improved Features

- Improvements to the Flex error recovery feature help protocols recover from detected stalls and collisions, saving you valuable time and resources.

---

Expand Down
Loading