- Introduced bind_addr parameter in Device() API #1279
- Introduced vmhost paramater in dev.facts #1333
- Introduced hostkey_verify paramater in Device() API #1321
- Updated Docker file to use the latest Alpine #1316
- Fixed the missing key to EthernetSwitchingTable #1228
- Fixed error handling on HelloHandler #1339
- Fixed the version check #1338
- Removed Google and Stackflow link from the ReadME #1337
- Fixed SystemStorageTable tables and views to handles multiple routing-engine file system storage information.#1244
- Fixed Console' object has no attribute '_use_filter' error when executed Table/View script #1335
- Fixed cli function to get full RPC response #1315
- Fixed sw.install to set no_validate option when validate=False for NSSU and ISSU upgrade #1323
- Fixed UT framework mock to use built-in unittest.mock #1311
- Fixed specific VC member reboot handling #1308 #1310
- Supported latest paramiko version which supports aes128-gcm and aes256-gcm cipher
- Added customer juniper paramiko module as a dependency which supported aes128 and aes257 cipher #1299
- Support added for Python 3.10 and above version
- Introduced optional argument routing instance for fs.cp() API
- Intoduced optional argument member_id for installation of pkg on specific member id of EX-VC
- Changed the VlanTable field name to vlan-name and BfdSessionTable field name to client-bame #423
- Fixed the port details in StartShell to use the port from Device object instead of default Port 22 #573
- Fixed the sw.install to use Windows file path for package copy #1206
- Fixed the sw.install to install the vc_master after the other vc_members gets installed for EX-3400 where unlink is set by default #1247
- Removed Unused Dependency: Netaddr #1257
- Fixed "object": version_info(re_version) emits ValueError: invalid literal for int() with base 10: '17-EVO' for EVO version X50.17-EVO#1264
- Fixed reboot failing on other RE #1199
- Fixed passing 'sleep' arg to StartShell run() #1202
- Fixed PyEZ get-facts support for ACX model #1209
- Fixed EthPortTable regex pattern #1215
- Fixed StartShell UnboundLocalError #1203 #1211
- Supported multi-gig ports for EthPortTable.yml #1177
- Fixed on-box support for start shell types #1190 #1186
- Fixed conn_open_timeout value was getting set to None , changed to default 30 seconds #1184
- Supported start_shell options to choose the shell types (sh or csh) #995
- Supported for python 3.9
- Fixed Device facts current_re returns the SRX cluster node0 and node1 details with cluster ID 16 #1135
- Fixed upgrade ncclient version 0.6.13, updated requirements.txt to install ncclient==0.6.13 #1153
- Fixed deprecation warning due to invalid escape sequences #1034
- Fixed Unit tests test_sw_put_ftp failure #1165
- None
- Latest
textfsm
doesn’t support in windows. Hence, supportingtextfsm 0.4.1
for windows user #1019 - Convert
port
argument when passed asstr
toint
data type #1020 - Return type of
sw.install
function going to change in the upcoming major release. So, added a deprecation warning insw.install
#1025
- Added TableView Null Key support #983
- Added timeout support for commit_check() #998
- Added Win serial COM support #1000
- Added load patch support #1001
- Added textfsm support for table/view #1009
- Fixed table/view issue w.r.t to get() call #981
- Fixed documentation typo #986
- Handled sax parser input for nested fields #997
- Fixed outbound ssh issue #1007
- Fixed xpath issue when defined with a string function #1008
- None
- Handled a check for pending Junos OS or package installation #966
- Fixed MetaPathLoader support only for jnpr.junos* modules #977
- Fixed huge tree XML support #975
- Fixed Junos sax parser issue for filter_xml broken #969
- TableView extended for vty/cli unstructured command #950
- Added junos SAX parser feature #942 #955 #951
- Added TableView Null Key support #910
- Added command tables #958.
- Added reboot support for junos vmhost platform #952
- Added ElsEthernetSwitchingTable TableView #939
- Added callback functionality to ftp get #932
- Extended start shell support for Bourne shell #934
- Added
at
option support forsw.reboot()
andsw.poweroff()
#916 - Added generalized function for ssh-client #957
- Updated fact collection for srx platform #935
- Supports new ssh private key format #945
- Handled exception in dev.close() #956
- Updated file transfers to use context manager to open files #885
- Fixed reboot and poweroff behavior #916
- None
- Handle multiple package-result values from sw.install #864
- Extended support to WR-Based Linux H/W #882 #883 #889
- Fixed issues in Console over SSH #877
- Optimized PyEZ docker image size and minor bug fixes #894 #911
- Fixed JSON serialization for Junos facts #902
- Updated securityzone.yml. Added item
zone-security
#909 - Fixed runtime error while using Outbound-SSH #915
- Fixed Pyyaml bugs #914 #917 #918
- Support for Node virt based platforms #856
- Support Linux based Junos devices #862
- Connection through console server (having login credentials) using SSH #861 #870
- outbound ssh #732
- None
- Added op tables and views for SRX security zones #855
- Changed facts for DVATIA platform #856
- Fixed issue in gathering facts when other RE is rebooting/off #852
- Added and fixed existing unit test cases in PyEZ #838 #854 #840
- Fixed RpcTimeoutError for pdiff() #839
- Handled newer junos device #853
-None
- Correct PyEZ TechWiki link #813
- Support active and inactive configuration options in config table/view #826
- Upgraded alpine 3.6 to support docker in PyEZ #789 #828 #827
- Support configuration table/view in telnet mode #829
- Added new unit test cases in PyEZ #831
- Detect set config format with all keywords like insert, activate, copy etc #791 #792
- None
- Correct PyEZ TechWiki link. #781/#783
- SRX Branch cluster fails SW.install(). #782
- PyEZ fact gathering support for JDM of Junos Node Slicing. #761
- Enhanced support for GNFs in Junos Node Slicing. #761
- Add vmhost parameter to SW.install() to support upgrading the VM Host. #773
- Fix typo in docker run example. #771
- Aadding ietf-softwire get_config() example. #772
- Fix for python3 remove_ns issue. #767
- Fix python2/3 compatibility. #776
- Single-RE sw install on multi-RE device using all_re argument to SW.install() #746
- Support platforms which have single-RE ISSU. #740
- Support Config.load() loading a configuration from a URL. #749
- SW.install() enhanced to install from a URL. #751
- Implement uptime property for Device instances. #752/#750
- Facts gathering support for Junos Node Slicing. #760
- Refactor _exec_rpc() and handle boolean RPC arguments with a value of False. #739
- Add the _j2ldr instance variable to the Console class. #753
- Properly handle normalize argument to the open() Device method. #758/#757
- Setting no-resolve to true for faster ARP Table lookups. #762
- Optimize image copying in SW.safe_copy() #728
- unnecessary import cleanup #730
- Explicitly initialize jnpr.junos.facts sub-modules. #723/#731
- socket.error handling for console->close() #734
- Ensure dev.timeout is an integer value. Addresses #735/#736
- Socket error fix #737
- Ephemeral config support #707
- Add a srx_cluster_redundancy_group fact. #711
- ignore_warning fails when single that is first child of . #712
- mode='telnet' did not logout non-cli user #713
- JSONLoadError was thrown when load valid JSON config #717/#718
- Fix XML normalization feature when using NETCONF over console. #719/#720
- Handle differences in |display xml rpc #722
- Doc badge was pointing to older version #694
- Fix new-style fact gathering for SRX clusters. #697/#698
- Properly handle SW upgrades on multi-RE and/or multi-chassis systems when using new-style fact gathering. #700
- Raise JSONLoadError if json config is malformed #706
- Handle ConnectClosedError exception for lock() and unlock() #708
- Return None when the RPC equiv is either str or unicode #721
- Fix regressions caused by
ignore_warning
. #691
- Enhanced fact gathering. Facts are now gathered "on demand." Additional facts are added. The definition of facts and return values are properly documented. #638
- Support for YANG get RPCs. #672
- Add an
ignore_warning
argument to suppressRpcError
exceptions for warnings. #672/#685 - Enhanced the
sw.install()
method with basic ISSU and NSSU support using the issu and nssu boolean arguments. #606/#630/#632 ** NSSU support has not yet been tested and should currently be considered experimental. - Provide a master property and a re_name property for Device. #682
- Enhanced
reboot()
method to take anall_re
boolean parameter which controls if only the connected Routing Engine, or all Routing Engines, are rebooted. #613 - Enhanced the warning message produced by the
cli()
method to recommend the correspondingdev.rpc.<method>()
call. #603 - Add support for
update
parameter to configurationload()
method. #681 - Added
directory_usage
to utils #629/#631/#636 - Adding support for NFX/JDM fact gathering. #652/#659
- Connected property. #664
- Updated the interface-name glob pattern to correctly match
et-<x>/<y>/<z>
interfaces in several tables and views. #609 - Take care of special chars on screen during console connection. #610
- Address issue with fact gathering stopping when it encounters a problem. #615
- Minor typos fixed in
RuntimeError
exception message and in comments. #621 - Added
console_has_banner
parameter. #622 - Add CentOS Support to install instructions #623
- Key value is needed in
_IsisAdjacencyLogTable
#627 - Improved functionality and documentation of Docker build. #637/#673/#674/#677
- added remote port ID to lldp.yml (OP) #645
- Fix documentation for
rollback()
#647 - Fix for fact gathering pprint. #660/#661
- update ospf view, add bgp/inventory #665
- Updated doc string for close function #686
- Add Travis builds for Python 3.5 and 3.6 #687
- StartShell.run to take this as None for non returning commands #680
- Modify ignore_warning return value to mimic normal RPC return value. #688
- StartShell to take timeout (30 second by default) as paramter
- Proper exception handling in case of Console connection #595
- Fix: Config.lock() return exception when normalize is on
- Added microbadge badge for the Docker image #593
- Fix: print dev for Console conn was printing object not Device(....) #591
- Fix: To take care of special chars with StartShell->run function call #589
- Fix: ssh private key file to be considered for scp util #586
- Added Dockerfile to enable automated image builds on project commits #585
- Console connection using PyEZ
- Python >=3.4 support
- Configuration Tables to Define and Configure Structured Resources
- JSON Config load
- FTP Utility
- Multi RPC error
- various bug fixes
Refer below link for more details: https://github.com/Juniper/py-junos-eznc/releases/tag/2.0.0
The Junos PyEZ project is an open-source Apache 2.0 library for the Python programming language. The purpose of this "micro-framework" library is to enable the networking professional community to effectively utilize the Junos OS NETCONF and XML APIs.
