When a user connects to a robot with the new pipetting functions feature flag disabled, they should be shown a modal with copy instructing them to turn the feature flag on and explaining the effects of the feature flag (same as current behavior for P10S function--copy below).
The corresponding modal for the P10S feature flag should be removed.
[body]
This release includes an adjustment to the default aspirate behavior of the P10S, P10M, P50S, P50M, and P300S pipettes. The adjustment refines the ul to mm conversion for the pipettes to incrementally improve their accuracy.
Please be aware that this will result in a material change to the aspirated volumes of the pipettes. Though the results will be more accurate, a change to pipetting behavior may not be immediately desirable for some users.
For example, if you are in the middle of an experimental run and have updated to this new release, running a protocol post update will result in data that may be different from results using the previous release.
Additionally, if you have made any manual adjustments to the software to compensate for inaccuracy, those adjustments may not be compatible with the changes in this release and could result in inaccurate pipetting.
We strongly recommend you use these new calibrations. However, if you prefer to use the previous ul to mm conversion, you can revert to those settings in the 'Advanced Settings' menu. Please reach out to our team with any questions.
The text was updated successfully, but these errors were encountered:
overview
When a user connects to a robot with the new pipetting functions feature flag disabled, they should be shown a modal with copy instructing them to turn the feature flag on and explaining the effects of the feature flag (same as current behavior for P10S function--copy below).
The corresponding modal for the P10S feature flag should be removed.
Text:
[title]
Important: Pipette Calibration Update
[body]
This release includes an adjustment to the default aspirate behavior of the P10S, P10M, P50S, P50M, and P300S pipettes. The adjustment refines the ul to mm conversion for the pipettes to incrementally improve their accuracy.
Please be aware that this will result in a material change to the aspirated volumes of the pipettes. Though the results will be more accurate, a change to pipetting behavior may not be immediately desirable for some users.
For example, if you are in the middle of an experimental run and have updated to this new release, running a protocol post update will result in data that may be different from results using the previous release.
Additionally, if you have made any manual adjustments to the software to compensate for inaccuracy, those adjustments may not be compatible with the changes in this release and could result in inaccurate pipetting.
We strongly recommend you use these new calibrations. However, if you prefer to use the previous ul to mm conversion, you can revert to those settings in the 'Advanced Settings' menu. Please reach out to our team with any questions.