Shown timeline should be always the same #45

Closed
Fank opened this issue Mar 9, 2021 · 2 comments
Closed

Shown timeline should be always the same #45

Fank opened this issue Mar 9, 2021 · 2 comments
Labels
bug Something isn't working fixed next Hopefully fixed in next

Comments

@Fank
Copy link

Fank commented Mar 9, 2021

Bed, Tool 0 and CPU temperature shows alway a max of 10 minutes:
image

But Cooling fan speed shows a completly different timeline:
image

It looks like it only counts the time when this option is enabled:
image

@LazeMSS LazeMSS added the bug Something isn't working label Mar 17, 2021
@LazeMSS LazeMSS added the fixed next Hopefully fixed in next label Mar 25, 2021
@LazeMSS
Copy link
Owner

LazeMSS commented Mar 25, 2021

I have a fix on the way.

But the cooling fan speed is only updated when a gcode is sent to alter the speed thats why its sporadic.

LazeMSS added a commit that referenced this issue Mar 25, 2021
Fixed broken timeline on custom gcode etc - #45
@LazeMSS
Copy link
Owner

LazeMSS commented Mar 25, 2021

Fixed/closed in https://github.com/LazeMSS/OctoPrint-TopTemp/releases/tag/0.0.1.3

Please reopen if not fixed.

@LazeMSS LazeMSS closed this as completed Mar 25, 2021