A not-very-minimal reproduction for grpc/grpc-node#2502.
In the wild we've seen NodeJS PubSub publishers get "stuck" and continually report DEADLINE_EXCEEDED errors until the process is restarted. Much investigation later, this appears to be related to a sequence of:
- NodeJS client begins to create a TLS session. The handshake gets to the client receiving
ServerHello
. - Something (other event loop work, starved cpu) prevents NodeJS from completing the TLS handshake
- Server-side times out the TLS connection after 10s sends
FIN,ACK
- NodeJS frees up, continues TLS handshake by sending
ChangeCipherSpec,Finished
- Server-side sends
RST
- NodeJS somehow thinks the TLS session is valid (??)
This code reproduces by...
Server-side: A partially implemented PubSub gRPC server with an outrageously short connection timeout of 1 millisecond.
Client-side: Try publishing a message every 500ms. Every 1ms, add some numbers together to simulate other processing.
We're using self-signed certificates. Run ./cert/generate.sh
which generates certs with the openssl cli. Hopefully that leaves the certificates in ./cert/
. The compose.yml
is configured to read these certificates. I'm running on Linux (Fedora 38) fwiw.
docker compose up --build
should build the container images and start them up. Most of the console output will be from the client
container. The client has grpc-js tracing turned on for transport,transport_flowctrl
.
The server is implemented in Golang to avoid using NodeJS on both ends. The compose file is set up to run three replicas of the server. I've seen this reproduce with one server container but running replicas makes it happen more quickly.
On the server-side, we're logging every call to Publish. If there are no server logs then the server isn't getting any RPCs.
On the client-side, transport_flowctrl
will log the remote (server) window size. Once you see transport_flowctrl
logging window sizes, you've reproduced. This sometimes takes a few seconds for me, but never more than a minute.
One way to tell things are broken, on the server we've set the initial window size to 1 MiB with grpc.InitialConnWindowSize
.
grpcServer := grpc.NewServer(
grpc.Creds(creds),
grpc.ConnectionTimeout(config.ConnectionTimeout),
grpc.InitialConnWindowSize(1024*1024),
grpc.KeepaliveParams(
keepalive.ServerParameters{
MaxConnectionAge: 10 * time.Second,
MaxConnectionAgeGrace: 5 * time.Second,
},
),
)
If this reproduces, the client will not be reporting the correct remote window size.
transport_flowctrl | (7) 172.24.0.3:50051 local window size: 65535 remote window size: 65472
http/2 SETTINGS frames are always sent by both endpoints at the start of a connection according to the RFC. The remote window size being wrong from the start means something's fundamentally broken.
Other evidence on the client container (docker compose exec client bash
, a few network utilities are installed):
ss -tap
won't show any TCP connections to any "sever" container ips.
tcpdump -i eth0
won't show any packets hitting the network interface
ps aux
the node process memory will slowly grow over time.
Stop the docker compose. Edit compose.yml
and in the server
service update APP_CONNECTION_TIMEOUT: "1000ms"
. Restart with docker compose up --build
On the client, transport_flowcontrol
trace logs will show "remote window size" counting down from something-near 1 MiB. "local window size" will count down from something-near 64 KiB. One of the server containers will be logging recv Publish
after every client-side transport_flowctrl
logs.
In the client container, recheck ss -tap
, tcpdump -i eth0
etc and things will appear healthy.
Note: if you make any server or client code changes, make sure to pass --build
in docker compose up --build