The Junos PyEZ library can be used on any number of server environments supporting Python 2.6 and 2.7.
At the time of this writing, Junos PyEZ is not distributed on devices running Junos OS.
For feature documentation and community support, refer to the following URLs:
- Project Page hosted on the Juniper Networks TechWiki: http://techwiki.juniper.net/Automation_Scripting/Junos_PyEZ
- Source code hosted on Github: https://github.com/Juniper/py-junos-eznc
- Support forum hosted using Google Groups: https://groups.google.com/forum/#!forum/junos-python-ez
Junos PyEZ can be installed directly from the PyPi repository by typing pip install junos-eznc
at the system command line.
The "pip" installation process also installs any related dependent Python modules and libraries. Depending on your specific system, you might need to have the prerequisite build tools installed as well.
For the complete set of installation instructions for various platforms, see the Junos PyEZ project documentation at https://techwiki.juniper.net/Automation_Scripting/Junos_PyEZ/Installation.
Junos PyEZ can be used with any device running Junos OS, because they all support the NETCONF and Junos XML APIs. To take full advantage of the Junos PyEZ features, we recommend using Junos OS Release 11.4 or later release - see "Known Limitations and Restrictions" section for details. For more information about Junos OS releases, refer to the Juniper Networks technical documentation site at https://www.juniper.net/techpubs/en_US/release-independent/junos/information-products/pathway-pages/junos/product/index.html .
The Junos PyEZ library has been tested with Python versions 2.6 and 2.7.
At the time of this writing PyEZ is not supported in Python 3.x environments. This restriction is due to dependencies on other Python modules, such as ncclient, that do not support Python 3.x.
- Junos PyEZ maintains a "timeout" mechanism for each executed command and response pair. The default timeout is 30 seconds. You can override the default by using the Device.timeout property. If a timeout does occur, a timeout exception is raised.
- Some devices running Junos OS might disconnect the NETCONF session due to inactivity. This behavior has been observed on SRX Series Services Gateways. In such cases, an exception is raised upon execution of the next command. The Junos PyEZ library does not reconnect to the device in these inactivity scenarios. However, you can call Device.open() to reconnect.
- Command execution is synchronous and blocking. The underlying NETCONF transport library is the ncclient module. If your application requires asynchronous or nonblocking execution logic, you should investigate other libraries to wrap around the PyEZ framework such as Twisted or Python Threads.
- The
Device.cli()
method is intended to be used with interactive python, and as a means to facilitate the interactive experience as needed. Please do not use this for "screen-scraping" the CLI output for automation purposes.
A couple software version-dependent limitations that must be noted:
- 11.4 - This is the first release where the Junos XML API supports the ability to retrieve the command output in text (CLI) format. Prior to Junos OS Release 11.4, the response output was in XML. If you use the Device.cli() feature, note that this only works with Junos OS Release 11.4 and later releases.
- 11.4 - This is the first release where the Junos XML API supports the ability to load configuration changes using Junos OS set commands.
For devices with multiple Routing Engines, you can only connect to the primary Routing Engine. If you attempt to connect to the backup Routing Engine, the Device.open() method fails with an exception.
The primary restriction is on software-install functionality provided by the jnpr.junos.utils.sw module. The software-install process is currently designed to support simple deployment scenarios. The expected use case for this software is deploying new equipment. The following scenarios are supported:
- Standalone devices with a single Routing Engine, for example EX4200 switches
- Standalone devices equipped with dual Routing Engines, for example MX960 routers
- EX Series Virtual Chassis in non-mixed-mode configurations (all devices use the same Junos OS software package)
- Deployment configurations that do not have any form of "in-service" features enabled, such as unified ISSU and NSSU.
The following scenarios are known not to be supported:
- SRX Series chassis clusters
- EX Series Virtual Chassis in mixed-mode configurations (devices use different Junos OS software packages)
- Virtual Chassis Fabric (VCF)
- MX Series Virtual Chassis
- Any deployments with "in-service" configurations enabled (such as unified ISSU or NSSU)