Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

A lot of messages: "EventBus error 'OnEvent/deviceMessage': ZCL command ..... timed out after 10000ms" #23874

Open
Danieldiazi opened this issue Sep 6, 2024 · 25 comments
Labels
problem Something isn't working

Comments

@Danieldiazi
Copy link

What happened?

Hi,

With this device:

  • Model: ZWT199/ZWT100-BH
  • Zigbee Model TS0601
  • Manufactured: _TZE204_lzriup1j

imagen

I get a lot of "EventBus error" messages every second.

Thanks in advance for your support!

What did you expect to happen?

Don't have any of this messages

How to reproduce it (minimal and precise)

Only to pair this device in zigbee2mqtt and you will see those messages.

Zigbee2MQTT version

1.40.0

Adapter firmware version

20240510

Adapter

SLZB-06M

Setup

Docker container

Debug log

error 2024-09-06 14:16:41z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xXXXXXXXXX/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed ({"target":30621,"apsFrame":{"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":237},"zclSequence":40,"commandIdentifier":11} timed out after 10000ms) error 2024-09-06 14:16:53z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xXXXXXXXXX/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed ({"target":30621,"apsFrame":{"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":125},"zclSequence":98,"commandIdentifier":11} timed out after 10000ms) error 2024-09-06 14:17:24z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xXXXXXXXXX/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed ({"target":30621,"apsFrame":{"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":139},"zclSequence":177,"commandIdentifier":11} timed out after 10000ms) error 2024-09-06 14:17:34z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xXXXXXXXXX/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed ({"target":30621,"apsFrame":{"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":192},"zclSequence":188,"commandIdentifier":11} timed out after 10000ms) error 2024-09-06 14:17:55z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xXXXXXXXXX/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed ({"target":30621,"apsFrame":{"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":135},"zclSequence":128,"commandIdentifier":11} timed out after 10000ms) error 2024-09-06 14:18:51z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xXXXXXXXXX/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed ({"target":30621,"apsFrame":{"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":47},"zclSequence":133,"commandIdentifier":11} timed out after 10000ms) error 2024-09-06 14:19:11z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xXXXXXXXXX/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed ({"target":30621,"apsFrame":{"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":223},"zclSequence":61,"commandIdentifier":11} timed out after 10000ms)

@Danieldiazi Danieldiazi added the problem Something isn't working label Sep 6, 2024
@raaaf
Copy link

raaaf commented Sep 6, 2024

Same here.

@arkadi222
Copy link

same here. z2m 1.40.1 on docker unraid, skyconnect, emberznet

@arkadi222
Copy link

after comment 'external_converters' in configuration.yaml and restart z2m there are no that messages in log

@Danieldiazi
Copy link
Author

after comment 'external_converters' in configuration.yaml and restart z2m there are no that messages in log

In my case, I don't use external_converters option.

@Koenkk
Copy link
Owner

Koenkk commented Sep 16, 2024

It looks like the device is not reachable somehow, does it still happen when re-pairing it close to the coordinator?

@Danieldiazi
Copy link
Author

There are less than 1.5 meters between them.
They are in the same room. 1.5 meters is enough or maybe should I connect them closer together?

@Danieldiazi
Copy link
Author

It looks like the device is not reachable somehow, does it still happen when re-pairing it close to the coordinator?

Hi, I've tried to repair the device near the coordinator and the problem is the same. Any advice?

@mrtmsgh
Copy link

mrtmsgh commented Oct 1, 2024

Hi, I'm having the same problem with a similar device:

Model: ZWT198/ZWT100-BH
ZigBee Model: TS0601
Device: _TZE200_viy9ihs7

ZigBee adapter: SLZB-06M
ZigBee adapter firmware version: 20240510
Coordinator type: EmberZNet
Coordinator revision: 7.4.1 [GA]
ZigBee2MQTT version: 1.40.1
zigbee-herdsman-converters version: 20.12.1
zigbee-herdsman version: 0.57.3

After successfully pairing it, every ten seconds or so, I'm seeing a bunch of messages like these:

[20241001:174759] error: z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xb43a31fffe3d296a/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed (Delivery failed for {"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":143})
[20241001:174809] error: z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xb43a31fffe3d296a/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed (Delivery failed for {"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":229})
[20241001:174835] error: z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xb43a31fffe3d296a/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed (Delivery failed for {"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":73})

Thanks

@Danieldiazi
Copy link
Author

In order to add more information, I can confirm the problem exists with the newest 1.40.2 version.

@Koenkk
Copy link
Owner

Koenkk commented Oct 6, 2024

Could you check if the issue is fixed with the following external converter:

  • save this as file next to configuration.yaml as ext_converter.js
  • add it to configuration.yaml:
external_converters:
  - ext_converter.js
  • start z2m,
  • in the frontend, check if the description of this device now ends with CUSTOM (this indicates the external converter has been loaded correctly)
  • check if issue is fixed

@domome
Copy link

domome commented Oct 7, 2024

Hello,
It seems to be working in my case, there are no errors in the Z2M and HA logs.
Let's see what others say
Thanks

@Koenkk
Copy link
Owner

Koenkk commented Oct 7, 2024

@domome double check that all the features are still working

@domome
Copy link

domome commented Oct 7, 2024

@domome double check that all the features are still working

Yes, everything is working properly.

@Vangreen
Copy link

Vangreen commented Oct 7, 2024

Same here, now everything works ok, no more error logs. Thanks!

@Danieldiazi
Copy link
Author

Danieldiazi commented Oct 7, 2024

Same here too! It works great!! Any errors in the log file!

I wonder if it is possible to know what the problem was...

Thanks for your support @Koenkk !!

@mrtmsgh
Copy link

mrtmsgh commented Oct 9, 2024

The issue with my ZWT198 thermostat is all sorted out now. There are no more error messages in the logs, and it’s working perfectly. Huge thanks for all the hard work and support.

@domome
Copy link

domome commented Oct 9, 2024

@domome double check that all the features are still working

Hello
Doing an automation in HA I just checked that it seems that the Auto and Manual function are interchanged.
When Manual mode is set, the clock symbol appears on the thermostat (which is the automatic mode) and when Auto is set, a hand appears on the thermostat (which is the manual mode).
Can anyone else do this check?
Thank you.

@arkadi222
Copy link

@domome you can add comment here :)
#23998
please also confirm your manufacturer number : _TZE204_lzriup1j

@arkadi222
Copy link

temporary you can do what I did :)
#23998 (comment)

@domome
Copy link

domome commented Oct 9, 2024

@domome you can add comment here :) #23998 please also confirm your manufacturer number : _TZE204_lzriup1j

It is indeed that model.

I was looking at doing a test with something like:
[4, 'preset',
if (device.manufacturerName === '_TZE200_viy9ihs7') or (device.manufacturerName === '_TZE204_lzriup1j')

@Danieldiazi
Copy link
Author

Auto and Manual function are interchanged.

Same here

@mrtmsgh
Copy link

mrtmsgh commented Oct 9, 2024

The TZE200_viy9ihs7 has the same issue with the presets. I just discovered this after reading the latest comments here.

There’s a comment in #21353 that explains the order of presets for both models, and it seems that in the code, both are reversed.

@WolforOwl
Copy link

Hi All, i have similar issue but with
Zigbee Model TS0601
Zigbee Manufacturer _TZE200_g9a3awaj
Model [ZWT07]

Would this fix work on this model by adding external converter and changing model line?

@bachmarc
Copy link

bachmarc commented Nov 18, 2024

HI,
I have here a hand full of Sensors looking the same but identified as
Zigbee Model TS0601
Zigbee Manufactur _TZE204_upagmta9

which show same behavior and are very coupling only after several retries. Usually they look connected but send no metrics or parts of it. It feels like there are some individual sensors that do not like coupling or fall offline after some hours.

in ZIGBEE logs the error "EventBus error 'OnEvent/deviceMessage': ZCL command ..... timed out after 10000ms" is a frequent guest

Maybe the debug log helps? Here during a coupling

info 2024-11-18 18:00:07z2m: Accepting joining not in blocklist device '0xa4c13837935c5b8c' info 2024-11-18 18:00:07z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/0xa4c13837935c5b8c', payload '{"last_seen":"2024-11-18T18:00:08+01:00","linkquality":236}' info 2024-11-18 18:00:07zh:controller: Interview for '0xa4c13837935c5b8c' started info 2024-11-18 18:00:07z2m: Device '0xa4c13837935c5b8c' joined info 2024-11-18 18:00:07z2m: Starting interview of '0xa4c13837935c5b8c' info 2024-11-18 18:00:07z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/bridge/event', payload '{"data":{"friendly_name":"0xa4c13837935c5b8c","ieee_address":"0xa4c13837935c5b8c"},"type":"device_joined"}' info 2024-11-18 18:00:07z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/bridge/event', payload '{"data":{"friendly_name":"0xa4c13837935c5b8c","ieee_address":"0xa4c13837935c5b8c","status":"started"},"type":"device_interview"}' info 2024-11-18 18:00:07z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/0xa4c13837935c5b8c', payload '{"last_seen":"2024-11-18T18:00:08+01:00","linkquality":236}' info 2024-11-18 18:00:08z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/bridge/event', payload '{"data":{"friendly_name":"0xa4c13837935c5b8c","ieee_address":"0xa4c13837935c5b8c"},"type":"device_announce"}' error 2024-11-18 18:00:18z2m: EventBus error 'OnEvent/deviceAnnounce': ZCL command 0xa4c13837935c5b8c/1 manuSpecificTuya.dataQuery({}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed ({"target":30062,"apsFrame":{"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":240},"zclSequence":49,"commandIdentifier":11} timed out after 10000ms) info 2024-11-18 18:00:41z2m: Accepting joining not in blocklist device '0xa4c13837935c5b8c' info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/0xa4c13837935c5b8c', payload '{"last_seen":"2024-11-18T18:00:42+01:00","linkquality":236}' info 2024-11-18 18:00:41z2m: Accepting joining not in blocklist device '0xa4c13837935c5b8c' info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/0xa4c13837935c5b8c', payload '{"last_seen":"2024-11-18T18:00:42+01:00","linkquality":236}' info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/0xa4c13837935c5b8c', payload '{"last_seen":"2024-11-18T18:00:42+01:00","linkquality":236}' info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/bridge/event', payload '{"data":{"friendly_name":"0xa4c13837935c5b8c","ieee_address":"0xa4c13837935c5b8c"},"type":"device_announce"}' info 2024-11-18 18:00:41zh:controller: Succesfully interviewed '0xa4c13837935c5b8c' info 2024-11-18 18:00:41z2m: Successfully interviewed '0xa4c13837935c5b8c', device has successfully been paired info 2024-11-18 18:00:41z2m: Device '0xa4c13837935c5b8c' is supported, identified as: Tuya Temperature and humidity sensor (ZTH05) info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'homeassistant/sensor/0xa4c13837935c5b8c/temperature/config', payload '{"availability":[{"topic":"zigbee2mqtt/bridge/state","value_template":"{{ value_json.state }}"},{"topic":"zigbee2mqtt/0xa4c13837935c5b8c/availability","value_template":"{{ value_json.state }}"}],"availability_mode":"all","device":{"identifiers":["zigbee2mqtt_0xa4c13837935c5b8c"],"manufacturer":"Tuya","model":"Temperature and humidity sensor (ZTH05)","name":"0xa4c13837935c5b8c","via_device":"zigbee2mqtt_bridge_0x8c65a3fffe5485e4"},"device_class":"temperature","enabled_by_default":true,"object_id":"0xa4c13837935c5b8c_temperature","origin":{"name":"Zigbee2MQTT","sw":"1.41.0","url":"https://www.zigbee2mqtt.io"},"state_class":"measurement","state_topic":"zigbee2mqtt/0xa4c13837935c5b8c","unique_id":"0xa4c13837935c5b8c_temperature_zigbee2mqtt","unit_of_measurement":"°C","value_template":"{{ value_json.temperature }}"}' info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/bridge/event', payload '{"data":{"definition":{"description":"Temperature and humidity sensor","exposes":[{"access":1,"description":"Measured temperature value","label":"Temperature","name":"temperature","property":"temperature","type":"numeric","unit":"°C"},{"access":1,"description":"Measured relative humidity","label":"Humidity","name":"humidity","property":"humidity","type":"numeric","unit":"%"},{"access":1,"description":"State of the battery","label":"Battery state","name":"battery_state","property":"battery_state","type":"enum","values":["low","medium","high"]},{"access":3,"description":"Temperature unit","label":"Temperature unit","name":"temperature_unit","property":"temperature_unit","type":"enum","values":["celsius","fahrenheit"]},{"access":1,"category":"diagnostic","description":"Link quality (signal strength)","label":"Linkquality","name":"linkquality","property":"linkquality","type":"numeric","unit":"lqi","value_max":255,"value_min":0}],"model":"ZTH05","options":[{"access":2,"description":"Calibrates the temperature value (absolute offset), takes into effect on next report of device.","label":"Temperature calibration","name":"temperature_calibration","property":"temperature_calibration","type":"numeric"},{"access":2,"description":"Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it.","label":"Temperature precision","name":"temperature_precision","property":"temperature_precision","type":"numeric","value_max":3,"value_min":0},{"access":2,"description":"Calibrates the humidity value (absolute offset), takes into effect on next report of device.","label":"Humidity calibration","name":"humidity_calibration","property":"humidity_calibration","type":"numeric"},{"access":2,"description":"Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it.","label":"Humidity precision","name":"humidity_precision","property":"humidity_precision","type":"numeric","value_max":3,"value_min":0}],"supports_ota":false,"vendor":"Tuya"},"friendly_name":"0xa4c13837935c5b8c","ieee_address":"0xa4c13837935c5b8c","status":"successful","supported":true},"type":"device_interview"}' info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'homeassistant/sensor/0xa4c13837935c5b8c/humidity/config', payload '{"availability":[{"topic":"zigbee2mqtt/bridge/state","value_template":"{{ value_json.state }}"},{"topic":"zigbee2mqtt/0xa4c13837935c5b8c/availability","value_template":"{{ value_json.state }}"}],"availability_mode":"all","device":{"identifiers":["zigbee2mqtt_0xa4c13837935c5b8c"],"manufacturer":"Tuya","model":"Temperature and humidity sensor (ZTH05)","name":"0xa4c13837935c5b8c","via_device":"zigbee2mqtt_bridge_0x8c65a3fffe5485e4"},"device_class":"humidity","enabled_by_default":true,"object_id":"0xa4c13837935c5b8c_humidity","origin":{"name":"Zigbee2MQTT","sw":"1.41.0","url":"https://www.zigbee2mqtt.io"},"state_class":"measurement","state_topic":"zigbee2mqtt/0xa4c13837935c5b8c","unique_id":"0xa4c13837935c5b8c_humidity_zigbee2mqtt","unit_of_measurement":"%","value_template":"{{ value_json.humidity }}"}' info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/0xa4c13837935c5b8c', payload '{"last_seen":"2024-11-18T18:00:42+01:00","linkquality":236,"temperature":null}' info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'homeassistant/sensor/0xa4c13837935c5b8c/battery_state/config', payload '{"availability":[{"topic":"zigbee2mqtt/bridge/state","value_template":"{{ value_json.state }}"},{"topic":"zigbee2mqtt/0xa4c13837935c5b8c/availability","value_template":"{{ value_json.state }}"}],"availability_mode":"all","device":{"identifiers":["zigbee2mqtt_0xa4c13837935c5b8c"],"manufacturer":"Tuya","model":"Temperature and humidity sensor (ZTH05)","name":"0xa4c13837935c5b8c","via_device":"zigbee2mqtt_bridge_0x8c65a3fffe5485e4"},"enabled_by_default":true,"name":"Battery state","object_id":"0xa4c13837935c5b8c_battery_state","origin":{"name":"Zigbee2MQTT","sw":"1.41.0","url":"https://www.zigbee2mqtt.io"},"state_topic":"zigbee2mqtt/0xa4c13837935c5b8c","unique_id":"0xa4c13837935c5b8c_battery_state_zigbee2mqtt","value_template":"{{ value_json.battery_state }}"}' info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'homeassistant/sensor/0xa4c13837935c5b8c/temperature_unit/config', payload '{"availability":[{"topic":"zigbee2mqtt/bridge/state","value_template":"{{ value_json.state }}"},{"topic":"zigbee2mqtt/0xa4c13837935c5b8c/availability","value_template":"{{ value_json.state }}"}],"availability_mode":"all","device":{"identifiers":["zigbee2mqtt_0xa4c13837935c5b8c"],"manufacturer":"Tuya","model":"Temperature and humidity sensor (ZTH05)","name":"0xa4c13837935c5b8c","via_device":"zigbee2mqtt_bridge_0x8c65a3fffe5485e4"},"enabled_by_default":false,"name":"Temperature unit","object_id":"0xa4c13837935c5b8c_temperature_unit","origin":{"name":"Zigbee2MQTT","sw":"1.41.0","url":"https://www.zigbee2mqtt.io"},"state_topic":"zigbee2mqtt/0xa4c13837935c5b8c","unique_id":"0xa4c13837935c5b8c_temperature_unit_zigbee2mqtt","value_template":"{{ value_json.temperature_unit }}"}' info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'homeassistant/select/0xa4c13837935c5b8c/temperature_unit/config', payload '{"availability":[{"topic":"zigbee2mqtt/bridge/state","value_template":"{{ value_json.state }}"},{"topic":"zigbee2mqtt/0xa4c13837935c5b8c/availability","value_template":"{{ value_json.state }}"}],"availability_mode":"all","command_topic":"zigbee2mqtt/0xa4c13837935c5b8c/set/temperature_unit","device":{"identifiers":["zigbee2mqtt_0xa4c13837935c5b8c"],"manufacturer":"Tuya","model":"Temperature and humidity sensor (ZTH05)","name":"0xa4c13837935c5b8c","via_device":"zigbee2mqtt_bridge_0x8c65a3fffe5485e4"},"enabled_by_default":true,"name":"Temperature unit","object_id":"0xa4c13837935c5b8c_temperature_unit","options":["celsius","fahrenheit"],"origin":{"name":"Zigbee2MQTT","sw":"1.41.0","url":"https://www.zigbee2mqtt.io"},"state_topic":"zigbee2mqtt/0xa4c13837935c5b8c","unique_id":"0xa4c13837935c5b8c_temperature_unit_zigbee2mqtt","value_template":"{{ value_json.temperature_unit }}"}' info 2024-11-18 18:00:42z2m:mqtt: MQTT publish: topic 'homeassistant/sensor/0xa4c13837935c5b8c/linkquality/config', payload '{"availability":[{"topic":"zigbee2mqtt/bridge/state","value_template":"{{ value_json.state }}"},{"topic":"zigbee2mqtt/0xa4c13837935c5b8c/availability","value_template":"{{ value_json.state }}"}],"availability_mode":"all","device":{"identifiers":["zigbee2mqtt_0xa4c13837935c5b8c"],"manufacturer":"Tuya","model":"Temperature and humidity sensor (ZTH05)","name":"0xa4c13837935c5b8c","via_device":"zigbee2mqtt_bridge_0x8c65a3fffe5485e4"},"enabled_by_default":false,"entity_category":"diagnostic","icon":"mdi:signal","name":"Linkquality","object_id":"0xa4c13837935c5b8c_linkquality","origin":{"name":"Zigbee2MQTT","sw":"1.41.0","url":"https://www.zigbee2mqtt.io"},"state_class":"measurement","state_topic":"zigbee2mqtt/0xa4c13837935c5b8c","unique_id":"0xa4c13837935c5b8c_linkquality_zigbee2mqtt","unit_of_measurement":"lqi","value_template":"{{ value_json.linkquality }}"}' info 2024-11-18 18:00:42z2m:mqtt: MQTT publish: topic 'homeassistant/sensor/0xa4c13837935c5b8c/last_seen/config', payload '{"availability":[{"topic":"zigbee2mqtt/bridge/state","value_template":"{{ value_json.state }}"},{"topic":"zigbee2mqtt/0xa4c13837935c5b8c/availability","value_template":"{{ value_json.state }}"}],"availability_mode":"all","device":{"identifiers":["zigbee2mqtt_0xa4c13837935c5b8c"],"manufacturer":"Tuya","model":"Temperature and humidity sensor (ZTH05)","name":"0xa4c13837935c5b8c","via_device":"zigbee2mqtt_bridge_0x8c65a3fffe5485e4"},"device_class":"timestamp","enabled_by_default":false,"entity_category":"diagnostic","icon":"mdi:clock","name":"Last seen","object_id":"0xa4c13837935c5b8c_last_seen","origin":{"name":"Zigbee2MQTT","sw":"1.41.0","url":"https://www.zigbee2mqtt.io"},"state_topic":"zigbee2mqtt/0xa4c13837935c5b8c","unique_id":"0xa4c13837935c5b8c_last_seen_zigbee2mqtt","value_template":"{{ value_json.last_seen }}"}'

@AppleFlapp
Copy link

AppleFlapp commented Jan 2, 2025

Same here with ZTH01 temperature sensor.

Zigbee Model: TS0601
Zigbee Manufacturer: _TZE204_yjjdcqsq

Zigbee2MQTT version 1.42.0

Message keeps popping up even after the devices is removed from the Z2M configuration.

2025-01-02 19:17:30z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xa4c138d6e76a7d2f/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed (Timeout - 29665 - 1 - 44 - 61184 - 11 after 10000ms)
error 2025-01-02 19:17:53z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xa4c138d6e76a7d2f/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed (Timeout - 29665 - 1 - 45 - 61184 - 11 after 10000ms)
error 2025-01-02 19:18:17z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xa4c138d6e76a7d2f/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed (Timeout - 29665 - 1 - 46 - 61184 - 11 after 10000ms)

Edit:
Paired the device again, did a reboot of the HA system (not HA but the system), removed the device and now the issue is gone.
I am not sure if the error did not show up anymore after the system reboot. I did remove it as I didn't want to use it anymore anyway. But it is worth the try to reboot your system to see if the error disappears.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
problem Something isn't working
Projects
None yet
Development

No branches or pull requests

10 participants