ovModbus

Modbus Data Extractor

Modbus Data Extractor is a Python script that allows you to extract data from Modbus devices using either TCP or RTU communication methods. The following main tasks can be called up:

  • General dump of the Modbus holding registers
  • Read out Ovum heat pump Modbus map
  • Create configuration for Home Assistant which then creates all Ovum heat pump parameters as sensors
  1. Installation
  2. Usage
  3. Examples
  4. Modbus TCP
  5. Modbus RTU
  6. Create a DUMP of a holding register
  7. Create a Ovum Heatpump Modbus Map
  8. Create a YAML/Configuration for Home Assistant and the sensors for Ovum heatpump
  9. All Options

Installation

Before using this script, you need to install the required Python libraries. You can do this using pip:

pip install pymodbus
pip install python-slugify

Usage

python ovModbus.py [OPTIONS]

Examples

Modbus TCP

python ovModbus.py TCP 247 --host 192.168.1.100 --port 502 [OPTIONS]

Modbus RTU

python ovModbus.py RTU 247 --comport /dev/ttyUSB0 --baudrate 19200 --parity E --stopbits 1 [OPTIONS]

1. Create Dump

Connect to Host 192.168.1.100 Port 502 and Slave 247

Read holding Register (as a Dump) address 12288 until address 18408 and save output in a file modbus.dump

python ovModbus.py TCP 247 --host 192.168.1.100 --port 502 --dump --start_address 12288 --stop_address 18408 --output modbus.dump

Output:

Idx	AddrHex	AddrDec	Hex	Byte_1	Byte_2	UInt16	Int16	Chr	Bin
0	0x3000	12288	00 00	0	0	0	0		0000 0000 0000 0000
1	0x3001	12289	30 0A	48	10	12298	12298		0011 0000 0000 1010
2	0x3002	12290	00 00	0	0	0	0		0000 0000 0000 0000
3	0x3003	12291	00 FE	0	254	254	254		0000 0000 1111 1110
4	0x3004	12292	00 00	0	0	0	0		0000 0000 0000 0000
5	0x3005	12293	80 00	128	0	32768	-32768		1000 0000 0000 0000
6	0x3006	12294	4D 45	77	69	19781	19781	ME	0100 1101 0100 0101
7	0x3007	12295	4E 55	78	85	20053	20053	NU	0100 1110 0101 0101
8	0x3008	12296	00 00	0	0	0	0		0000 0000 0000 0000
9	0x3009	12297	00 01	0	1	1	1		0000 0000 0000 0001
...

2. Read/Create Ovum Heatpumnp Modbus Map

Connect to Host 192.168.1.100 Port 502 and Slave 247

Read holding Register from Ovum Heatpump address 12288 until address 18408 and save output in a file modbus.ovum. Language is set to en

python ovModbus.py TCP 247 --host 192.168.1.100 --port 502 --start_address 12288 --stop_address 18408 --output modbus.ovum --lang en

Output:

AddrHex         AddrDec         Param           Int32           Prec            Value           Unit            UnitID          MultiID         MinVal          MaxVal          ReadOnly        isMenu          DescID          Desc
0x3000          12288           MENU                                                                                                                                                            True            0               
0x300a          12298           REAL                                                                                                                                                            True            3370            Heat Pump
0x3014          12308           Rps             0               0               0               rps             59                              0               130             True            False           5985            Inverter RPS set
0x301e          12318           HS              1               0               ON                              127             420             0               1               True            False           4568            Main switch
0x3028          12328           ALAR            0               0               No                              127             130             0               1               True            False           583             Active Alarm
0x3032          12338           Anfo            0               0               Standby                         127             865             0               255             True            False           4571            Operating Mode
0x303c          12348           CoMi            0               0               0               min             3                               0               65535           True            False           4569            Running time
0x3046          12358           CoHo            604             0               604             h               4                               0               65535           True            False           4570            Working hours
0x3050          12368           HePw            0               3               0.0             kW              35                              0               65535           True            False           4633            Heating power
0x305a          12378           PvWa            0               2               0.0             kW              35                              -32768          32767           True            False           5992            PVWatch power
0x3064          12388           ATvz            26              1               2.6             °C              0                               -32768          32767           True            False           4599            Ambient.t.avg.
...

3. Create Configuration for Home Assistant and add sensors of the Ovum Heatpumnp Modbus Map

Connect to Host 192.168.1.100 Port 502 and Slave 247

Read holding Register from Ovum Heatpump address 12288 until address 18408 and create HASS YAML and save it in a file ovum-modbus.yaml. Language is set to en

python ovModbus.py TCP 247 --host 192.168.1.100 --port 502 --hass --output ovum-modbus.yaml --lang en

Output:

modbus:
    - name: "modbus_ovum"
      type: tcp
      host: 192.168.1.100
      port: 502
      delay: 2
      message_wait_milliseconds: 0
      timeout: 5
      sensors:
        - name: "Heat pump: Inverter RPS set (Rps #12308)"         
          unique_id: ovum_Rps_sensor12308
          address: 12308
          scan_interval: 15                
          data_type: int32
          scale: 1
          precision: 0
          swap: word
          unit_of_measurement: "rps"
          input_type: holding
          min_value: 0
          max_value: 130
          slave: 247                    
          device_class: speed
        - name: "Heat pump: Main switch (HS #12318)"         
          unique_id: ovum_HS_sensor12318
          address: 12318
          scan_interval: 15                
          data_type: int32
          scale: 1
          precision: 0
          swap: word
          unit_of_measurement: " "
          input_type: holding
          min_value: 0
          max_value: 1
          slave: 247
      template:
        - sensor:
            - name: "Heat pump: Main switch (HS #12318) tmpl"
              unique_id: ovum_HS_sensor12318_tmpl            
              device_class: enum
              availability: "{{ states('sensor.heat_pump_main_switch_hs_12318')|int in [0,1] }}"
              state: >
                {% set mapper =  {
                    '0' : 'OFF',
                    '1' : 'ON' } %}            
                {% set state = states('sensor.heat_pump_main_switch_hs_12318') %}
                {{ mapper[state] if state in mapper}}
...

Options

  • method (str, TCP):
    • Description: How to connect (TCP or RTU).
  • slave (int, default: 247):
    • Description: The Modbus-Address (Slave).
  • --host (str, default: 127.0.0.1):
    • Description: The IP address of the Modbus TCP host.
  • --port (int, default: 502):
    • Description: The TCP-Port of the Modbus TCP host.
  • --comport (str, default: /dev/ttyUSB0):
    • Description: The COM Port Device.
  • --baudrate (int, default: 19200):
    • Description: Baudrate for RTU Connection.
  • --parity (str, default: E):
    • Description: Parity for RTU Connection.
  • --stopbits (int, default: 1):
    • Description: Stopbits for RTU Connection.
  • --lang (str, default: default):
    • Description: Language Selector (de, en, ...).
    • FOR GERMAN: Do not use this parameter.
  • --start_address (int, default: 12288):
    • Description: Start address of the register.
  • --stop_address (int, default: 18408):
    • Description: Stop address of the register.
  • --dump (boolean):
    • Description: Loop through addresses and dump content.
  • --csv (boolean):
    • Description: Output is in CSV-Format.
  • --hass (boolean):
    • Description: Create Home Assistant YAML for sensors.
  • --min (boolean):
    • Description: Create minimal output.
  • --noerror (boolean):
    • Description: Skip addresses with errors and do not print.
  • --output (str, default: None):
    • Description: Write output to a file.
  • --dev (boolean):
    • Description: Debugging and test parameter.