The issue with looking for the first non negative value is it's possible for the temperature inside the openevse to be negative in very cold environments.
Is the value -256 a preset 'dummy' value for when no sensor is connected? Could we look for this instead?
It is, but unfortunately, older versions of the firmware returned zero or 230. I didn’t discover this until recently.. someone else wrote the code.
I changed it in D4.10.0
vD4.10.0 20170817 SCL
- change TMP007 temperature was showing up as 230 when not installed.
- also, temperature for other devices was 0 when not installed, but 0 is a
valid temperature
-> change all default temps to TEMPERATURE_NOT_INSTALLED (currently
-2560)
-> bump up RAPI version to 4.0.1
From: Glyn Hudson [mailto:[email protected]]
Sent: Monday, February 12, 2018 3:47 PM
To: OpenEVSE/ESP8266_WiFi_v2.x <[email protected]>
Cc: lincomatic <[email protected]>; Author <[email protected]>
Subject: Re: [OpenEVSE/ESP8266_WiFi_v2.x] negative temperature (#151)
The issue with looking for the first non negative value is it's possible for the temperature inside the openevse to be negative in very cold environments.
Is the value -256 a preset 'dummy' value for when no sensor is connected? Could we look for this instead?
glynhudson
changed the title
negative temperature
Detect dummy temperature sensor values
Jul 28, 2020
One of my EVSEs only has a MCP9808. As such, the only valid temperature is TEMP2. Therefore, my displayed temperature is garbage:
Would it be possible to test the temperatures for negative values in sequence, and use the first positive value encountered?