You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I recently got a DSO-2090USB, but when taking measurements, the zero reference line always seems to stay at the bottom of the screen, no matter where i put the channel's zero reference point.
Maybe i'm doing something wrong, because it also happens in the official windows software. https://youtu.be/KSA2VSFkci0
Anyone got a clue on what the problem might be?
The text was updated successfully, but these errors were encountered:
Thanks to fabio for his excellent article and response on his blog, I reflowed U20 (DAC) and its surrounding components, and the 2090 is working as it should again https://s22.postimg.org/s263vuhpd/dso_fixed.png
I recently got a DSO-2090USB, but when taking measurements, the zero reference line always seems to stay at the bottom of the screen, no matter where i put the channel's zero reference point.
Maybe i'm doing something wrong, because it also happens in the official windows software.
https://youtu.be/KSA2VSFkci0
Anyone got a clue on what the problem might be?
The text was updated successfully, but these errors were encountered: