# Zizm ZM194-D9Y | ||
|
||
This [Enapter Device Blueprint](https://go.enapter.com/marketplace-readme) integrates **Zizm ZM194-D9Y** - 3-Phase Multi-function Power Meter with [ModBus RTU](https://go.enapter.com/developers-enapter-modbus) over [RS-485 communication interface](https://go.enapter.com/developers-enapter-rs485). | ||
|
||
## Connect to Enapter | ||
|
||
- Sign up to the Enapter Cloud using the [Web](https://cloud.enapter.com/) or mobile app ([iOS](https://apps.apple.com/app/id1388329910), [Android](https://play.google.com/store/apps/details?id=com.enapter&hl=en)). | ||
- Use the [Enapter ENP-RS485](https://go.enapter.com/handbook-enp-rs485) module for physical connection. See [connection instructions](https://go.enapter.com/handbook-enp-rs485-conn) in the module manual. | ||
- [Add ENP-RS485 to your site](https://go.enapter.com/handbook-mobile-app) using the mobile app. | ||
- [Upload](https://go.enapter.com/developers-upload-blueprint) this blueprint to ENP-RS485. | ||
- Use the `Set Up Connection` command in the Enapter mobile or Web app to set up Modbus RTU communication parameters: | ||
- Baudrate; | ||
- Modbus address; | ||
- Parity. |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,194 @@ | ||
local config = require('enapter.ucm.config') | ||
|
||
BAUDRATE = 'baudrate' | ||
ADDRESS = 'address' | ||
PARITY = 'parity' | ||
|
||
-- Default RS485 communication interface parameters | ||
DATA_BITS = 8 | ||
STOP_BITS = 1 | ||
|
||
function main() | ||
config.init({ | ||
[BAUDRATE] = { type = 'number', required = true, default = 9600 }, | ||
[ADDRESS] = { type = 'number', required = true, default = 1 }, | ||
[PARITY] = { type = 'string', required = true, default = 'N' }, | ||
}) | ||
|
||
local values, err = config.read_all() | ||
if err then | ||
enapter.log('cannot read config: ' .. tostring(err), 'error') | ||
return nil, 'cannot_read_config' | ||
else | ||
local baudrate, parity = values[BAUDRATE], values[PARITY] | ||
|
||
local result = rs485.init(baudrate, DATA_BITS, parity, STOP_BITS) | ||
if result ~= 0 then | ||
enapter.log('RS485 init error: ' .. rs485.err_to_str(result), error, true) | ||
end | ||
end | ||
|
||
scheduler.add(30000, send_properties) | ||
scheduler.add(1000, send_telemetry) | ||
end | ||
|
||
function send_properties() | ||
enapter.send_properties({ | ||
vendor = 'Zizm', | ||
model = 'ZM194-D9Y', | ||
}) | ||
end | ||
|
||
function send_telemetry() | ||
local telemetry = {} | ||
local status = 'ok' | ||
|
||
local all_metrics = { | ||
voltage_a = { | ||
register_address = 0x0000, | ||
register_count = 2, | ||
fn = touint32, | ||
}, | ||
voltage_b = { | ||
register_address = 0x0002, | ||
register_count = 2, | ||
fn = touint32, | ||
}, | ||
voltage_c = { | ||
register_address = 0x0004, | ||
register_count = 2, | ||
fn = touint32, | ||
}, | ||
line_voltage_ab = { | ||
register_address = 0x0006, | ||
register_count = 2, | ||
fn = touint32, | ||
}, | ||
line_voltage_bc = { | ||
register_address = 0x0008, | ||
register_count = 2, | ||
fn = touint32, | ||
}, | ||
line_voltage_ca = { | ||
register_address = 0x000A, | ||
register_count = 2, | ||
fn = touint32, | ||
}, | ||
current_a = { | ||
register_address = 0x000C, | ||
register_count = 2, | ||
fn = touint32, | ||
}, | ||
current_b = { | ||
register_address = 0x000E, | ||
register_count = 2, | ||
fn = touint32, | ||
}, | ||
current_c = { | ||
register_address = 0x0010, | ||
register_count = 2, | ||
fn = touint32, | ||
}, | ||
active_power_a = { | ||
register_address = 0x0012, | ||
register_count = 2, | ||
fn = touint32, | ||
}, | ||
active_power_b = { | ||
register_address = 0x0014, | ||
register_count = 2, | ||
fn = touint32, | ||
}, | ||
active_power_c = { | ||
register_address = 0x0016, | ||
register_count = 2, | ||
fn = touint32, | ||
}, | ||
total_active_power = { | ||
register_address = 0x0018, | ||
register_count = 2, | ||
fn = touint32, | ||
}, | ||
reactive_power_a = { | ||
register_address = 0x001A, | ||
register_count = 2, | ||
fn = touint32, | ||
}, | ||
reactive_power_b = { | ||
register_address = 0x001C, | ||
register_count = 2, | ||
fn = touint32, | ||
}, | ||
reactive_power_c = { | ||
register_address = 0x001E, | ||
register_count = 2, | ||
fn = touint32, | ||
}, | ||
total_reactive_power = { | ||
register_address = 0x0020, | ||
register_count = 2, | ||
fn = touint32, | ||
}, | ||
frequency = { | ||
register_address = 0x0032, | ||
register_count = 2, | ||
fn = touint32, | ||
}, | ||
total_active_electric_energy = { | ||
register_address = 0x0038, | ||
register_count = 2, | ||
fn = touint32, | ||
}, | ||
forward_active_electric_energy = { | ||
register_address = 0x003A, | ||
register_count = 2, | ||
fn = touint32, | ||
}, | ||
reverse_active_electric_energy = { | ||
register_address = 0x003C, | ||
register_count = 2, | ||
fn = touint32, | ||
}, | ||
} | ||
|
||
for name, metric in pairs(all_metrics) do | ||
if | ||
not add_to_telemetry( | ||
name, | ||
telemetry, | ||
metric.register_address, | ||
metric.register_count, | ||
metric.fn | ||
) | ||
then | ||
status = 'read_error' | ||
end | ||
end | ||
|
||
telemetry['status'] = status | ||
enapter.send_telemetry(telemetry) | ||
end | ||
|
||
function add_to_telemetry(metric_name, tbl, register_address, registers_count, fn) | ||
local address, err = config.read(ADDRESS) | ||
if err == nil then | ||
local data, result = modbus.read_holdings(address, register_address, registers_count, 1000) | ||
if data then | ||
tbl[metric_name] = fn(data) / 1000.0 -- coefficient 0.001 for all metrics | ||
return true | ||
else | ||
enapter.log( | ||
'Register ' .. register_address .. ' reading failed: ' .. modbus.err_to_str(result) | ||
) | ||
end | ||
end | ||
return false | ||
end | ||
|
||
function touint32(register) | ||
local raw_str = | ||
string.pack('BBBB', register[1] >> 8, register[1] & 0xff, register[2] >> 8, register[2] & 0xff) | ||
return string.unpack('>I2', raw_str) | ||
end | ||
|
||
main() |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,189 @@ | ||
blueprint_spec: device/1.0 | ||
display_name: Zizm ZM194-D9Y | ||
description: 3-Phase Multi-function Power Meter. | ||
icon: enapter-power-meter | ||
vendor: zizm | ||
author: enapter | ||
support: | ||
url: https://go.enapter.com/enapter-blueprint-support | ||
email: [email protected] | ||
license: MIT | ||
verification_level: verified | ||
|
||
communication_module: | ||
product: ENP-RS485 | ||
lua: | ||
file: firmware.lua | ||
dependencies: | ||
- enapter-ucm | ||
|
||
properties: | ||
vendor: | ||
type: string | ||
display_name: Vendor | ||
model: | ||
type: string | ||
display_name: Model | ||
|
||
telemetry: | ||
status: | ||
display_name: Modbus status | ||
type: string | ||
enum: | ||
- ok | ||
- read_error | ||
total_active_power: | ||
type: float | ||
unit: kwatt | ||
display_name: Total Active Power | ||
total_active_electric_energy: | ||
type: float | ||
unit: kwatth | ||
display_name: Total Active Electric Energy | ||
active_power_a: | ||
type: float | ||
unit: kwatt | ||
display_name: Active Power A | ||
active_power_b: | ||
type: float | ||
unit: watt | ||
display_name: Active Power B | ||
active_power_c: | ||
type: float | ||
unit: kwatt | ||
display_name: Active Power C | ||
voltage_a: | ||
type: float | ||
unit: volt | ||
display_name: Phase A Voltage | ||
voltage_b: | ||
type: float | ||
unit: volt | ||
display_name: Phase B Voltage | ||
voltage_c: | ||
type: float | ||
unit: volt | ||
display_name: Phase C Voltage | ||
line_voltage_ab: | ||
type: float | ||
unit: volt | ||
display_name: Line Voltage AB | ||
line_voltage_bc: | ||
type: float | ||
unit: volt | ||
display_name: Line Voltage BC | ||
line_voltage_ca: | ||
type: float | ||
unit: volt | ||
display_name: Line Voltage CA | ||
current_a: | ||
type: float | ||
unit: amp | ||
display_name: Phase A Current | ||
current_b: | ||
type: float | ||
unit: amp | ||
display_name: Phase B Current | ||
current_c: | ||
type: float | ||
unit: amp | ||
display_name: Phase C Current | ||
frequency: | ||
type: float | ||
unit: hertz | ||
display_name: Frequency | ||
total_reactive_power: | ||
type: float | ||
unit: watt | ||
display_name: Total Reactive Power | ||
reactive_power_a: | ||
type: float | ||
unit: watt | ||
display_name: Reactive Power A | ||
reactive_power_b: | ||
type: float | ||
unit: watt | ||
display_name: Reactive Power B | ||
reactive_power_c: | ||
type: float | ||
unit: watt | ||
display_name: Reactive Power C | ||
forward_active_electric_energy: | ||
type: float | ||
unit: kwatth | ||
display_name: Forward Active Electric Energy | ||
reverse_active_electric_energy: | ||
type: float | ||
unit: kwatth | ||
display_name: Reverse Active Electric Energy | ||
|
||
command_groups: | ||
connection: | ||
display_name: Connection | ||
|
||
commands: | ||
# TODO: mark commands containing secrets | ||
write_configuration: | ||
display_name: Set Up Connection | ||
description: Set Modbus RTU connection | ||
group: connection | ||
populate_values_command: read_configuration | ||
ui: | ||
icon: file-document-edit-outline | ||
arguments: | ||
baudrate: | ||
display_name: Baudrate | ||
type: integer | ||
required: true | ||
enum: | ||
- 2400 | ||
- 4800 | ||
- 9600 | ||
address: | ||
display_name: Modbus address | ||
type: integer | ||
required: true | ||
min: 1 | ||
max: 247 | ||
parity: | ||
display_name: Parity | ||
type: string | ||
required: true | ||
enum: | ||
- N | ||
- E | ||
- O | ||
read_configuration: | ||
display_name: Read Connection Parameters | ||
group: connection | ||
ui: | ||
icon: file-check-outline | ||
.cloud: | ||
category: power_meters | ||
mobile_main_chart: total_active_power | ||
mobile_telemetry: | ||
- total_active_electric_energy | ||
- total_active_power | ||
- active_power_a | ||
- active_power_b | ||
- active_power_c | ||
- voltage_a | ||
- voltage_b | ||
- voltage_c | ||
- current_a | ||
- current_b | ||
- current_c | ||
- frequency | ||
mobile_charts: | ||
- total_active_electric_energy | ||
- total_active_power | ||
- active_power_a | ||
- active_power_b | ||
- active_power_c | ||
- voltage_a | ||
- voltage_b | ||
- voltage_c | ||
- current_a | ||
- current_b | ||
- current_c | ||
- frequency |